AO Closed Loop Requests for 20110618

    • Jun 18 00:37:24 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 00:38:25 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE done.
    • Jun 18 00:47:32 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.

  • Jun 18 02:55:55 tcs1 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 18 02:55:55 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 18 02:57:44 tcs1 LBT_AOSR: [W] PresetAO[237] failed - thGetVar ccd39.R.FRMRT.CUR error(-3606): No connection with MsgD
    • Jun 18 02:57:44 tcs1 LBT_AOSR: AOSR:PresetAO execution time: 109137 ms from IIF, handle 240
  • Jun 18 02:59:40 tcs2 LBT_IIF: irc:PresetTelescope command status: FAILED
02:57:44 PresetAO[237] failed - thGetVar ccd39.R.FRMRT.CUR error(-3606): No connection with MsgD

  • Jun 18 03:02:56 tcs1 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 18 03:02:56 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 18 03:03:59 tcs1 LBT_AOSR: [I] PresetAO[239] complete - dx:nan dy:nan slNull: f1:Filter #1 f2:Filter #1 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 18 03:03:59 tcs1 LBT_AOSR: AOSR:PresetAO execution time: 62700 ms from IIF, handle 242
  • Jun 18 03:03:59 tcs2 LBT_IIF: irc:PresetTelescope command status: SUCCESS
03:03:59 PresetAO SUCCESS

  • Jun 18 03:05:13 tcs1 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 18 03:05:13 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 18 03:05:50 tcs1 LBT_AOSR: [I] PresetAO[241] complete - dx:nan dy:nan slNull: f1:Filter #1 f2:Filter #1 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 18 03:05:50 tcs1 LBT_AOSR: AOSR:PresetAO execution time: 37816 ms from IIF, handle 244
  • Jun 18 03:05:50 tcs2 LBT_IIF: irc:PresetTelescope command status: SUCCESS
03:05:50 PresetAO SUCCESS

  • Jun 18 03:06:27 tcs2 LBT_IIF: IIF:RunAO executed from IIF, handle 228373
    • Jun 18 03:06:27 tcs1 LBT_AOSR: AOSR:AcquireRefAO executed from IIF, handle 245
    • Jun 18 03:06:27 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:AcquireRefAO
    • Jun 18 03:06:27 tcs1 LBT_AOSR: [D] AcquireRef command received.
    • Jun 18 03:06:27 tcs1 LBT_AOSR: [I] AcquireRef[242]
    • Jun 18 03:07:12 tcs1 LBT_AOSR: [W] AcquireRef[242] failed
    • Jun 18 03:07:12 tcs1 LBT_AOSR: AOSR:AcquireRefAO execution time: 44954 ms from IIF, handle 245

03:07:12 AcquireRef[242] failed

  • Jun 18 03:07:12 tcs2 LBT_IIF: IIF:RunAO execution time: 45227 ms from IIF, handle 228373
  • Jun 18 03:07:12 tcs2 LBT_IIF: irc:RunAO command status: FAILED

03:07:12 irc:RunAO command status: FAILED

    • Jun 18 03:07:18 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 03:08:19 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE done.

  • Jun 18 03:10:30 tcs1 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 18 03:10:30 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 18 03:11:11 tcs1 LBT_AOSR: [I] PresetAO[244] complete - dx:nan dy:nan slNull: f1:Filter #1 f2:Filter #1 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 18 03:11:11 tcs1 LBT_AOSR: AOSR:PresetAO execution time: 41311 ms from IIF, handle 247
  • Jun 18 03:11:11 tcs2 LBT_IIF: irc:PresetTelescope command status: SUCCESS
03:11:11 PresetAO SUCCESS

  • Jun 18 03:13:01 tcs2 LBT_IIF: IIF:RunAO executed from IIF, handle 229056
    • Jun 18 03:13:01 tcs1 LBT_AOSR: AOSR:AcquireRefAO executed from IIF, handle 248
    • Jun 18 03:13:01 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:AcquireRefAO
    • Jun 18 03:13:01 tcs1 LBT_AOSR: [D] AcquireRef command received.
    • Jun 18 03:13:01 tcs1 LBT_AOSR: [I] AcquireRef[245]
    • Jun 18 03:13:42 tcs1 LBT_AOSR: [W] AcquireRef[245] failed
    • Jun 18 03:13:42 tcs1 LBT_AOSR: AOSR:AcquireRefAO execution time: 40544 ms from IIF, handle 248

03:13:42 AcquireRef[245] failed

  • Jun 18 03:13:42 tcs2 LBT_IIF: IIF:RunAO execution time: 40801 ms from IIF, handle 229056
  • Jun 18 03:13:42 tcs2 LBT_IIF: irc:RunAO command status: FAILED

03:13:42 irc:RunAO command status: FAILED

    • Jun 18 03:13:47 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 03:14:48 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE done.

  • Jun 18 03:16:26 tcs1 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 18 03:16:26 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 18 03:17:07 tcs1 LBT_AOSR: [I] PresetAO[247] complete - dx:nan dy:nan slNull: f1:Filter #1 f2:Filter #1 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 18 03:17:07 tcs1 LBT_AOSR: AOSR:PresetAO execution time: 41450 ms from IIF, handle 250
  • Jun 18 03:17:07 tcs2 LBT_IIF: irc:PresetTelescope command status: SUCCESS
03:17:07 PresetAO SUCCESS

  • Jun 18 03:17:58 tcs2 LBT_IIF: IIF:RunAO executed from IIF, handle 229574
    • Jun 18 03:17:58 tcs1 LBT_AOSR: AOSR:AcquireRefAO executed from IIF, handle 251
    • Jun 18 03:17:58 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:AcquireRefAO
    • Jun 18 03:17:58 tcs1 LBT_AOSR: [D] AcquireRef command received.
    • Jun 18 03:17:58 tcs1 LBT_AOSR: [I] AcquireRef[248]
    • Jun 18 03:18:48 tcs1 LBT_AOSR: [W] AcquireRef[248] failed
    • Jun 18 03:18:48 tcs1 LBT_AOSR: AOSR:AcquireRefAO execution time: 50039 ms from IIF, handle 251

03:18:48 AcquireRef[248] failed

  • Jun 18 03:18:48 tcs2 LBT_IIF: IIF:RunAO execution time: 50269 ms from IIF, handle 229574
  • Jun 18 03:18:48 tcs2 LBT_IIF: irc:RunAO command status: FAILED

03:18:48 irc:RunAO command status: FAILED

    • Jun 18 03:18:52 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 03:19:53 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE done.

  • Jun 18 03:20:36 tcs1 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 18 03:20:36 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 18 03:21:18 tcs1 LBT_AOSR: [I] PresetAO[250] complete - dx:nan dy:nan slNull: f1:Filter #1 f2:Filter #1 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 18 03:21:18 tcs1 LBT_AOSR: AOSR:PresetAO execution time: 41722 ms from IIF, handle 253
  • Jun 18 03:21:18 tcs2 LBT_IIF: irc:PresetTelescope command status: SUCCESS
03:21:18 PresetAO SUCCESS

  • Jun 18 03:21:37 tcs2 LBT_IIF: IIF:RunAO executed from IIF, handle 229957
    • Jun 18 03:21:37 tcs1 LBT_AOSR: AOSR:AcquireRefAO executed from IIF, handle 254
    • Jun 18 03:21:37 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:AcquireRefAO
    • Jun 18 03:21:37 tcs1 LBT_AOSR: [D] AcquireRef command received.
    • Jun 18 03:21:37 tcs1 LBT_AOSR: [I] AcquireRef[251]
    • Jun 18 03:22:30 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 03:22:53 tcs1 LBT_AOSR: [W] AcquireRef[251] failed
    • Jun 18 03:22:53 tcs1 LBT_AOSR: AOSR:AcquireRefAO execution time: 76419 ms from IIF, handle 254

03:22:53 AcquireRef[251] failed

  • Jun 18 03:22:53 tcs2 LBT_IIF: IIF:RunAO execution time: 76688 ms from IIF, handle 229957
  • Jun 18 03:22:53 tcs2 LBT_IIF: irc:RunAO command status: FAILED

03:22:53 irc:RunAO command status: FAILED

    • Jun 18 03:23:41 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 03:24:42 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE done.

  • Jun 18 03:25:03 tcs1 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 18 03:25:03 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 18 03:25:55 tcs1 LBT_AOSR: [I] PresetAO[253] complete - dx:nan dy:nan slNull: f1:Filter #1 f2:Filter #1 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 18 03:25:55 tcs1 LBT_AOSR: AOSR:PresetAO execution time: 51949 ms from IIF, handle 256
  • Jun 18 03:25:55 tcs2 LBT_IIF: irc:PresetTelescope command status: SUCCESS
03:25:55 PresetAO SUCCESS

  • Jun 18 03:26:39 tcs2 LBT_IIF: IIF:RunAO executed from IIF, handle 230485
    • Jun 18 03:26:39 tcs1 LBT_AOSR: AOSR:AcquireRefAO executed from IIF, handle 257
    • Jun 18 03:26:39 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:AcquireRefAO
    • Jun 18 03:26:39 tcs1 LBT_AOSR: [D] AcquireRef command received.
    • Jun 18 03:26:39 tcs1 LBT_AOSR: [I] AcquireRef[254]
    • Jun 18 03:28:15 tcs1 LBT_AOSR: [I] AcquireRef[254] complete - dx:-3.103 dy:-1.274 slNull: f1:Filter #1 f2:Filter #0 freq:990 mag:7.936 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 18 03:28:15 tcs1 LBT_AOSR: AOSR:AcquireRefAO execution time: 96174 ms from IIF, handle 257

03:28:15 AcquireRefAO SUCCESS

    • Jun 18 03:28:15 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:StartAO
    • Jun 18 03:28:16 tcs1 LBT_AOSR: [I] StartAO[255] complete
    • Jun 18 03:28:16 tcs1 LBT_AOSR: AOSR:StartAO execution time: 1276 ms from IIF, handle 258
  • Jun 18 03:28:16 tcs2 LBT_IIF: IIF:RunAO execution time: 97776 ms from IIF, handle 230485
  • Jun 18 03:28:16 tcs2 LBT_IIF: irc:RunAO command status: SUCCESS

03:28:16 RunAO SUCCESS

  • Jun 18 03:28:42 tcs2 LBT_IIF: irc:RunAO command status: FAILED

03:28:42 irc:RunAO command status: FAILED

    • Jun 18 03:29:07 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.

  • Jun 18 03:29:29 tcs1 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 18 03:29:29 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 18 03:30:08 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE done.
    • Jun 18 03:30:11 tcs1 LBT_AOSR: [W] PresetAO[257] failed - adsecarb:Illegal command for state Ready (Set focal station)
    • Jun 18 03:30:11 tcs1 LBT_AOSR: AOSR:PresetAO execution time: 41650 ms from IIF, handle 260
  • Jun 18 03:30:11 tcs2 LBT_IIF: irc:PresetTelescope command status: FAILED
03:30:11 PresetAO[257] failed - adsecarb:Illegal command for state Ready (Set focal station)

  • Jun 18 03:32:20 tcs1 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 18 03:32:20 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 18 03:32:58 tcs1 LBT_AOSR: [I] PresetAO[259] complete - dx:nan dy:nan slNull: f1:Filter #1 f2:Filter #1 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 18 03:32:58 tcs1 LBT_AOSR: AOSR:PresetAO execution time: 38205 ms from IIF, handle 262
  • Jun 18 03:33:00 tcs2 LBT_IIF: irc:PresetTelescope command status: SUCCESS
03:33:00 PresetAO SUCCESS

  • Jun 18 03:33:18 tcs2 LBT_IIF: IIF:RunAO executed from IIF, handle 231181
    • Jun 18 03:33:18 tcs1 LBT_AOSR: AOSR:AcquireRefAO executed from IIF, handle 263
    • Jun 18 03:33:18 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:AcquireRefAO
    • Jun 18 03:33:18 tcs1 LBT_AOSR: [D] AcquireRef command received.
    • Jun 18 03:33:18 tcs1 LBT_AOSR: [I] AcquireRef[260]
    • Jun 18 03:34:25 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 03:35:26 tcs1 LBT_AOSR: [I] AcquireRef[260] complete - dx:-1.025 dy:-1.737 slNull: f1:Filter #1 f2:Filter #1 freq:990 mag:7.344 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 18 03:35:26 tcs1 LBT_AOSR: AOSR:AcquireRefAO execution time: 127777 ms from IIF, handle 263

03:35:26 AcquireRefAO SUCCESS

    • Jun 18 03:35:26 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:StartAO
    • Jun 18 03:35:26 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE done.
    • Jun 18 03:35:26 tcs1 LBT_AOSR: [W] StartAO[261] failed - adsecarb:Illegal command for state Ready (Run Ao)
    • Jun 18 03:35:26 tcs1 LBT_AOSR: AOSR:StartAO execution time: 268 ms from IIF, handle 264
  • Jun 18 03:35:26 tcs2 LBT_IIF: IIF:RunAO execution time: 128442 ms from IIF, handle 231181
  • Jun 18 03:35:26 tcs2 LBT_IIF: irc:RunAO command status: FAILED

03:35:26 StartAO[261] failed - adsecarb:Illegal command for state Ready (Run Ao)

  • Jun 18 03:37:50 tcs1 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 18 03:37:50 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 18 03:38:32 tcs1 LBT_AOSR: [I] PresetAO[263] complete - dx:nan dy:nan slNull: f1:Filter #1 f2:Filter #1 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 18 03:38:32 tcs1 LBT_AOSR: AOSR:PresetAO execution time: 42297 ms from IIF, handle 266
  • Jun 18 03:38:32 tcs2 LBT_IIF: irc:PresetTelescope command status: SUCCESS
03:38:32 PresetAO SUCCESS

  • Jun 18 03:38:37 tcs2 LBT_IIF: IIF:RunAO executed from IIF, handle 231736
    • Jun 18 03:38:37 tcs1 LBT_AOSR: AOSR:AcquireRefAO executed from IIF, handle 267
    • Jun 18 03:38:37 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:AcquireRefAO
    • Jun 18 03:38:37 tcs1 LBT_AOSR: [D] AcquireRef command received.
    • Jun 18 03:38:37 tcs1 LBT_AOSR: [I] AcquireRef[264]
    • Jun 18 03:40:41 tcs1 LBT_AOSR: [I] AcquireRef[264] complete - dx:-1.553 dy:-1.658 slNull: f1:Filter #1 f2:Filter #0 freq:990 mag:7.489 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 18 03:40:41 tcs1 LBT_AOSR: AOSR:AcquireRefAO execution time: 123477 ms from IIF, handle 267

03:40:41 AcquireRefAO SUCCESS

    • Jun 18 03:40:41 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:StartAO
    • Jun 18 03:40:42 tcs1 LBT_AOSR: [I] StartAO[265] complete
    • Jun 18 03:40:42 tcs1 LBT_AOSR: AOSR:StartAO execution time: 1230 ms from IIF, handle 268
  • Jun 18 03:40:42 tcs2 LBT_IIF: IIF:RunAO execution time: 124883 ms from IIF, handle 231736
  • Jun 18 03:40:42 tcs2 LBT_IIF: irc:RunAO command status: SUCCESS

03:40:42 RunAO SUCCESS

  • Jun 18 03:43:26 tcs1 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 18 03:43:26 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 18 03:44:08 tcs1 LBT_AOSR: [I] PresetAO[267] complete - dx:nan dy:nan slNull: f1:Filter #1 f2:Filter #1 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 18 03:44:08 tcs1 LBT_AOSR: AOSR:PresetAO execution time: 42040 ms from IIF, handle 270
  • Jun 18 03:44:08 tcs2 LBT_IIF: irc:PresetTelescope command status: SUCCESS
03:44:08 PresetAO SUCCESS

  • Jun 18 03:44:21 tcs2 LBT_IIF: IIF:RunAO executed from IIF, handle 232336
    • Jun 18 03:44:21 tcs1 LBT_AOSR: AOSR:AcquireRefAO executed from IIF, handle 271
    • Jun 18 03:44:21 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:AcquireRefAO
    • Jun 18 03:44:21 tcs1 LBT_AOSR: [D] AcquireRef command received.
    • Jun 18 03:44:21 tcs1 LBT_AOSR: [I] AcquireRef[268]
    • Jun 18 03:46:01 tcs1 LBT_AOSR: [I] AcquireRef[268] complete - dx:-2.28 dy:-1.671 slNull: f1:Filter #1 f2:Filter #0 freq:990 mag:7.494 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 18 03:46:01 tcs1 LBT_AOSR: AOSR:AcquireRefAO execution time: 100117 ms from IIF, handle 271

03:46:01 AcquireRefAO SUCCESS

    • Jun 18 03:46:01 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:StartAO
    • Jun 18 03:46:02 tcs1 LBT_AOSR: [I] StartAO[269] complete
    • Jun 18 03:46:02 tcs1 LBT_AOSR: AOSR:StartAO execution time: 1224 ms from IIF, handle 272
  • Jun 18 03:46:02 tcs2 LBT_IIF: IIF:RunAO execution time: 101547 ms from IIF, handle 232336
  • Jun 18 03:46:02 tcs2 LBT_IIF: irc:RunAO command status: SUCCESS

03:46:02 RunAO SUCCESS

  • Jun 18 03:46:41 tcs1 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 18 03:46:41 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 18 03:47:23 tcs1 LBT_AOSR: [I] PresetAO[271] complete - dx:nan dy:nan slNull: f1:Filter #1 f2:Filter #1 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 18 03:47:23 tcs1 LBT_AOSR: AOSR:PresetAO execution time: 42052 ms from IIF, handle 274
  • Jun 18 03:47:23 tcs2 LBT_IIF: irc:PresetTelescope command status: SUCCESS
03:47:23 PresetAO SUCCESS

  • Jun 18 03:47:32 tcs2 LBT_IIF: IIF:RunAO executed from IIF, handle 232671
    • Jun 18 03:47:32 tcs1 LBT_AOSR: AOSR:AcquireRefAO executed from IIF, handle 275
    • Jun 18 03:47:32 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:AcquireRefAO
    • Jun 18 03:47:32 tcs1 LBT_AOSR: [D] AcquireRef command received.
    • Jun 18 03:47:32 tcs1 LBT_AOSR: [I] AcquireRef[272]
    • Jun 18 03:49:09 tcs1 LBT_AOSR: [I] AcquireRef[272] complete - dx:-2.669 dy:-1.667 slNull: f1:Filter #1 f2:Filter #0 freq:990 mag:7.605 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 18 03:49:09 tcs1 LBT_AOSR: AOSR:AcquireRefAO execution time: 97665 ms from IIF, handle 275

03:49:09 AcquireRefAO SUCCESS

    • Jun 18 03:49:10 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:StartAO
    • Jun 18 03:49:11 tcs1 LBT_AOSR: [I] StartAO[273] complete
    • Jun 18 03:49:11 tcs1 LBT_AOSR: AOSR:StartAO execution time: 1267 ms from IIF, handle 276
  • Jun 18 03:49:11 tcs2 LBT_IIF: IIF:RunAO execution time: 99198 ms from IIF, handle 232671
  • Jun 18 03:49:11 tcs2 LBT_IIF: irc:RunAO command status: SUCCESS

03:49:11 RunAO SUCCESS

  • Jun 18 03:50:21 tcs1 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 18 03:50:21 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 18 03:51:03 tcs1 LBT_AOSR: [I] PresetAO[275] complete - dx:nan dy:nan slNull: f1:Filter #1 f2:Filter #1 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 18 03:51:03 tcs1 LBT_AOSR: AOSR:PresetAO execution time: 41295 ms from IIF, handle 278
  • Jun 18 03:51:03 tcs2 LBT_IIF: irc:PresetTelescope command status: SUCCESS
03:51:03 PresetAO SUCCESS

  • Jun 18 03:51:28 tcs2 LBT_IIF: IIF:RunAO executed from IIF, handle 233084
    • Jun 18 03:51:28 tcs1 LBT_AOSR: AOSR:AcquireRefAO executed from IIF, handle 279
    • Jun 18 03:51:28 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:AcquireRefAO
    • Jun 18 03:51:28 tcs1 LBT_AOSR: [D] AcquireRef command received.
    • Jun 18 03:51:28 tcs1 LBT_AOSR: [I] AcquireRef[276]
    • Jun 18 03:52:08 tcs1 LBT_AOSR: [W] AcquireRef[276] failed
    • Jun 18 03:52:08 tcs1 LBT_AOSR: AOSR:AcquireRefAO execution time: 39782 ms from IIF, handle 279

03:52:08 AcquireRef[276] failed

  • Jun 18 03:52:08 tcs2 LBT_IIF: IIF:RunAO execution time: 40041 ms from IIF, handle 233084
  • Jun 18 03:52:08 tcs2 LBT_IIF: irc:RunAO command status: FAILED

03:52:08 irc:RunAO command status: FAILED

    • Jun 18 03:52:11 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 03:53:11 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE done.

  • Jun 18 03:54:54 tcs1 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 18 03:54:54 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 18 03:55:36 tcs1 LBT_AOSR: [I] PresetAO[278] complete - dx:nan dy:nan slNull: f1:Filter #1 f2:Filter #1 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 18 03:55:36 tcs1 LBT_AOSR: AOSR:PresetAO execution time: 42009 ms from IIF, handle 281
  • Jun 18 03:55:36 tcs2 LBT_IIF: irc:PresetTelescope command status: SUCCESS
03:55:36 PresetAO SUCCESS

  • Jun 18 03:56:00 tcs2 LBT_IIF: IIF:RunAO executed from IIF, handle 233559
    • Jun 18 03:56:01 tcs1 LBT_AOSR: AOSR:AcquireRefAO executed from IIF, handle 282
    • Jun 18 03:56:01 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:AcquireRefAO
    • Jun 18 03:56:01 tcs1 LBT_AOSR: [D] AcquireRef command received.
    • Jun 18 03:56:01 tcs1 LBT_AOSR: [I] AcquireRef[279]
    • Jun 18 03:57:30 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 03:58:30 tcs1 LBT_AOSR: [I] AcquireRef[279] complete - dx:-1.393 dy:-1.664 slNull: f1:Filter #1 f2:Filter #1 freq:990 mag:7.435 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 18 03:58:30 tcs1 LBT_AOSR: AOSR:AcquireRefAO execution time: 149456 ms from IIF, handle 282

03:58:30 AcquireRefAO SUCCESS

    • Jun 18 03:58:30 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:StartAO
    • Jun 18 03:58:30 tcs1 LBT_AOSR: [W] StartAO[280] failed - adsecarb:Illegal command for state Ready (Run Ao)
    • Jun 18 03:58:30 tcs1 LBT_AOSR: AOSR:StartAO execution time: 353 ms from IIF, handle 283
    • Jun 18 03:58:30 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE done.
  • Jun 18 03:58:31 tcs2 LBT_IIF: IIF:RunAO execution time: 150227 ms from IIF, handle 233559
  • Jun 18 03:58:31 tcs2 LBT_IIF: irc:RunAO command status: FAILED

03:58:30 StartAO[280] failed - adsecarb:Illegal command for state Ready (Run Ao)

  • Jun 18 04:00:58 tcs1 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 18 04:00:58 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 18 04:01:40 tcs1 LBT_AOSR: [I] PresetAO[282] complete - dx:nan dy:nan slNull: f1:Filter #1 f2:Filter #1 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 18 04:01:40 tcs1 LBT_AOSR: AOSR:PresetAO execution time: 41501 ms from IIF, handle 285
  • Jun 18 04:01:40 tcs2 LBT_IIF: irc:PresetTelescope command status: SUCCESS
04:01:40 PresetAO SUCCESS

  • Jun 18 04:01:48 tcs2 LBT_IIF: IIF:RunAO executed from IIF, handle 234164
    • Jun 18 04:01:49 tcs1 LBT_AOSR: AOSR:AcquireRefAO executed from IIF, handle 286
    • Jun 18 04:01:49 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:AcquireRefAO
    • Jun 18 04:01:49 tcs1 LBT_AOSR: [D] AcquireRef command received.
    • Jun 18 04:01:49 tcs1 LBT_AOSR: [I] AcquireRef[283]
    • Jun 18 04:03:24 tcs1 LBT_AOSR: [I] AcquireRef[283] complete - dx:-2.223 dy:-1.676 slNull: f1:Filter #1 f2:Filter #0 freq:990 mag:7.554 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 18 04:03:24 tcs1 LBT_AOSR: AOSR:AcquireRefAO execution time: 95089 ms from IIF, handle 286

04:03:24 AcquireRefAO SUCCESS

    • Jun 18 04:03:24 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:StartAO
    • Jun 18 04:03:25 tcs1 LBT_AOSR: [I] StartAO[284] complete
    • Jun 18 04:03:25 tcs1 LBT_AOSR: AOSR:StartAO execution time: 1220 ms from IIF, handle 287
  • Jun 18 04:03:25 tcs2 LBT_IIF: IIF:RunAO execution time: 96490 ms from IIF, handle 234164
  • Jun 18 04:03:25 tcs2 LBT_IIF: irc:RunAO command status: SUCCESS

04:03:25 RunAO SUCCESS

    • Jun 18 04:04:31 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
  • Jun 18 04:04:48 tcs2 LBT_IIF: irc:PresetTelescope command status: FAILED
04:04:48 irc:PresetTelescope command status: FAILED

    • Jun 18 04:05:32 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE done.

  • Jun 18 04:08:52 tcs1 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 18 04:08:52 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
  • Jun 18 04:09:10 tcs2 LBT_IIF: irc:PresetTelescope command status: FAILED
04:09:10 irc:PresetTelescope command status: FAILED

    • Jun 18 04:09:33 tcs1 LBT_AOSR: [I] PresetAO[287] complete - dx:nan dy:nan slNull: f1:Filter #1 f2:Filter #1 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 18 04:09:33 tcs1 LBT_AOSR: AOSR:PresetAO execution time: 41426 ms from IIF, handle 290

  • Jun 18 04:24:43 tcs1 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 18 04:24:43 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 18 04:25:22 tcs1 LBT_AOSR: [I] PresetAO[290] complete - dx:nan dy:nan slNull: f1:Filter #1 f2:Filter #1 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 18 04:25:22 tcs1 LBT_AOSR: AOSR:PresetAO execution time: 38414 ms from IIF, handle 293
  • Jun 18 04:25:38 tcs2 LBT_IIF: irc:PresetTelescope command status: SUCCESS
04:25:38 PresetAO SUCCESS

  • Jun 18 04:26:48 tcs2 LBT_IIF: IIF:RunAO executed from IIF, handle 236773
    • Jun 18 04:26:48 tcs1 LBT_AOSR: AOSR:AcquireRefAO executed from IIF, handle 294
    • Jun 18 04:26:48 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:AcquireRefAO
    • Jun 18 04:26:48 tcs1 LBT_AOSR: [D] AcquireRef command received.
    • Jun 18 04:26:48 tcs1 LBT_AOSR: [I] AcquireRef[291]
    • Jun 18 04:27:38 tcs1 LBT_AOSR: [W] AcquireRef[291] failed
    • Jun 18 04:27:38 tcs1 LBT_AOSR: AOSR:AcquireRefAO execution time: 49332 ms from IIF, handle 294

04:27:38 AcquireRef[291] failed

  • Jun 18 04:27:38 tcs2 LBT_IIF: IIF:RunAO execution time: 49603 ms from IIF, handle 236773
  • Jun 18 04:27:38 tcs2 LBT_IIF: irc:RunAO command status: FAILED

04:27:38 irc:RunAO command status: FAILED

    • Jun 18 04:27:40 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 04:30:26 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 04:31:25 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE done.

  • Jun 18 04:33:12 tcs1 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 18 04:33:12 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 18 04:33:53 tcs1 LBT_AOSR: [I] PresetAO[293] complete - dx:nan dy:nan slNull: f1:Filter #1 f2:Filter #1 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 18 04:33:53 tcs1 LBT_AOSR: AOSR:PresetAO execution time: 41426 ms from IIF, handle 296
  • Jun 18 04:33:53 tcs2 LBT_IIF: irc:PresetTelescope command status: SUCCESS
04:33:53 PresetAO SUCCESS

  • Jun 18 04:34:07 tcs2 LBT_IIF: IIF:RunAO executed from IIF, handle 237537
    • Jun 18 04:34:07 tcs1 LBT_AOSR: AOSR:AcquireRefAO executed from IIF, handle 297
    • Jun 18 04:34:07 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:AcquireRefAO
    • Jun 18 04:34:07 tcs1 LBT_AOSR: [D] AcquireRef command received.
    • Jun 18 04:34:07 tcs1 LBT_AOSR: [I] AcquireRef[294]
    • Jun 18 04:35:44 tcs1 LBT_AOSR: [I] AcquireRef[294] complete - dx:-4.035 dy:-1.544 slNull: f1:Filter #1 f2:Filter #0 freq:990 mag:8.223 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 18 04:35:44 tcs1 LBT_AOSR: AOSR:AcquireRefAO execution time: 97103 ms from IIF, handle 297

04:35:44 AcquireRefAO SUCCESS

    • Jun 18 04:35:44 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:StartAO
    • Jun 18 04:35:45 tcs1 LBT_AOSR: [I] StartAO[295] complete
    • Jun 18 04:35:45 tcs1 LBT_AOSR: AOSR:StartAO execution time: 1225 ms from IIF, handle 298
  • Jun 18 04:35:45 tcs2 LBT_IIF: IIF:RunAO execution time: 98495 ms from IIF, handle 237537
  • Jun 18 04:35:45 tcs2 LBT_IIF: irc:RunAO command status: SUCCESS

04:35:45 RunAO SUCCESS

  • Jun 18 04:36:07 tcs1 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 18 04:36:07 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 18 04:36:49 tcs1 LBT_AOSR: [I] PresetAO[297] complete - dx:nan dy:nan slNull: f1:Filter #1 f2:Filter #1 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 18 04:36:49 tcs1 LBT_AOSR: AOSR:PresetAO execution time: 41879 ms from IIF, handle 300
  • Jun 18 04:36:49 tcs2 LBT_IIF: irc:PresetTelescope command status: SUCCESS
04:36:49 PresetAO SUCCESS

  • Jun 18 04:36:57 tcs2 LBT_IIF: IIF:RunAO executed from IIF, handle 237836
    • Jun 18 04:36:57 tcs1 LBT_AOSR: AOSR:AcquireRefAO executed from IIF, handle 301
    • Jun 18 04:36:57 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:AcquireRefAO
    • Jun 18 04:36:57 tcs1 LBT_AOSR: [D] AcquireRef command received.
    • Jun 18 04:36:57 tcs1 LBT_AOSR: [I] AcquireRef[298]
    • Jun 18 04:38:51 tcs1 LBT_AOSR: [I] AcquireRef[298] complete - dx:-4.488 dy:-1.491 slNull: f1:Filter #1 f2:Filter #0 freq:990 mag:8.297 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 18 04:38:51 tcs1 LBT_AOSR: AOSR:AcquireRefAO execution time: 114003 ms from IIF, handle 301

04:38:51 AcquireRefAO SUCCESS

    • Jun 18 04:38:51 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:StartAO
    • Jun 18 04:38:52 tcs1 LBT_AOSR: [I] StartAO[299] complete
    • Jun 18 04:38:52 tcs1 LBT_AOSR: AOSR:StartAO execution time: 1238 ms from IIF, handle 302
  • Jun 18 04:38:52 tcs2 LBT_IIF: IIF:RunAO execution time: 115403 ms from IIF, handle 237836
  • Jun 18 04:38:52 tcs2 LBT_IIF: irc:RunAO command status: SUCCESS

04:38:52 RunAO SUCCESS

    • Jun 18 04:39:08 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.

  • Jun 18 04:39:30 tcs1 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 18 04:39:30 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 18 04:40:12 tcs1 LBT_AOSR: [W] PresetAO[301] failed - adsecarb:Illegal command for state Ready (Set focal station)
    • Jun 18 04:40:12 tcs1 LBT_AOSR: AOSR:PresetAO execution time: 42180 ms from IIF, handle 304
  • Jun 18 04:40:12 tcs2 LBT_IIF: irc:PresetTelescope command status: FAILED
04:40:12 PresetAO[301] failed - adsecarb:Illegal command for state Ready (Set focal station)

    • Jun 18 04:49:56 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 04:50:56 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE done.

  • Jun 18 04:54:08 tcs1 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 18 04:54:08 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 18 04:54:46 tcs1 LBT_AOSR: [I] PresetAO[303] complete - dx:nan dy:nan slNull: f1:Filter #1 f2:Filter #1 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 18 04:54:46 tcs1 LBT_AOSR: AOSR:PresetAO execution time: 38218 ms from IIF, handle 306
  • Jun 18 04:54:58 tcs2 LBT_IIF: irc:PresetTelescope command status: SUCCESS
04:54:58 PresetAO SUCCESS

  • Jun 18 04:55:10 tcs2 LBT_IIF: IIF:RunAO executed from IIF, handle 239733
    • Jun 18 04:55:10 tcs1 LBT_AOSR: AOSR:AcquireRefAO executed from IIF, handle 307
    • Jun 18 04:55:10 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:AcquireRefAO
    • Jun 18 04:55:10 tcs1 LBT_AOSR: [D] AcquireRef command received.
    • Jun 18 04:55:10 tcs1 LBT_AOSR: [I] AcquireRef[304]
    • Jun 18 04:55:52 tcs1 LBT_AOSR: [W] AcquireRef[304] failed
    • Jun 18 04:55:52 tcs1 LBT_AOSR: AOSR:AcquireRefAO execution time: 41990 ms from IIF, handle 307

04:55:52 AcquireRef[304] failed

  • Jun 18 04:55:52 tcs2 LBT_IIF: IIF:RunAO execution time: 42248 ms from IIF, handle 239733
  • Jun 18 04:55:52 tcs2 LBT_IIF: irc:RunAO command status: FAILED

04:55:52 irc:RunAO command status: FAILED

    • Jun 18 04:55:55 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 04:56:54 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE done.

  • Jun 18 04:59:17 tcs1 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 18 04:59:17 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 18 05:00:00 tcs1 LBT_AOSR: [I] PresetAO[306] complete - dx:nan dy:nan slNull: f1:Filter #1 f2:Filter #1 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 18 05:00:00 tcs1 LBT_AOSR: AOSR:PresetAO execution time: 42148 ms from IIF, handle 309
  • Jun 18 05:00:00 tcs2 LBT_IIF: irc:PresetTelescope command status: SUCCESS
05:00:00 PresetAO SUCCESS

  • Jun 18 05:00:06 tcs2 LBT_IIF: IIF:RunAO executed from IIF, handle 240252
    • Jun 18 05:00:07 tcs1 LBT_AOSR: AOSR:AcquireRefAO executed from IIF, handle 310
    • Jun 18 05:00:07 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:AcquireRefAO
    • Jun 18 05:00:07 tcs1 LBT_AOSR: [D] AcquireRef command received.
    • Jun 18 05:00:07 tcs1 LBT_AOSR: [I] AcquireRef[307]
    • Jun 18 05:01:40 tcs1 LBT_AOSR: [I] AcquireRef[307] complete - dx:-1.44 dy:-1.714 slNull: f1:Filter #1 f2:Filter #1 freq:990 mag:7.395 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 18 05:01:40 tcs1 LBT_AOSR: AOSR:AcquireRefAO execution time: 93333 ms from IIF, handle 310

05:01:40 AcquireRefAO SUCCESS

    • Jun 18 05:01:40 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:StartAO
    • Jun 18 05:01:41 tcs1 LBT_AOSR: [I] StartAO[308] complete
    • Jun 18 05:01:41 tcs1 LBT_AOSR: AOSR:StartAO execution time: 1237 ms from IIF, handle 311
  • Jun 18 05:01:41 tcs2 LBT_IIF: IIF:RunAO execution time: 94816 ms from IIF, handle 240252
  • Jun 18 05:01:41 tcs2 LBT_IIF: irc:RunAO command status: SUCCESS

05:01:41 RunAO SUCCESS

    • Jun 18 05:05:34 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.

  • Jun 18 05:05:57 tcs1 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 18 05:05:57 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 18 05:06:38 tcs1 LBT_AOSR: [W] PresetAO[310] failed - adsecarb:Illegal command for state Ready (Set focal station)
    • Jun 18 05:06:38 tcs1 LBT_AOSR: AOSR:PresetAO execution time: 41869 ms from IIF, handle 313
  • Jun 18 05:06:38 tcs2 LBT_IIF: irc:PresetTelescope command status: FAILED
05:06:38 PresetAO[310] failed - adsecarb:Illegal command for state Ready (Set focal station)

    • Jun 18 05:08:15 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 05:09:38 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 05:10:39 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE done.

  • Jun 18 06:05:54 tcs1 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 18 06:05:54 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 18 06:06:54 tcs1 LBT_AOSR: [I] PresetAO[316] complete - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:312 mag:0 nBins:4 nModes:36 r0:0 snMode:0 strehl:0 ttMod:6
    • Jun 18 06:06:54 tcs1 LBT_AOSR: AOSR:PresetAO execution time: 60530 ms from IIF, handle 319
  • Jun 18 06:06:54 tcs2 LBT_IIF: irc:PresetTelescope command status: SUCCESS
06:06:54 PresetAO SUCCESS

  • Jun 18 06:08:34 tcs1 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 18 06:08:34 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 18 06:09:09 tcs1 LBT_AOSR: [I] PresetAO[318] complete - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:312 mag:0 nBins:4 nModes:36 r0:0 snMode:0 strehl:0 ttMod:6
    • Jun 18 06:09:09 tcs1 LBT_AOSR: AOSR:PresetAO execution time: 35681 ms from IIF, handle 321
  • Jun 18 06:09:09 tcs2 LBT_IIF: irc:PresetTelescope command status: SUCCESS
06:09:09 PresetAO SUCCESS

  • Jun 18 06:11:30 tcs2 LBT_IIF: IIF:RunAO executed from IIF, handle 247696
    • Jun 18 06:11:31 tcs1 LBT_AOSR: AOSR:AcquireRefAO executed from IIF, handle 322
    • Jun 18 06:11:31 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:AcquireRefAO
    • Jun 18 06:11:31 tcs1 LBT_AOSR: [D] AcquireRef command received.
    • Jun 18 06:11:31 tcs1 LBT_AOSR: [I] AcquireRef[319]
    • Jun 18 06:12:49 tcs1 LBT_AOSR: [W] AcquireRef[319] failed
    • Jun 18 06:12:49 tcs1 LBT_AOSR: AOSR:AcquireRefAO execution time: 78370 ms from IIF, handle 322

06:12:49 AcquireRef[319] failed

  • Jun 18 06:12:49 tcs2 LBT_IIF: IIF:RunAO execution time: 78713 ms from IIF, handle 247696
  • Jun 18 06:12:49 tcs2 LBT_IIF: irc:RunAO command status: FAILED

06:12:49 irc:RunAO command status: FAILED

    • Jun 18 06:12:51 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 06:13:52 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE done.
    • Jun 18 07:37:59 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 07:42:01 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 07:43:47 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 07:44:47 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE done.
    • Jun 18 07:58:13 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 07:59:13 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE done.

  • Jun 18 08:39:47 tcs1 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 18 08:39:47 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 18 08:40:54 tcs1 LBT_AOSR: [I] PresetAO[324] complete - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:312 mag:0 nBins:4 nModes:36 r0:0 snMode:0 strehl:0 ttMod:6
    • Jun 18 08:40:54 tcs1 LBT_AOSR: AOSR:PresetAO execution time: 67738 ms from IIF, handle 327
  • Jun 18 08:40:54 tcs2 LBT_IIF: irc:PresetTelescope command status: SUCCESS
08:40:54 PresetAO SUCCESS

  • Jun 18 08:43:01 tcs2 LBT_IIF: IIF:RunAO executed from IIF, handle 263639
    • Jun 18 08:43:01 tcs1 LBT_AOSR: AOSR:AcquireRefAO executed from IIF, handle 328
    • Jun 18 08:43:01 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:AcquireRefAO
    • Jun 18 08:43:01 tcs1 LBT_AOSR: [D] AcquireRef command received.
    • Jun 18 08:43:01 tcs1 LBT_AOSR: [I] AcquireRef[325]
    • Jun 18 08:44:04 tcs1 LBT_AOSR: [W] AcquireRef[325] failed - RETRY: source_acq error: Star centering procedure failed to converge after 5 iterations (-20003) WFSARB_STAR_NOTCONVERGED
    • Jun 18 08:44:04 tcs1 LBT_AOSR: AOSR:AcquireRefAO execution time: 63178 ms from IIF, handle 328

08:44:04 AcquireRef[325] failed - RETRY: source_acq error: Star centering procedure failed to converge after 5 iterations (-20003) WFSARB_STAR_NOTCONVERGED

  • Jun 18 08:44:04 tcs2 LBT_IIF: IIF:RunAO execution time: 63434 ms from IIF, handle 263639
  • Jun 18 08:44:04 tcs2 LBT_IIF: irc:RunAO command status: FAILED

08:44:04 irc:RunAO command status: FAILED

  • Jun 18 08:46:01 tcs2 LBT_IIF: IIF:RunAO executed from IIF, handle 264097
    • Jun 18 08:46:01 tcs1 LBT_AOSR: AOSR:AcquireRefAO executed from IIF, handle 329
    • Jun 18 08:46:01 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:AcquireRefAO
    • Jun 18 08:46:01 tcs1 LBT_AOSR: [D] AcquireRef command received.
    • Jun 18 08:46:01 tcs1 LBT_AOSR: [I] AcquireRef[326]
    • Jun 18 08:48:54 tcs1 LBT_AOSR: [I] AcquireRef[326] complete - dx:0.617 dy:2.879 slNull: f1:Filter #0 f2:Filter #0 freq:400 mag:13.512 nBins:3 nModes:66 r0:0 snMode:0 strehl:0 ttMod:6
    • Jun 18 08:48:54 tcs1 LBT_AOSR: AOSR:AcquireRefAO execution time: 173492 ms from IIF, handle 329

08:48:54 AcquireRefAO SUCCESS

    • Jun 18 08:48:54 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:StartAO
    • Jun 18 08:48:56 tcs1 LBT_AOSR: [I] StartAO[327] complete
    • Jun 18 08:48:56 tcs1 LBT_AOSR: AOSR:StartAO execution time: 1221 ms from IIF, handle 330
  • Jun 18 08:48:56 tcs2 LBT_IIF: IIF:RunAO execution time: 174969 ms from IIF, handle 264097
  • Jun 18 08:48:56 tcs2 LBT_IIF: irc:RunAO command status: SUCCESS

08:48:56 RunAO SUCCESS

    • Jun 18 09:00:56 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 09:02:41 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE done.
  • Jun 18 09:06:24 tcs2 LBT_IIF: IIF:RunAO executed from IIF, handle 267778
    • Jun 18 09:06:24 tcs1 LBT_AOSR: AOSR:AcquireRefAO executed from IIF, handle 332
    • Jun 18 09:06:24 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:AcquireRefAO
    • Jun 18 09:06:24 tcs1 LBT_AOSR: [D] AcquireRef command received.
    • Jun 18 09:06:24 tcs1 LBT_AOSR: [I] AcquireRef[329]
    • Jun 18 09:08:11 tcs1 LBT_AOSR: [I] AcquireRef[329] complete - dx:-0.01 dy:0.279 slNull: f1:Filter #0 f2:Filter #0 freq:312 mag:13.861 nBins:3 nModes:66 r0:0 snMode:0 strehl:0 ttMod:6
    • Jun 18 09:08:11 tcs1 LBT_AOSR: AOSR:AcquireRefAO execution time: 107208 ms from IIF, handle 332

09:08:11 AcquireRefAO SUCCESS

    • Jun 18 09:08:11 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:StartAO
    • Jun 18 09:08:12 tcs1 LBT_AOSR: [I] StartAO[330] complete
    • Jun 18 09:08:12 tcs1 LBT_AOSR: AOSR:StartAO execution time: 1256 ms from IIF, handle 333
  • Jun 18 09:08:12 tcs2 LBT_IIF: IIF:RunAO execution time: 108629 ms from IIF, handle 267778
  • Jun 18 09:08:12 tcs2 LBT_IIF: irc:RunAO command status: SUCCESS

09:08:12 RunAO SUCCESS

  • Jun 18 09:24:57 tcs2 LBT_IIF: IIF:RunAO executed from IIF, handle 271476
    • Jun 18 09:24:58 tcs1 LBT_AOSR: AOSR:AcquireRefAO executed from IIF, handle 339
    • Jun 18 09:24:58 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:AcquireRefAO
    • Jun 18 09:24:58 tcs1 LBT_AOSR: [D] AcquireRef command received.
    • Jun 18 09:24:58 tcs1 LBT_AOSR: [I] AcquireRef[336]
    • Jun 18 09:26:54 tcs1 LBT_AOSR: [I] AcquireRef[336] complete - dx:0.38 dy:-1.641 slNull: f1:Filter #0 f2:Filter #0 freq:312 mag:13.986 nBins:3 nModes:66 r0:0 snMode:0 strehl:0 ttMod:6
    • Jun 18 09:26:54 tcs1 LBT_AOSR: AOSR:AcquireRefAO execution time: 116816 ms from IIF, handle 339

09:26:54 AcquireRefAO SUCCESS

    • Jun 18 09:26:54 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:StartAO
    • Jun 18 09:26:56 tcs1 LBT_AOSR: [I] StartAO[337] complete
    • Jun 18 09:26:56 tcs1 LBT_AOSR: AOSR:StartAO execution time: 1218 ms from IIF, handle 340
  • Jun 18 09:26:56 tcs2 LBT_IIF: IIF:RunAO execution time: 118224 ms from IIF, handle 271476
  • Jun 18 09:26:56 tcs2 LBT_IIF: irc:RunAO command status: SUCCESS

09:26:56 RunAO SUCCESS

    • Jun 18 09:36:09 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 09:37:10 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE done.
    • Jun 18 10:28:58 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 10:29:57 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE done.
    • Jun 18 10:40:43 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 10:42:26 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE done.
    • Jun 18 10:48:28 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 10:49:29 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE done.
    • Jun 18 10:50:52 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 10:51:52 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE done.
    • Jun 18 10:58:05 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 10:59:04 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE done.
    • Jun 18 11:07:34 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 11:08:34 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE done.
    • Jun 18 11:12:35 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 11:13:36 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE done.
    • Jun 18 11:22:52 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 11:23:52 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE done.
    • Jun 18 11:28:34 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 11:29:33 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE done.
    • Jun 18 11:35:58 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 11:36:57 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE done.
    • Jun 18 12:26:26 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE started.
    • Jun 18 12:27:27 tcs1 LBT_AOSR: [I] Adsec 672a-right recovery from FAILURE done.

  • Jun 18 23:42:27 tcs1 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 18 23:42:27 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 18 23:42:55 tcs1 LBT_AOSR: [W] PresetAO[343] failed - Timeout waiting for ccd39.R.REP.CUR (-5001) TIMEOUT_ERROR
    • Jun 18 23:42:55 tcs1 LBT_AOSR: AOSR:PresetAO execution time: 28895 ms from IIF, handle 346
  • Jun 18 23:45:44 tcs2 LBT_IIF: irc:PresetTelescope command status: FAILED
23:42:55 PresetAO[343] failed - Timeout waiting for ccd39.R.REP.CUR (-5001) TIMEOUT_ERROR

  • Jun 18 23:49:32 tcs1 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 18 23:49:32 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 18 23:50:28 tcs1 LBT_AOSR: [W] PresetAO[345] failed - Timeout waiting for ccd39.R.ENABLE.CUR (-5001) TIMEOUT_ERROR
    • Jun 18 23:50:28 tcs1 LBT_AOSR: AOSR:PresetAO execution time: 55237 ms from IIF, handle 348
  • Jun 18 23:50:28 tcs2 LBT_IIF: irc:PresetTelescope command status: FAILED
23:50:28 PresetAO[345] failed - Timeout waiting for ccd39.R.ENABLE.CUR (-5001) TIMEOUT_ERROR

  • Jun 18 23:55:52 tcs1 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 18 23:55:52 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 18 23:57:53 tcs1 LBT_AOSR: [W] PresetAO[347] failed - Command timeout - -13107: Arbitrator interface generic error
    • Jun 18 23:57:53 tcs1 LBT_AOSR: AOSR:PresetAO execution time: 120399 ms from IIF, handle 350
  • Jun 18 23:57:53 tcs2 LBT_IIF: irc:PresetTelescope command status: FAILED
23:57:53 PresetAO[347] failed - Command timeout - -13107: Arbitrator interface generic error

  • Jun 18 23:58:18 tcs1 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 18 23:58:18 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 18 23:58:56 tcs1 LBT_AOSR: [I] PresetAO[349] complete - dx:nan dy:nan slNull: f1:Filter #1 f2:Filter #1 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 18 23:58:56 tcs1 LBT_AOSR: AOSR:PresetAO execution time: 38380 ms from IIF, handle 352
  • Jun 18 23:58:56 tcs2 LBT_IIF: irc:PresetTelescope command status: SUCCESS
23:58:56 PresetAO SUCCESS

  • Jun 18 23:59:49 tcs2 LBT_IIF: IIF:RunAO executed from IIF, handle 359105
    • Jun 18 23:59:49 tcs1 LBT_AOSR: AOSR:AcquireRefAO executed from IIF, handle 353
    • Jun 18 23:59:49 tcs1 LBT_AOSR: [T] AOSCommands got: AOS:AcquireRefAO
    • Jun 18 23:59:49 tcs1 LBT_AOSR: [D] AcquireRef command received.
    • Jun 18 23:59:49 tcs1 LBT_AOSR: [I] AcquireRef[350]
    • Jun 18 23:59:55 tcs1 LBT_AOSR: [W] AcquireRef[350] failed - RETRY: No stars found in TV frame (-20001) WFSARB_STAR_NOTFOUND
    • Jun 18 23:59:55 tcs1 LBT_AOSR: AOSR:AcquireRefAO execution time: 5642 ms from IIF, handle 353

23:59:55 AcquireRef[350] failed - RETRY: No stars found in TV frame (-20001) WFSARB_STAR_NOTFOUND

  • Jun 18 23:59:55 tcs2 LBT_IIF: IIF:RunAO execution time: 6065 ms from IIF, handle 359105
  • Jun 18 23:59:55 tcs2 LBT_IIF: irc:RunAO command status: FAILED

23:59:55 irc:RunAO command status: FAILED

-- DougMiller - 30 Jun 2011
Topic revision: r1 - 30 Jun 2011, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback