The anemometers are located inside of the dome at the secondaries swing arms. The ASMs are using the wind speed information to trigger the TSS (thin shell safety) system. This system allows the ASM to work in a regime when it is too much wind speed. The actual setting is 20m/s, and this is the limit to close the dome.

The TSS can be enabled/disabled if the Shell is in Rest or Set position.

The susbprocess anemomenter controlled by the adsec software can be seein the figure below. This process can be stopped/started any time and if can see in the log that qwe are not getting connection probably the device is having some problem. We can connect to the anemomenter and power cycle via internet.

The document in the attachement shows how to do it.

email from Kyle;
Please see the attached document which shows how to power cycle the
3D Anemometer and other devices located in the upper right tree house.
Thanks, Kyle

-- JuanGuerra - 15 Feb 2013
Topic revision: r1 - 15 Feb 2013, JuanGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.