The MasterDiagnostic process does the following:
  • wait for diagnostic records streamed at full rate (1kHz) by each ASM BCUs' to the adsec workstation
  • maintain a circular-buffer of some thousands of diagnostic records
  • forward the last record to another configurable IP address (typically the WFS workstation that uses these data to build a full diagnostic record made up of frames, slopes and ASM commands)
  • store the last record on a shared-memory area to be read by FastDiagnostic
  • on request, dump on file the last 1s of diagnostic records (DumpFast)

Source code

The following files/folder are about housekeeper:

  • $ADOPT_SOURCE/MasterDiagnostic

Configuration files

  • $ADOPT_SOURCE/conf/adsec/672a/processConf/masterdiagnostic.conf (or 672b)