Test SWBCU and firmware checks !!

System running spare SWBCU with the Marco original firmware download from the "good" SWBCU

WFS power on Ok. Adsec Flat. Instrument authorize: RETROREFF M3 position: Global offset: 172,349,0,0 Abosulte position: -386,679,0,-25.83 Hexapod position: Global Offset: 1.89,2.22,5.05,-385,295,0 Hexapod position:1.89,2.22,5.05,384.99,295.98,0

close the loop the CCD39 freeze and it seems that we are not talking with the slope comuter.. The slope computer process was restarted and we close the loop with the same freeze CCD39 From the WFSCounter we don't see any frames gouing to the secondary

Restart WFS power off, w_stop/start

Stage position: x=-77.3, y=-49.5,z=40.0

The CCD39 freeze

wfsarb.R |INF| 112|2014-02-18 20:22:44.453317| WFS > Command returns success . wfsarb.R |INF| 113|2014-02-18 20:22:44.453335| MASTDIAGN > Executing closeLoop... wfsarb.R |INF| 114|2014-02-18 20:22:44.453451| COMMANDHANDLER > Command CloseLoop (code 2008) successfully completed

mirrorctrl.R |ERR| 162|2014-02-18 20:15:36.344721| BCUCOMMANDHANDLE > Client timed-out: impossible to attach to the shared memory ! mirrorctrl.R |ERR| 163|2014-02-18 20:15:36.344760| BCUCOMMANDHANDLE > BcuCommandHandler::handleBcuRequest: REQUEST FAILED mirrorctrl.R |ERR| 164|2014-02-18 20:15:51.376513| BCUCOMMANDHANDLE > Client timed-out: impossible to attach to the shared memory ! mirrorctrl.R |ERR| 165|2014-02-18 20:15:51.376556| BCUCOMMANDHANDLE > BcuCommandHandler::handleBcuRequest: REQUEST FAILED

mirrorctrl.R |ERR| 166|2014-02-18 20:16:23.414817| MAIN > ****** FAILED PACKET FROM BCU 1 ***** mirrorctrl.R |ERR| 167|2014-02-18 20:16:23.416073| BCUCOMMANDHANDLE > BcuCommandHandler::handleBcuReply: REQUEST COMPLETED but FAILED frown, sad smile mirrorctrl.R |ERR| 168|2014-02-18 20:16:23.416169| BCUCOMMANDHANDLE > Client timed-out: impossible to attach to the shared memory ! mirrorctrl.R |ERR| 169|2014-02-18 20:16:23.416193| BCUCOMMANDHANDLE > BcuCommandHandler::handleBcuRequest: REQUEST FAILED mirrorctrl.R |INF| 170|2014-02-18 20:16:26.169542| MAIN > mirrorctrl.R |INF| 171|2014-02-18 20:16:26.169628| MAIN > --->> MirrorCtrl: changeTechViewerFrameSizeHdlr

slopecompctrl.R |INF| 181|2014-02-18 20:22:01.053714| MAIN > DSP started slopecompctrl.R |INF| 182|2014-02-18 20:22:01.054063| MAIN > Masterdiagnostic decimation set to 1 slopecompctrl.R |INF| 183|2014-02-18 20:22:14.784629| MAIN > Setting dark to /home/aoacct/AO/current//calib//wfs/current/ccd39/backgrounds/bin1/20140218_202214.fits slopecompctrl.R |INF| 184|2014-02-18 20:22:14.999764| MAIN > Dark set to /home/aoacct/AO/current//calib//wfs/current/ccd39/backgrounds/bin1/20140218_202214.fits slopecompctrl.R |INF| 185|2014-02-18 20:22:28.002137| MAIN > Setting dark to /home/aoacct/AO/current//calib//wfs/current/ccd39/backgrounds/bin1/20140218_202228_antidrift.fits slopecompctrl.R |INF| 186|2014-02-18 20:22:28.217574| MAIN > Dark set to /home/aoacct/AO/current//calib//wfs/current/ccd39/backgrounds/bin1/20140218_202228_antidrift.fits slopecompctrl.R |INF| 187|2014-02-18 20:22:43.329786| MAIN > Changing disturbance 0 slopecompctrl.R |INF| 188|2014-02-18 20:22:43.330359| MAIN > DSP stopped slopecompctrl.R |INF| 189|2014-02-18 20:22:43.333212| MAIN > DSP started slopecompctrl.R |INF| 190|2014-02-18 20:22:44.340051| MAIN > Enabling fastlink

ERROR:

wfsarb.R |INF| 135|2014-02-18 20:27:55.198344| MAIN > Processing alert 3002 (Error) from slopecompctrl.R: LOST COMMUNICATION WITH SLOPE COMPUTER

SPOT FOUND WITH M3 FOR LUCIFER2

M3: GLOBAL OFFSET: -200,250,0,0 ABSOULTE POSITION: -757 580

HEXAPOD: GLOBAL OFFSET: 0.3,2.2 5.01 -420 -25.2 0 PLATFORM POSITION 0.3 2.1 5.07 -429 -25 0

lUCIFER 2 IMAGES: luci2.20140219.0009.fits DEFOCUSED 3.0 luci2.20140219.0007.fits MOVE Rx to - luci2.20140219.0007.fits

-- JuanGuerra - 20 Feb 2014
Topic revision: r1 - 20 Feb 2014, JuanGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback