AO SDT on 06 November 2011 UT

Observer(s):C. Arcidiacono, F. Manucci, J. Argamedo, E. Pinna, A.Skemer,JC. Guerra (LBTO)

Telescope Operator: D. Huerta (LBTO)

SW Support: T. Sargent (Tucson)

Telescope Support: M. Midkiff (LBTO)

Instrument Support: J. Morris (LBTO)

Summary

Dome not open. Lost the night.
Not observing due to bad weather and ice on the top. 
Humidity:98%
Temperature outside:-7
Retro-reflector ON.
Dome darks of 600 seconds, corquad checks. Led off.Telescope zenith, lights off.
Dome darks of 600 seconds, corquad checks. Led on.Telescope zenith, lights on.
Awake up of the WFS unit. And test closing the loop.

Details

Test with the observe routines.

Align of the WFS and test with the retro-reflector. The W-Unit is working through the AOS to open/close the loop. durong the test of the close loop running the autogain, the system open the loop due to 100% skip frames, this cause that the AOS remains in loop closed when the Secondary in set AOset (loop open) after a coomand stop_ao. Issue track 3787.

It has been running many test closing the loop using the AOS.

-- JuanGuerra - 06 Nov 2011