Summary

Dome closed because of high winds.
Worked with the simulated star configuration - sending iif presets and debugging the AO software

Details

23:25 Switcing the software so that we can work with the retroreflector
  • last wind measurement 28m/s

23:42 iif_preset, test, MODE=ACE, GS=1, RS=0, PA=0
  • preset failed - BCU blocked
  • err = Resmsg[2] = Timeout waiting for ccd39.R.REP.CUR (-5001) TIMEOUT_ERROR
  • err = Resmsg[3] = PresetAO[343] failed - Timeout waiting for ccd39.R.REP.CUR (-5001) TIMEOUT_ERROR

23:46 iif_preset, test, MODE=ACE, GS=1, RS=0, PA=0
  • same error
  • err = Resmsg[2] = Timeout waiting for ccd39.R.ENABLE.CUR (-5001) TIMEOUT_ERROR
  • err = Resmsg[3] = PresetAO[345] failed - Timeout waiting for ccd39.R.ENABLE.CUR (-5001) TIMEOUT_ERROR

23:55 iif_preset, test, MODE=ACE, GS=1, RS=0, PA=0
  • failed - time out error
  • err = Resmsg[1] = Stop[346] complete
  • err = Resmsg[2] = PresetAO[347] failed - Command timeout - -13107: Arbitrator interface generic error

23:58 iif_preset, test, MODE=ACE, GS=1, RS=0, PA=0

23:59 irc_runao
  • err = Resmsg[1] = RETRY: No stars found in TV frame (-20001) WFSARB_STAR_NOTFOUND
  • err = Resmsg[2] = AcquireRef[350] failed - RETRY: No stars found in TV frame (-20001) WFSARB_STAR_NOTFOUND
  • we need to center better the hexapod to have the star in the filed

00:01 iif_preset, test, MODE=ACE, GS=1, RS=0, PA=0

00:08 iif_preset, test, MODE=ACE, GS=1, RS=0, PA=0
  • again because we don't see the star

00:14 irc_runao - failed - shell rip
  • no error reported in idl interface

00:33 iif_preset, test, MODE=ACE, GS=1, RS=0, PA=0

00:34 irc_runao - success

02:39 iif_preset, test, MODE=ACE, GS=1, RS=0, PA=0
  • did not load correct catalog - send again

02:42 iif_preset, test, MODE=ACE, GS=1, RS=0, PA=0
  • err = Resmsg[2] = thWriteVar error(-2010): Connection closed at the other end
  • err = Resmsg[3] = PresetAO[365] failed - thWriteVar error(-2010): Connection closed at the other end
  • the error has to do with the CCD

02:44 iif_preset, test, MODE=ACE, GS=1, RS=0, PA=0
  • failed - same error

02:46 iif_preset, test, MODE=ACE, GS=1, RS=0, PA=0 - success

02:47 irc_runao - success

02:49 iif_preset, test, MODE=ACE, GS=1, RS=0, PA=0 - success

02:51 irc_runao - success

02:52 iif_preset, test, MODE=ACE, GS=1, RS=0, PA=0 - failed
  • err = Resmsg[2] = adsecarb:Illegal command for state Ready (Set focal station)
  • err = Resmsg[3] = PresetAO[377] failed - adsecarb:Illegal command for state Ready (Set focal station)

03:02 iif_preset, test, MODE=ACE, GS=1, RS=0, PA=0 - success

03:03 irc_runao - success

Trying the AO software interface ONLY they have no failure... we start again giving presets.

07:36 iif_preset, test, MODE=ACE, GS=1, RS=0, PA=0 - success

07:39 irc_runao - it exits without error but the shell ripped

08:03 iif_preset, test, MODE=ACE, GS=1, RS=0, PA=0

08:05 irc_runao -failed
  • err = Resmsg[0] = RunAO result status: Error
  • err = Resmsg[1] = err = Resmsg[2] = AcquireRef[389] failed

08:30 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 - success

08:31 irc_runao - exits with no error
  • shell rip

08:37 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 - success

08:39 irc_runao
  • err = Resmsg[0] = RunAO result status: Error
  • err = Resmsg[1] = err = Resmsg[2] = AcquireRef[396] failed

08:44 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 - success

08:45 irc_runao
===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  = IDL File error
        err = Resmsg[2]  = AcquireRef[399] failed - IDL File error

08:50 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 - success

08:51 irc_runao
  • err = Resmsg[1] = IDL File error
  • err = Resmsg[2] = AcquireRef[399] failed - IDL File error

08:54 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 - success

08:55 irc_runao - success

09:03 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 - success

09:05 irc_runao
  • err = Resmsg[0] = RunAO result status: Error
  • err = Resmsg[1] = err = Resmsg[2] = AcquireRef[409] failed

09:09 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 - success

09:10 irc_runao - success

09:13 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 - failed
  • err = Resmsg[0] = PresetTelescope result status: Error
  • err = Resmsg[1] = adsecarb:Illegal command for state AOSet (TTOffload)
  • err = Resmsg[2] = Stop[414] failed - adsecarb:Illegal command for state AOSet (TTOffload)

09:17 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 - success

09:19 irc_runao - success

09:35 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 - success

09:36 irc_runao - success

09:38 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 - success

09:39 irc_runao - success

09:42 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0- success

09:43 irc_runao - success

09:46 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0- success

09:47 irc_runao - success

09:48 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao - success

09:55 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao - success

10:03 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao
 
===> Error in irc_presetTelescope
        err = Resmsg[0]  = PresetTelescope result status: Error
        err = Resmsg[1]  = Stop[443] complete
        err = Resmsg[2]  = couldn't find a star in image
===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  = right Preset inactive

10:05 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao
 ===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  = GCS right not running
  • T.O has to restart GCS

10:08 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao - success

10:10 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao - success
  • AO team has changed the oversampling frequency

10:13 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao - success
  • this one skiped after the 10 modes - but in the end the loop closed

10:17 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao - success

10:20 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao - success

10:24 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao - success
  • in this one they have put again also 'restore shape'

10:27 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao
===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  = Timeout waiting for slopecompctrl.R.DARK.CUR (-5001) TIMEOUT_ERROR
        err = Resmsg[2]  = AcquireRef[473] failed - Timeout waiting for slopecompctrl.R.DARK.CUR (-5001) TIMEOUT_ERROR
  • BCU got blocked
  • it stopped while it was loading the darks

10:32 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao - success
  • it did skip at the 10 modes - but it did not rip

10:35 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao - success

10:39 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao - * it exited without giving error at the idl interface but with a pending skip frame

10:43 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao
  • pending skip frame - no error at idl interface

10:52 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao - success

10:55 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao - success * warning DSP temperature

10:57 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao
 
===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  = AcquireRef[500] complete -  dx:-0.259 dy:0.144 slNull: f1:Filter #1 f2:Filter #0 freq:990 mag:9.465 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
        err = Resmsg[2]  = adsecarb:Illegal command for state Ready (Run Ao)
        err = Resmsg[3]  = StartAO[501] failed - adsecarb:Illegal command for state Ready (Run Ao)

11:13 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao
  • the Primary mirror was down - has to be restarted
===> Error in irc_presetTelescope
        err = Resmsg[0]  = PresetTelescope result status: Error
        err = Resmsg[1]  = Stop[502] complete
        err = Resmsg[2]  = right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
% Compiled module: IRC_RUNAO.
===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  = right Preset inactive

11:20 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao
 
===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  = AcquireRef[507] complete -  dx:-0.084 dy:0.153 slNull: f1:Filter #1 f2:Filter #0 freq:990 mag:9.471 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
        err = Resmsg[2]  = IDL Invalid/Uncoerent input parameters
        err = Resmsg[3]  = StartAO[508] failed - IDL Invalid/Uncoerent input parameters

11:30 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao
 
===> Error in irc_presetTelescope
        err = Resmsg[0]  = PresetTelescope result status: Error
        err = Resmsg[1]  = Stop[509] complete
        err = Resmsg[2]  = Attaching to shared buffer mirrorctrl.R:TECHVIEWER_65536 (-3509) BUF_NOT_AVAIL_ERROR
        err = Resmsg[3]  = PresetAO[510] failed - Attaching to shared buffer mirrorctrl.R:TECHVIEWER_65536 (-3509) BUF_NOT_AVAIL_ERROR
===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  = right Preset inactive

11:33 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao - ripped
===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  =          err = Resmsg[2]  = AcquireRef[513] failed

11:39 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao
 
===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  = adsecarb:Illegal command for state Failure (TTOffload)
        err = Resmsg[2]  = AcquireRef[516] failed - adsecarb:Illegal command for state Failure (TTOffload)

11:45 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao
===> Error in irc_presetTelescope
        err = Resmsg[0]  = PresetTelescope result status: Error
        err = Resmsg[1]  = Stop[517] complete
        err = Resmsg[2]  = couldn't find a star in image
===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  = right Preset inactive
  • we need to home the stages at the GCS

11:48 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao - success

11:50 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao - success

11:53 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao
  • time out of the fast
===> Error in irc_presetTelescope
        err = Resmsg[0]  = PresetTelescope result status: Error
        err = Resmsg[1]  = Timeout waiting for slopecompctrl.R.FASTLINK.ENABLE.CUR (-5001) TIMEOUT_ERROR
        err = Resmsg[2]  = Stop[527] failed - Timeout waiting for slopecompctrl.R.FASTLINK.ENABLE.CUR (-5001) TIMEOUT_ERROR
===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  = right Preset inactive

11:56 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao - success

11:58 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao - success

12:01 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao
 
===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  = adsecarb:Illegal command for state Failure (TTOffload)
        err = Resmsg[2]  = AcquireRef[538] failed - adsecarb:Illegal command for state Failure (TTOffload)

12:08 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao - success

12:11 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao
 
  ===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  = adsecarb:Illegal command for state Failure (TTOffload)
        err = Resmsg[2]  = AcquireRef[545] failed - adsecarb:Illegal command for state Failure (TTOffload)

12:16 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao
 
===> Error in irc_presetTelescope
        err = Resmsg[0]  = PresetTelescope result status: Error
        err = Resmsg[1]  = Stop[546] complete
        err = Resmsg[2]  = couldn't find a star in image
===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  = right Preset inactive

12:22 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao - success

12:15 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao - success

12:28 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao
===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  = RETRY: No stars found in TV frame (-20001) WFSARB_STAR_NOTFOUND
        err = Resmsg[2]  = AcquireRef[560] failed - RETRY: No stars found in TV frame (-20001) WFSARB_STAR_NOTFOUND

12:31 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao
  • trying with mag 13
===> Error in irc_presetTelescope
        err = Resmsg[0]  = PresetTelescope result status: Error
        err = Resmsg[1]  = Stop[561] complete
        err = Resmsg[2]  = Framerate 12 is out of range for binning 4x4 (-5002) VALUE_OUT_OF_RANGE_ERROR
        err = Resmsg[3]  = PresetAO[562] failed - Framerate 12 is out of range for binning 4x4 (-5002) VALUE_OUT_OF_RANGE_ERROR
% Compiled module: IRC_RUNAO.
===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  = right Preset inactive

12:34 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao
===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  = IDL File error
        err = Resmsg[2]  = AcquireRef[565] failed - IDL File error

12:38 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao
  • trying with mag 14
===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  = IDL File error
        err = Resmsg[2]  = AcquireRef[568] failed - IDL File error

12:44 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao
 
===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  = Camera lens centering did not converge after 180 seconds
        err = Resmsg[2]  = AcquireRef[571] failed - Camera lens centering did not converge after 180 seconds

12:50 irc_runao - success
  • the first time it failed becase the star was too faint

12:52 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao - success

12:57 iif_preset,test,MODE=ACE,GS=1,RS=0,PA=0 & irc_runao
  • the lamp was turned off
===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  = RETRY: No stars found in TV frame (-20001) WFSARB_STAR_NOTFOUND
        err = Resmsg[2]  = AcquireRef[580] failed - RETRY: No stars found in TV frame (-20001) WFSARB_STAR_NOTFOUND

12:59 irc_runao - success

13:03 End of night

-- KonstantinaBoutsia - 19 Jun 2011
Topic revision: r3 - 19 Jun 2011, KonstantinaBoutsia
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.