AO Commissioning on 17 June 2011

Observer(s): G. Brusa, E. Pinna, J. Brynnel, F. Quiros-Pacheo, J. Argomedo, K. Boutsia (LBTO)

Telescope Operator: D. Gonzalez (LBTO)

SW Support: N. Cushing, D. Cox (Tucson)

Telescope Support: J. Urban (LBTO)

Instrument Support: D. Officer (LBTO)

Summary

DOME CLOSED FOR HIGH WINDS PART OF THE NIGHT.

Details

02:18 - High winds - We start testing with dome closed

AO software debugging - see Arcetri Twiki page for details

09:09 iif_preset,test, MODE=ACE,GS=1,RS=0,PA=0
  • failed because the primary mirror is down

09:16 iif_preset,test, MODE=ACE,GS=1,RS=0,PA=0

09:18 irc_runao
 
% Compiled module: IRC_RUNAO.
===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  =          err = Resmsg[2]  = AcquireRef[120] failed

09:20 irc_runao
 
===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  = No focal station selected
        err = Resmsg[2]  = AcquireRef[121] failed - No focal station selected

09:24 irc_runao
===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  =          err = Resmsg[2]  = AcquireRef[122] failed

The situation seems very similar to what we were seeing yesterday...

Now they will close the loop first and then we will send a runao - they close the loop, they do offload, they open the loop and then we send runao

we stop the guiding manually

09:37 iif_preset,test, MODE=ACE,GS=1,RS=0,PA=0
  • the preset gave no error but there is no star at the AO side... why??? - the hexapod did not move...

09:42 irc_runao
 
===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  = adsecarb:Illegal command for state Ready (SetRecMat)
        err = Resmsg[2]  = AcquireRef[125] failed - adsecarb:Illegal command for state Ready (SetRecMat)

10:05 iif_preset, test, MODE=ACE, GS=1, RS=0,PA=0

10:06 irc_runao
 
===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  =          err = Resmsg[2]  = AcquireRef[130] failed

10:20 iif_preset, test, MODE=ACE, GS=1, RS=0,PA=0

10:25 irc_runao - success!

10:27 iif_preset, test, MODE=ACE, GS=1, RS=0,PA=0 - shell rip
  • here it was not due to the antidrift

10:50 iif_preset, test, MODE=ACE, GS=1, RS=0,PA=0

10:50 irc_runao - success!

10:58 iif_preset, test, MODE=ACE, GS=1, RS=0,PA=0
  • the primary was not set
 
===> Error in irc_presetTelescope
        err = Resmsg[0]  = PresetTelescope result status: Error
        err = Resmsg[1]  = Stop[143] complete
        err = Resmsg[2]  = right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

11:07 iif_preset, test, MODE=ACE, GS=1, RS=0,PA=0
  • error from the telescope - the guide star is in the edge - retry
===> Error in irc_presetTelescope
        err = Resmsg[0]  = PresetTelescope result status: Error
        err = Resmsg[1]  = Stop[146] complete
        err = Resmsg[2]  = couldn't find a star in image

11:08 iif_preset, test, MODE=ACE, GS=1, RS=0,PA=0

11:10 irc_runao
  • failed at the beginning when it was doing the 10 mode fitting
 
===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  =          err = Resmsg[2]  = AcquireRef[150] failed

11:24 iif_preset, test, MODE=ACE, GS=1, RS=0,PA=0

11:25 irc_runao -success

11:36 iif_preset, test, MODE=ACE, GS=1, RS=0,PA=0

11:39 irc_runao - success

11:43 iif_preset, test, MODE=ACE, GS=1, RS=0,PA=0

11:44 irc_runao - success

11:46 iif_preset, test, MODE=ACE, GS=1, RS=0,PA=0

11:47 irc_runao -success

11:50 iif_preset, test, MODE=ACE, GS=1, RS=0,PA=0
  • primary is down

11:58 iif_preset, test, MODE=ACE, GS=1, RS=0,PA=0

11:59 irc_runao - success

12:03 iif_preset, test, MODE=ACE, GS=1, RS=0,PA=0

12:05 irc_runo
 
===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  =          err = Resmsg[2]  = AcquireRef[178] failed

12:15 iif_preset, test, MODE=ACE, GS=1, RS=0,PA=0

12:16 irc_runao - success
  • without the antidrift

12:20 iif_preset, test, MODE=ACE, GS=1, RS=0,PA=0
  • no star in the image - TCS error
 
===> Error in irc_presetTelescope
        err = Resmsg[0]  = PresetTelescope result status: Error
        err = Resmsg[1]  = Stop[183] complete
        err = Resmsg[2]  = couldn't find a star in image

12:20 iif_preset, test, MODE=ACE, GS=1, RS=0,PA=0
 
===> Error in irc_presetTelescope
        err = Resmsg[0]  = PresetTelescope result status: Error
        err = Resmsg[1]  = PresetAO rejected. Busy serving PresetAO [184]

12:21 iif_preset, test, MODE=ACE, GS=1, RS=0,PA=0

12:22 irc_runao - success

12:25 iif_preset, test, MODE=ACE, GS=1, RS=0,PA=0

12:26 irc_runao

12:28 iif_preset, test, MODE=ACE, GS=1, RS=0,PA=0

12:29 irc_runao - success

12:31 iif_preset, test, MODE=ACE, GS=1, RS=0,PA=0 - RIP

12:41 iif_preset, test, MODE=ACE, GS=1, RS=0,PA=0

12:44 irc_runao - success

12:45 iif_preset, test, MODE=ACE, GS=1, RS=0,PA=0

12:46 irc_runao - sucess

12:50 iif_preset, test, MODE=ACE, GS=1, RS=0,PA=0

12:51 irc_runao - sucess

12:56 iif_preset, test, MODE=ACE, GS=1, RS=0,PA=0
  • M1 failure

13:05 iif_preset, test, MODE=ACE, GS=1, RS=0,PA=0
  • failed - blocked BCU
  • err = Resmsg[2] = Reading shared buffer masterdiagnostic.R:OPTLOOPBUF (-5001) TIMEOUT_ERROR
  • err = Resmsg[3] = PresetAO[216] failed - Reading shared buffer masterdiagnostic.R:OPTLOOPBUF (-5001) TIMEOUT_ERROR

13:07 irc_runao
  • ripped in closed loop
  
===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  =          err = Resmsg[2]  = AcquireRef[219] failed

13:16 iif_preset, test, MODE=ACE, GS=1, RS=0,PA=0
  • it was sent while the loop was open

13:18 irc_runao - failed

13:24 iif_preset, test, MODE=ACE, GS=1, RS=0,PA=0
  • the preset failed because the shell was not ready

13:27 iif_preset, test, MODE=ACE, GS=1, RS=0,PA=0

13:28 irc_runao - rip

13:32 iif_preset, test, MODE=ACE, GS=1, RS=0,PA=0

13:34 irc_runao - rip

-- KonstantinaBoutsia - 17 Jun 2011
Topic revision: r4 - 19 Jun 2011, KonstantinaBoutsia
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback