Tuesday, March 2nd, 2009: Doug's Work Log

  • Caught a ride to Arcetri with Runa. Arrive at 8:30 to start installing DM on Hexapod
  • Last evening Marco found problem with testing extreme positions of Hexapod
  • Marco worked on hexapod test software till mid-afternoon
  • I had time to debug OSS software. Found logic problem (see below) and sent it and several questions and suggestions to Paul
    • /home/dlmiller/tcs/b20/oss/SecondaryMirror.cpp
          void SecondaryMirror::calcStateStatusPriority()
          ...
            else if ( isHomed()!= true )
              {
               nStatus = enumStatusOk;

              // Added DLM 3mar09
              if ( isBrakeOpen() == true )
                {
          	nState = enumStateMoving;
                }
              else
                {
          	nState = enumStateStandby;
                }
               // End Add by DLM

              nPriority = TCS::enumNotice;
          	}
            else
          ...

-- DougMiller - 03 Mar 2009