SA92_SF2

Field
finding chart
RA (2000.) Decl (2000.) B-V
range
number
of stars
TCSTGT Comments
SA92 249 00:54:43 +00:40:15 0.52 - 1.13 4 A_SA92_249  
SA92 SF2 00 56 06 +00 51 50 0.57 - 1.19 3 A_SA92_SF2  
Feige 11 01 04 25 +04 12 31 -0.24 - 0.84 3 A_F11  
PG0231+051 02:33:38 +05:18:40 -0.32 - 1.44 6 A_PG0231+051  
Feige 24 02 35 17 +03 43 00 -0.20 - 1.13 4 A_F24  
SA95_SF4 03 54 38 +00 27 20 1.23 - 1.99 3 A_SA95_SF4  
GD 71 05 52 24 +15 53 30 -0.25 - 1.18 6 A_GD71  
SA98_670 06 52 12 -00 20 56 0.00 - 1.91 11 A_SA98_670  
RU_149 07 24 16 -00 32 38 -0.13 - 1.12 8 A_RU_149  
RU_152 07 29 56 -02 05 39 -0.19 - 0.88 7 A_RU_152  
PG0918+029 09 21 34 +02 46 39 -0.27 - 1.04 5 A_PG0918+029  
PG0942-029 09 45 12 -03 08 10 -0.30 - 0.89 5 A_PG0942-029  
SA101_326 09 56 14 -00 28 00 0.58 - 1.16 3 A_SA101_326  
GD 108 10 00 48 -07 32 41 -0.21 - 0.84 5 A_GD108  
PG1047+003 10 50 09 -00 01 08 -0.29 - 0.69 4 A_PG1047+003  
SA104_334 12 42 20 -00 40 28 0.52 - 0.83 4 A_SA104_334  
PG1323-086 13 25 44 -08 50 00 -0.14 - 0.76 4 A_PG1323-086  
PG1525-071 15 28 13 -07 16 01 -0.21 - 1.12 5 A_PG1525-071  
SA107_602 15 39 14 -00 14 55 0.50 - 1.41 4 A_SA107_602  
PG1633+099 16 35 34 +09 47 08 -0.19 - 1.14 7 A_PG1633+099  
SA110_229 18 40 49 +00 01 37 0.73 - 1.91 4 A_SA110_229  
Mark A 20 43 59 -10 46 37 -0.25 - 0.94 5 A_MarkA  
G26-7 21 31 17 -09 49 00 0.56 - 1.66 4 A_G26-7  
G93-48 21 52 17 +02 22 30 -0.01 - 1.32 5 A_G93-48  
PG2213-006 22 16 24 -00 21 27 -0.21 - 0.75 4 A_PG2213-006  
GD246 23 12 25 +10 47 30 -0.32 - 0.92 4 A_GD246  
PG2336+004 23 38 41 +00 42 59 -0.16 - 0.69 3 A_PG2336+004  

Object visibility

Today object visibility for the Landlot photometric standards observed from Mt Graham Observatory.


The visibility plot of today:


Minimum observing altitude: 25 degrees.

Please wait ... Genrating visibility plot

 

Groups

SA92-249

Star V B-V U-B V-R V-I n m
SA 92 249 14.325±.0049 +0.699±.0085 +0.240±.0114 +0.399±.0049 +0.770±.0073 17 8
SA 92 250 13.178±.0022 +0.814±.0034 +0.480±.0074 +0.446±.0022 +00.84±.0029 20 9
SA 92 252 14.932±.0033 +0.517±.0055 -0.140±.0082 +0.326±.0033 +0.666±.0068 41 18
SA 92 253 14.085±.0032 +1.131±.0062 +0.955±.0221 +0.719±.0032 +1.337±.0050 39 17

n: number of times star was observed
m: number of nights star was observed

The circle around a star indicates the U-B-colour.

92_249.png

SA92-SF2

Star V B-V U-B V-R V-I n m
SA92 425 13.941±.0025 +1.191±.0067 +1.173±.0115 +0.755±.0038 +1.384±.0038 36 19
SA92 426 14.466±.0099 +0.729±.0131 +0.184±.0293 +0.412±.0099 +0.809±.0120 8 4
SA92 355 14.965±.0088 +1.164±.0124 +1.201±.0465 +0.759±.0088 +1.406±.0090 15 7
SA92 430 14.440±.0041 +0.567±.0052 -0.040±.0081 +0.338±.0041 +0.767±.0051 35 18
n: number of times star was observed
m: number of nights star was observed

The circle around a star indicates the U-B-colour.

92_sf2.png

F11

Star V B-V U-B V-R V-I n m
F 11 12.065±.0007 -0.239±.0007 -0.988±.0017 -0.118±.0006 -0.142±.0010 91 75
F 11A 14.475±.0027 +0.841±.0046 +0.454±.0128 +0.479±.0036 +0.426±.0075 16 7
F 11B 13.784±.0025 +0.747±.0026 +0.234±.0043 +0.437±.0021 +0.412±.0036 14 7
n: number of times star was observed
m: number of nights star was observed

The circle around a star indicates the U-B-colour.

PG0231

Star V B-V U-B V-R V-I n m
PG0231+051 16.096±.0055 -0.320±.0057 -1.214±.0028 -0.144±.0055 -0.502±.0654 33 18
PG0231+051A 12.768±.0004 +0.711±.0011 +0.271±.0007 +0.405±.0004 +0.794±.0017 16 10
PG0231+051B 14.732±.0017 +1.437±.0049 +1.279±.0119 +0.951±.0017 +1.933±.0022 26 14
PG0231+051C 13.707±.0009 +0.678±.0019 +0.078±.0011 +0.396±.0009 +0.783±.0019 16 9
PG0231+051D 14.031±.0018 +1.077±.0022 +1.026±.0081 +0.671±.0018 +1.252±.0034 19 11
PG0231+051E 13.809±.0019 +0.677±.0014 +0.207±.0019 +0.383±.0019 +0.752±.0019 15 8

SA92

Star V B-V U-B V-R V-I n m
SA 92 249 14.325±.0049 +0.699±.0085 +0.240±.0114 +0.399±.0049 +0.770±.0073 17 8
SA 92 250 13.178±.0022 +0.814±.0034 +0.480±.0074 +0.446±.0022 +00.84±.0029 20 9
SA 92 252 14.932±.0033 +0.517±.0055 -0.140±.0082 +0.326±.0033 +0.666±.0068 41 18
SA 92 253 14.085±.0032 +1.131±.0062 +0.955±.0221 +0.719±.0032 +1.337±.0050 39 17

Star V B-V U-B V-R V-I n m
SA92 425 13.941±.0025 +1.191±.0067 +1.173±.0115 +0.755±.0038 +1.384±.0038 36 19
SA92 426 14.466±.0099 +0.729±.0131 +0.184±.0293 +0.412±.0099 +0.809±.0120 8 4
SA92 355 14.965±.0088 +1.164±.0124 +1.201±.0465 +0.759±.0088 +1.406±.0090 15 7
SA92 430 14.440±.0041 +0.567±.0052 -0.040±.0081 +0.338±.0041 +0.767±.0051 35 18

Star V B-V U-B V-R V-I n m
F 11 12.065±.0007 -0.239±.0007 -0.988±.0017 -0.118±.0006 -0.142±.0010 91 75
F 11A 14.475±.0027 +0.841±.0046 +0.454±.0128 +0.479±.0036 +0.426±.0075 16 7
F 11B 13.784±.0025 +0.747±.0026 +0.234±.0043 +0.437±.0021 +0.412±.0036 14 7
n: number of times star was observed
m: number of nights star was observed

The circle around a star indicates the U-B-colour.

f11.png

Star V B-V U-B V-R V-I n m
F 24 12.412±.0010 -0.203±.0006 -1.182±.0017 +0.087±.0008 +0.361±.0010 128 115
F 24A 13.822±.0016 +0.525±.0025 +0.034±.0036 +0.314±.0016 +0.319±.0026 20 10
F 24B 13.546±.0018 +0.668±.0020 +0.188±.0035 +0.382±.0015 +0.367±.0021 19 10
F 24C 11.761±.0015 +1.133±.0012 +1.007±.0036 +0.598±.0005 +0.535±.0011 18 9
n: number of times star was observed

m: number of nights star was observed

The circle around a star indicates the U-B-colour.

Star V B-V U-B V-R V-I n m
SA 95 330 12.174±.0025 +1.999±.0026 +2.233±.0137 +1.166±.0025 +2.268±.0028 47 23
SA 95 275 13.479±.0028 +1.763±.0054 +1.740±.0201 +1.011±.0028 +1.944±.0025 40 20
SA 95 276 14.118±.0061 +1.225±.0102 +1.218±.0216 +0.748±.0061 +1.395±.0051 14 7
n: number of times star was observed
m: number of nights star was observed

The circle around a star indicates the U-B-colour.

GD_71

Mount Lemon Optical Astronomy Observatory (Arizona, USA)

Star V B-V U-B V-R V-I n m
GD 71 13.033±.0011 -0.248±.0009 -1.110±.0010 -0.138±.0009 -0.304±.0021 129 115
GD 71A 12.643±.0013 +1.176±.0021 +0.897±.0051 +0.651±.0009 +1.265±.0016 24 12
GD 71B 12.599±.0018 +0.680±.0020 +0.166±.0026 +0.404±.0015 +0.800±.0015 19 11
GD 71C 12.325±.0017 +1.159±.0022 +0.849±.0057 +0.655±.0012 +1.274±.0017 19 11
GD 71D 12.898±.0018 +0.570±.0020 +0.097±.0038 +0.359±.0017 +0.719±.0024 19 11
GD 71E 13.634±.0013 +0.824±.0027 +0.428±.0082 +0.472±.0012 +0.892±.0037 14 7
n: number of times star was observed

m: number of nights star was observed

The circle around a star indicates the U-B-colour.

gd71.png

Star V B-V U-B V-R V-I n m
98 650 12.271±.0020 +0.157±.0014 +0.110±.0041 +0.080±.0020 +0.166±.0027 31 20
98 653 9.5381±.0007 -0.003±.0003 -0.102±.0008 +0.010±.0010 +0.017±.0007 114 98
98 666 12.732±.0034 +0.164±.0028 -0.004±.0042 +0.091±.0034 +0.200±.0048 25 14
98 670 11.930±.0005 +1.357±.0009 +1.325±.0036 +0.727±.0005 +1.381±.0007 80 66
98 671 13.385±.0037 +0.968±.0048 +0.719±.0108 +0.575±.0071 +1.071±.0046 27 15
98 675 13.398±.0026 +1.909±.0035 +1.936±.0283 +1.082±.0026 +2.085±.0024 44 21
98 676 13.068±.0032 +1.146±.0041 +0.666±.0107 +0.683±.0032 +1.352±.0032 17 8
98 L5 17.800±.1633 +1.900±.3266 -0.100±.4491 +3.100±.1644 +5.800±.1225 6 3
98 682 13.749±.0039 +0.632±.0039 +0.098±.0064 +0.366±.0039 +0.717±.0039 13 7
98 685 11.954±.0030 +0.463±.0021 +0.096±.0028 +0.290±.0030 +0.570±.0034 22 14
98 688 12.754±.0033 +0.293±.0024 +0.245±.0081 +0.158±.0033 +0.337±.0074 21 11
n: number of times star was observed
m: number of nights star was observed

Note, star L5 is extremely red

The circle around a star indicates the U-B-colour.

98_670.png

Star V B-V U-B V-R V-I n m
Ru 149 13.866±.0022 -0.129±.0027 -0.779±.0031 -0.040±.0022 -0.108±.0069 46 30
Ru 149A 14.495±.0066 +0.298±.0052 +0.118±.0111 +0.196±.0066 +0.391±.0139 18 12
Ru 149B 12.642±.0021 +0.662±.0034 +0.151±.0049 +0.374±.0021 +0.728±.0028 15 10
Ru 149C 14.425±.0052 +0.195±.0042 +0.141±.0111 +0.093±.0052 +0.222±.0106 18 11
Ru 149D 11.480±.0019 -0.037±.0021 -0.287±.0028 +0.021±.0019 +0.029±.0024 18 11
Ru 149E 13.718±.0064 +0.522±.0049 -0.007±.0069 +0.321±.0064 +0.637±.0087 12 8
Ru 149F 13.471±.0028 +1.115±.0078 +1.025±.0223 +0.594±.0028 +1.132±.0034 19 11
Ru 149G 12.829±.0026 +0.541±.0040 +0.033±.0042 +0.322±.0026 +0.645±.0040 18 12
n: number of times star was observed
m: number of nights star was observed

The circle around a star indicates the U-B-colour.

ru149.png

Star V B-V U-B V-R V-I n m
Ru 152F 14.564±.0052 +0.635±.0057 +0.069±.0096 +0.382±.0052 +0.689±.0222 15 8
Ru 152E 13.362±.0042 +0.042±.0020 -0.086±.0020 +0.030±.0014 +0.065±.0029 12 8
Ru 152 13.017±.0011 -0.187±.0017 -1.081±.0023 -0.059±.0011 -0.147±.0027 48 33
Ru 152B 15.019±.0046 +0.500±.0088 +0.022±.0181 +0.290±.0046 +0.600±.0211 23 10
Ru 152A 14.341±.0061 +0.543±.0086 -0.085±.0168 +0.325±.0061 +0.654±.0131 14 8
Ru 152C 12.222±.0025 +0.573±.0031 -0.013±.0033 +0.342±.0025 +0.683±.0031 12 8
Ru 152D 11.076±.0013 +0.875±.0016 +0.491±.0024 +0.473±.0013 +0.921±.0019 14 10
n: number of times star was observed
m: number of nights star was observed

The circle around a star indicates the U-B-colour.

ru152.png

Star V B-V U-B V-R V-I n m
PG0918+029 13.327±.0024 -0.271±.0024 -1.081±.0030 -0.129±.0024 -0.288±.0063 45 27
PG0918+029A 14.490±.0033 +0.536±.0058 -0.032±.0095 +0.325±.0033 +0.661±.0085 29 14
PG0918+029B 13.963±.0034 +0.765±.0072 +0.366±.0159 +0.417±.0034 +0.787±.0056 20 11
PG0918+029C 13.537±.0020 +0.631±.0028 +0.087±.0049 +0.367±.0020 +0.722±.0028 21 10
PG0918+029D 12.272±.0021 +1.044±.0030 +0.821±.0071 +0.575±.0021 +1.108±.0018 19 11
n: number of times star was observed
m: number of nights star was observed

The circle around a star indicates the U-B-colour.

Star V B-V U-B V-R V-I n m
PG0942-029D 13.683±.0009 +0.576±.0029 +0.064±.0054 +0.341±.0009 +0.668±.0044 13 8
PG0942-029A 14.738±.0021 +0.888±.0021 +05522±.0065 +0.563±.0021 +1.035±.0050 16 8
PG0942-029B 14.105±.0022 +0.573±.0014 +0.014±.0043 +0.353±.0022 +0.693±.0041 13 8
PG0942-029 14.012±.0022 -0.298±.0025 -1.177±.0031 -0.132±.0022 -0.296±.0067 21 13
PG0942-029C 14.950±.0024 +0.803±.0024 +0.338±.0049 +0.488±.0024 +0.884±.0053 16 8
n: number of times star was observed

m: number of nights star was observed

The circle around a star indicates the U-B-colour.

Star V B-V U-B V-R V-I n m
SA 101 326 14.923±.0078 +0.729±.0094 +0.227±.0128 +0.406±.0078 +0.780±.0122 13 6
SA 101 327 13.441±.0032 +1.155±.0057 +1.139±.0098 +0.717±.0032 +1.290±.0028 28 15
SA 101 330 13.723±.0038 +0.577±.0038 -0.026±.0051 +0.346±.0038 +0.684±.0064 28 14
n: number of times star was observed
m: number of nights star was observed

The circle around a star indicates the U-B-colour.

Note the standard star SA 101 262, near x=1500, y=400, was observed four times in two nights by Landolt.

sa101_326.png

GD108

Star V B-V U-B V-R V-I n m
GD108 13.563 ±.0025 -0.214 ±.0038 -0.943 ±.0039 -0.099 ±.0025 -0.218 ±.0026 22 13
GD 108A 13.881±.0018 +0.789±.0032 +0.316±.0066 +0.458±.0018 +0.909±.0011 15 8
GD 108B 15.056±.0019 +0.839±.0043 +0.364±.0092 +0.463±.0019 +0.924±.0048 20 9
GD 108C 13.819±.0011 +0.786±.0034 +0.345±.0037 +0.435±.0011 +0.825±.0043 16 9
GD 108D 14.235±.0010 +0.641±.0020 +0.078±.0050 +0.372±.0010 +0.731±.0034 16 8
n: number of times star was observed

m: number of nights star was observed

The circle around a star indicates the U-B-colour.

Star V B-V U-B V-R V-I n m
PG1047+003 13.474±.0039 -0.290±.0030 -1.121±.0041 -0.132±.0037 -0.295±.0110 32 18
PG1047+003A 13.512±.0046 +0.688±.0049 +0.168±.0067 +0.422±.0026 +0.840±.0036 15 7
PG1047+003B 14.751±.0050 +0.679±.0086 +0.172±.0128 +0.391±.0022 +0.764±.0086 13 5
PG1047+003C 12.453±.0093 +0.607±.0024 -0.019±.0060 +0.378±.0036 +0.737±.0045 11 6
n: number of times star was observed

m: number of nights star was observed

The circle around a star indicates the U-B-colour.

Star V B-V U-B V-R V-I n m
SA 104 330 15.296±.0103 +0.594±.0276 -0.028±.0155 +0.369±.0103 +0.739±.0225 15 6
SA 104 334 13.484±.0047 +0.518±.0031 -0.067±.0039 +0.323±.0047 +0.653±.0047 24 16
SA 104 336 14.404±.0067 +0.830±.0072 +0.495±.0123 +0.461±.0067 +0.865±.0104 14 6
SA 104 338 16.059±.0078 +0.591±.0219 -0.082±.0368 +0.348±.0078 +0.719±.0170 8 5
n: number of times star was observed
m: number of nights star was observed

The circle around a star indicates the U-B-colour.

Star V B-V U-B V-R V-I n m Comment
PG1323-086 13.481±.0019 -0.140±.0022 -0.681±.0026 -0.048±.0019 -0.127±.0045 39 18  
PG1323-086A 13.591±.0257 +0.393±.0022 -0.019±.0045 +0.252±.0257 +0.506±.0060 20 12 Variable?
PG1323-086B 13.406±.0019 +0.761±.0029 +0.265±.0042 +0.426±.0019 +0.833±.0031 23 13  
PG1323-086C 14.003±.0031 +0.707±.0027 +0.245±.0076 +0.395±.0031 +0.759±.0049 26 13  
n: number of times star was observed
m: number of nights star was observed

The circle around a star indicates the U-B-colour.

Star V B-V U-B V-R V-I n m Comment
PG1525-071 15.046±.0027 -0.211±.0005 -1.177±.0027 -0.068±.0020 +0.012±.0020 20 13  
PG1525-071A 13.506±.0008 +0.773±.0015 +0.282±.0019 +0.437±.0006 +0.421±.0024 15 8  
PG1525-071B 16.392±.0039 +0.729±.0043 +0.141±.0097 +0.450±.0037 +0.387±.0066 17 8  
PG1525-071C 13.519±.0007 +1.116±.0028 +1.073±.0052 +0.593±.0010 +0.509±.0015 16 9  
PG1525-071D 16.300±.0021 +0.393±.0714 +0.224±.0316 +0.405±.0108 +0.343±.0196 15 8 Variable?
n: number of times star was observed
m: number of nights star was observed

The circle around a star indicates the U-B-colour.

Star V B-V U-B V-R V-I n m
SA 107 599 14.675±.0082 +0.698±.0121 +0.243±.0061 +0.433±.0082 +0.869±.0155 17 7
SA 107 600 14.884±.0170 +0.503±.0130 +0.049±.0227 +0.339±.0170 +0.700±.0203 9 4
SA 107 601 14.646±.0045 +1.412±.0073 +1.265±.0247 +0.923±.0045 +1.761±.0038 33 13
SA 107 602 12.116±.0027 +0.991±.0029 +0.585±.0070 +0.545±.0027 +1.074±.0032 17 9
n: number of times star was observed
m: number of nights star was observed

The circle around a star indicates the U-B-colour.

Star V B-V U-B V-R V-I n m
PG1633+099 14.396±.0016 -0.191±.0021 -0.990±.0031 -0.085±.0016 -0.208±.0107 20 11
PG1633+099A 15.259±.0032 +0.871±.0042 +0.305±.0037 +0.506±.0032 +1.011±.0099 23 10
PG1633+099B 12.968±.0016 +1.081±.0013 +1.017±.0051 +0.589±.0016 +1.090±.0019 18 11
PG1633+099C 13.224±.0017 +1.144±.0008 +1.146±.0022 +0.612±.0017 +1.133±.0027 17 10
PG1633+099D 13.689±.0016 +0.535±.0018 -0.021±.0028 +0.324±.0016 +0.649±.0020 20 12
PG1633+099E 13.113±.0021 +0.841±.0020 +0.337±.0037 +0.484±.0021 +0.953±.0024 16 9
PG1633+099F 13.768±.0020 +0.878±.0024 +0.254±.0048 +0.523±.0020 +1.035±.0028 15 8
n: number of times star was observed
m: number of nights star was observed

The circle around a star indicates the U-B-colour.

pg1633.png

Star V B-V U-B V-R V-I n m
SA 110 299 13.649±.0031 +1.910±.0091 +1.391±.0225 +1.198±.0031 +2.356±.0026 30 16
SA 110 230 14.281±.0031 +1.084±.0050 +0.728±.0116 +0.624±.0031 +1.218±.0050 21 11
SA 110 232 12.516±.0032 +0.729±.0028 +0.147±.0045 +0.439±.0032 +0.889±.0025 28 16
SA 110 233 12.771±.0028 +1.281±.0034 +0.812±.0070 +0.773±.0028 +1.593±.0021 22 11
n: number of times star was observed
m: number of nights star was observed

The circle around a star indicates the U-B-colour.

Star V B-V U-B V-R V-I n m
Mark A 13.256±.0008 -0.246±.0008 -1.159±.0021 -0.114±.0008 -0.238±.0029 88 71
Mark A1 15.911±.0040 +0.609±.0090 -0.014±.0136 +0.367±.0040 +0.740±.0148 25 10
Mark A2 14.540±.0028 +0.666±.0031 +0.096±.0046 +0.379±.0028 +0.751±.0059 21 10
Mark A3 14.818±.0023 +0.938±.0034 +0.651±.0104 +0.587±.0023 +1.098±.0045 22 10
Mark A4 14.767±.0020 +0.795±.0030 +0.176±.0040 +0.471±.0020 +0.952±.0052 22 11
n: number of times star was observed
m: number of nights star was observed

The circle around a star indicates the U-B-colour.

Star V B-V U-B V-R V-I n m
G26-7A 13.047±.0016 +0.725±.0017 +0.279±.0025 +0.405±.0016 +0.776±.0022 17 9
G26-7 12.006±.0017 +1.664±.0006 +1.231±.0041 +1.298±.0017 +2.968±.0015 25 12
G26-7C 12.468±.0006 +0.624±.0013 +0.093±.0042 +0.354±.0006 +0.695±.0010 12 6
G26-7B 13.454±.0017 +0.562±.0021 +0.027±.0037 +0.323±.0017 +0.652±.0029 16 9
n: number of times star was observed

m: number of nights star was observed

The circle around a star indicates the U-B-colour.

Star V B-V U-B V-R V-I n m
G93-48D 13.664±.0016 +0.636±.0025 +0.120±.0033 +0.368±.0016 +0.724±.0030 21 9
G93-48C 12.664±.0005 +1.320±.0015 +1.260±.0054 +0.852±.0005 +1.610±.0018 33 16
G93-48A 12.856±.0017 +0.715±.0020 +0.278±.0032 +0.403±.0017 +0.772±.0023 26 14
G94 48B 12.416±.0019 +0.719±.0017 +0.194±.0038 +0.405±.0019 +0.791±.0020 25 14
G93-48 12.743±.0006 -0.011±.0007 -0.790±.0016 -0.096±.0006 -0.195±.0018 106 90
n: number of times star was observed
m: number of nights star was observed

The circle around a star indicates the U-B-colour.

Star V B-V U-B V-R V-I n m
PG2213-006 14.137±.0010 -0.214±.0014 -1.176±.0006 -0.072±.0010 -0.211±.0057 33 18
PG2213-006A 14.180±.0006 +0.665±.0007 +0.094±.0025 +0.407±.0006 +0.817±.0030 32 17
PG2213-006B 12.710±.0007 +0.753±.0014 +0.291±.0018 +0.427±.0007 +0.831±.0012 24 13
PG2213-006C 15.108±.0020 +0.726±.0030 +0.175±.0039 +0.425±.0020 +0.853±.0047 34 17
n: number of times star was observed

m: number of nights star was observed

The circle around a star indicates the U-B-colour.

Star V B-V U-B V-R V-I n m
GD246 13.090±.0009 -0.318±.0009 -1.194±.0014 -0.148±.0008 -0.328±.0021 113 97
GD246A 12.962±.0019 +0.463±.0022 -0.047±.0034 +0.288±.0017 +0.584±.0025 21 11
GD246B 14.368±.0019 +0.919±.0028 +0.693±.0111 +0.512±.0023 +0.944±.0070 20 09
GD246C 13.637±.0018 +0.879±.0015 +0.540±.0052 +0.484±.0016 +0.933±.0031 20 10
n: number of times star was observed
m: number of nights star was observed

The circle around a star indicates the U-B-colour.

Star V B-V U-B V-R V-I n m
PG2336+004 15.885±.0070 -0.160±.0056 -0.781±.0007 -0.056±.0079 -0.048±.0125 10 5
PG2336+004A 11.274±.0006 +0.686±.0006 +0.129±.0011 +0.394±.0007 +0.382±.0006 10 5
PG2336+004B 12.429±.0006 +0.517±.0008 -0.048±.0012 +0.313±.0003 +0.317±.0012 10 5
n: number of times star was observed
m: number of nights star was observed

The circle around a star indicates the U-B-colour.

-- JuanGuerra - 19 Mar 2013
  • 92_249:
    92_249.png

  • 92_sf2:
    92_sf2.png

  • 95_sf4:
    95_sf4.png

  • 98_670:
    98_670.png

  • 104_334:
    104_334.png

  • 107_602:
    107_602.png

  • 110_229:
    110_229.png

  • f11:
    f11.png

  • g26_7:
    g26-7.png

  • g93_48:
    g93-48.png

  • gd71:
    gd71.png

  • gd108:
    gd108.png

  • gd246:
    gd246.png

  • marka:
    marka.png

  • pg0231:
    pg0231.png

  • pg0981:
    pg0918.png

  • pg0942:
    pg0942.png

  • pg1047:
    pg1047.png

  • pg1323:
    pg1323.png

  • pg1525:
    pg1525.png

  • pg1633:
    pg1633.png

  • pg2213:
    pg2213.png

  • pg2336:
    pg2336.png

  • ru149:
    ru149.png

  • ru152:
    ru152.png

  • sa101_326:
    sa101_326.png
I Attachment Action Size Date Who Comment
104_334.pngpng 104_334.png manage 294 K 19 Mar 2013 - 18:49 UnknownUser 104_334
107_602.pngpng 107_602.png manage 301 K 19 Mar 2013 - 18:49 UnknownUser 107_602
110_229.pngpng 110_229.png manage 396 K 19 Mar 2013 - 18:50 UnknownUser 110_229
92_249.pngpng 92_249.png manage 262 K 19 Mar 2013 - 18:48 UnknownUser 92_249
92_sf2.pngpng 92_sf2.png manage 313 K 19 Mar 2013 - 18:48 UnknownUser 92_sf2
95_sf4.pngpng 95_sf4.png manage 284 K 19 Mar 2013 - 18:48 UnknownUser 95_sf4
98_670.pngpng 98_670.png manage 322 K 19 Mar 2013 - 18:49 UnknownUser 98_670
f11.pngpng f11.png manage 274 K 19 Mar 2013 - 18:50 UnknownUser f11
g26-7.pngpng g26-7.png manage 323 K 19 Mar 2013 - 18:51 UnknownUser g26_7
g93-48.pngpng g93-48.png manage 313 K 19 Mar 2013 - 18:51 UnknownUser g93_48
gd108.pngpng gd108.png manage 284 K 19 Mar 2013 - 18:51 UnknownUser gd108
gd246.pngpng gd246.png manage 283 K 19 Mar 2013 - 18:52 UnknownUser gd246
gd71.pngpng gd71.png manage 283 K 19 Mar 2013 - 18:51 UnknownUser gd71
marka.pngpng marka.png manage 301 K 19 Mar 2013 - 18:52 UnknownUser marka
pg0231.pngpng pg0231.png manage 296 K 19 Mar 2013 - 18:52 UnknownUser pg0231
pg0918.pngpng pg0918.png manage 366 K 19 Mar 2013 - 18:53 UnknownUser pg0981
pg0942.pngpng pg0942.png manage 316 K 19 Mar 2013 - 18:53 UnknownUser pg0942
pg1047.pngpng pg1047.png manage 267 K 19 Mar 2013 - 18:53 UnknownUser pg1047
pg1323.pngpng pg1323.png manage 319 K 19 Mar 2013 - 18:54 UnknownUser pg1323
pg1525.pngpng pg1525.png manage 308 K 19 Mar 2013 - 18:54 UnknownUser pg1525
pg1633.pngpng pg1633.png manage 303 K 19 Mar 2013 - 18:54 UnknownUser pg1633
pg2213.pngpng pg2213.png manage 305 K 19 Mar 2013 - 18:55 UnknownUser pg2213
pg2336.pngpng pg2336.png manage 285 K 19 Mar 2013 - 18:55 UnknownUser pg2336
ru149.pngpng ru149.png manage 306 K 19 Mar 2013 - 18:55 UnknownUser ru149
ru152.pngpng ru152.png manage 301 K 19 Mar 2013 - 18:55 UnknownUser ru152
sa101_326.pngpng sa101_326.png manage 311 K 19 Mar 2013 - 18:56 UnknownUser sa101_326
Topic revision: r5 - 22 Mar 2013, JuanGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback