The reconstructors in the system called: table_IRTC_ACE-AO.txt

mag flux bin freq phot modes base rec filtering pupils slopenull tt gain fw1_acq fw2_acq fw1_obs fw2_obs TVbin TVfreq TVavg TVflux base and REC for CL centering Freq
3.5 18700000 1 990 19000 100 KL_v10 20120604_085946 pureIntegrator 00120531-163320 zero 3 0.1 0 0 0 1 4 4.3 20 15000 KL_v10 20120602_233509 100
5.5 2970000 1 990 3000 100 KL_v10 20120604_085946 pureIntegrator 00120531-163320 zero 3 0.1 0 0 0 1 4 4.3 20 5000 KL_v10 20120602_233509 100   6.4 1287000 1 990 1300 100 KL_v10 20120604_085946 pureIntegrator 00120531-163320 zero 3 0.1 0 0 0 1 4 4.3 20 2000 KL_v10 20120602_233509 100   7.4 495000 1 990 500 100 KL_v10 20120604_085946 pureIntegrator 00120531-163320 zero 3 0.1 0 0 0 1 4 4.3 20 800 KL_v10 20120602_233509 100
8.4 210870 1 990 213 100 KL_v10 20120604_085946 pureIntegrator 00120531-163320 zero 3 0.1 0 0 0 0 4 4.3 20 300 KL_v10 20120602_233509 100
9.4 84150 1 990 85 100 KL_v10 20120604_085946 pureIntegrator 00120531-163320 zero 3 0.1 0 0 0 0 16 4.3 20 2400 KL_v10 20120602_233509 100
9.8 48400 1 990 48 100 KL_v10 20120604_085946 pureIntegrator 00120531-163320 zero 3 0.1 0 0 0 0 16 4.3 20 1500 KL_v10 20120602_233509 100
9.8 48400 2 990 192 153 KL_v9 20120204_222220 pureIntegrator 20120204-215724 zero 3 0.1 0 0 0 0 16 4.3 20 1500 KL_v9 20120204_221623 100
11.4 13336 2 990 54 153 KL_v9 20120204_222220 pureIntegrator 20120204-215724 zero 3 0.1 3 0 0 0 16 12.6 100 700 KL_v9 20120204_221623 100
11.9 8414 2 625 85 153 KL_v9 20120204_222220 pureIntegrator 20120204-215724 zero 3 0.1 3 0 0 0 16 12.6 100 7000 KL_v9 20120204_221623 100   12.4 5309 2 625 34 120 KL_v9 20120204_222220 pureIntegrator 20120204-215724 zero 3 0.1 3 0 0 0 16 12.6 100 7000 KL_v9 20120204_221623 100
13.4 2054 2 400 25 110 KL_v9 20120204_222220 pureIntegrator 20120204-215724 zero 3 0.1 3 0 0 0 16 12.6 100 2500 KL_v9 20120204_221623 100
13.4 2054 3 200 115 66 KL_v9 20120330_201828 pureIntegrator 20120330-194319 zero 6 0.1 4 0 0 0 16 12.6 100 2500 KL_v9 20120330_200149 100   14.4 818 3 200 34 66 KL_v9 20120330_201828 pureIntegrator 20120330-194319 zero 6 0.1 4 0 0 0 16 12.6 100 1700 KL_v9 20120330_200149 100
14.4 818 4 300 43 36 KL_v9 20120331_200610 pureIntegrator 20120331-182642 zero 6 0.1 4 0 0 0 16 12.6 100 1700 KL_v9 20120331_200610 100
15.4 325 4 200 27 36 KL_v9 20120331_200610 pureIntegrator 20120331-182642 zero 6 0.1 4 0 0 0 16 12.6 100 600 KL_v9 20120331_200610 100
16.4 129 4 105 21 36 KL_v9 20120331_200610 pureIntegrator 20120331-182642 zero 6 0.1 4 0 0 0 16 12.6 100 250 KL_v9 20120331_200610 100
17.5 48 4 105 8 36 KL_v9 20120331_200610 pureIntegrator 20120331-182642 zero 6 0.1 4 0 0 0 16 12.6 100 90 KL_v9 20120331_200610 100