7 June 2018 DX AdSec Jumping Actuator Results

Capacitvie Sensor Measurement While Shell Set (No closed Loop AO)

  • Notes:
    • The data displayed are all with the Shell Set
    • The Shell was Rested and Set at about 03:20 and 08:05. The data durning these Rests were removed
    • Actuator lists:
      • Bad: 70, 223, 260
      • Big Jumping or wandering: 340, 343, 367, 452, 453
      • Small Jumping or Wandering: 104, 216, 376, 555, 556
    • Real Actuator Jumps
      • Plot with Bad Actuators
      • Plot with 1.0e-7 < sigma
    • May be induced changes in position due to jumping actuators near by
      • Plots with 3.8e-8 < sigma <= 5.0e-8
      • Plots with 5.0e-8 < sigma <= 1.0e-7
        • e.g. Actuators 217 and 218 change when actuator 216 jumps.
        • I will check several of these possible induced jumps

  • Actuator Distance Standard Deviation While Shell is Set:
    dist_sigma.jpg

  • Actuators with 1.0e-7 < sigma:
    dist_cut_1e-7.jpg

* Actuators with 5.0e-8 < sigma <= 1.0e-7:
dist_cut_5e-8.jpg

  • Actuators with 3.8e-8 < sigma <= 5.0e-8:
    dist_cut_3.8e-8.jpg

  • Actuators with Bad sigmas:
    dist_cut_bad.jpg

  • Actuators with Good sigmas 1.0e-8 < sigma < 2.0e-8 (for comparison):
    dist_cut_good.jpg

  • Average Capacitive Sensor Measurements While Shell Set:
    dist_ave.jpg

-- %USERSIG{DougMiller - 2018-07-26}%
I Attachment Action Size Date Who Comment
dist_ave.jpgjpg dist_ave.jpg manage 194 K 26 Jul 2018 - 18:31 DougMiller Average Capacitive Sensor Measurements While the Shell is Set
dist_cut_1e-7.jpgjpg dist_cut_1e-7.jpg manage 264 K 26 Jul 2018 - 17:54 DougMiller Actuators with 1.0e-7 < sigma
dist_cut_3.8e-8.jpgjpg dist_cut_3.8e-8.jpg manage 256 K 26 Jul 2018 - 17:27 DougMiller actuators with 3.8e-8 < sigma <= 5.0e-8
dist_cut_5e-8.jpgjpg dist_cut_5e-8.jpg manage 266 K 26 Jul 2018 - 17:26 DougMiller Actuators with 5.0e-8 < sigma <= 1.0e-7
dist_cut_bad.jpgjpg dist_cut_bad.jpg manage 171 K 26 Jul 2018 - 18:05 DougMiller actuators with Bad sigmas
dist_cut_good.jpgjpg dist_cut_good.jpg manage 221 K 26 Jul 2018 - 18:06 DougMiller Actuators with Good sigmas 1.0e-8 < sigma < 2.0e-8
dist_sigma.jpgjpg dist_sigma.jpg manage 226 K 26 Jul 2018 - 18:07 DougMiller Actuator Distance Standard Deviation While Shell is Set
Topic revision: r2 - 26 Jul 2018, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback