4 June 2018 DX AdSec Jumping Actuator Results

Capacitvie Sensor Measurement While Shell Set (No closed Loop AO)

  • Notes:
    • The data displayed are all with the Shell Set
    • The Shell was Rested and Set at about 03:20 and 08:05. The data durning these Rests were removed
    • Actuator lists:
      • Bad: 70, 223, 260, 378, 379
      • Large distance: 340 (96 um)
      • Jumping Acts: 376, 453, 479, 555, 556