Night Log.

Wiki log.

Seeing and SR measurements.

seeing_sr-mag.png

OptimizeGain.

datetime Finished Mag file Gains Note

20230114 01:56:01 Success 16.1   g_tt_5.48_ho1_0.59_ho2_0.10 xx

20230114 02:06:41 Success 15.9   g_tt_2.81_ho1_1.80_ho2_0.10 xx

20230114 02:34:27 Success 13.8   g_tt_10.10_ho1_2.09_ho2_1.19 xx

20230114 02:46:20 Success 16.4   g_tt_3.16_ho1_1.46_ho2_0.10 xx

20230114 03:29:04 Success 17.4   g_tt_0.08_ho1_3.30_ho2_0.10 Wrong values. system set to g_tt_1.98_ho1_1.86_ho2_0.10

Events


Total: 5
|20230114 01:45:30 RIP Detected by FastDiagnostic
|20230114 01:48:27 FailedActuator Act: 569 - Failing actuator detected N. 569 Value: 0.267411 on position (CHDISTAVERAGE-0569)
|20230114 04:09:36 FailedActuator Act: 593 - Failing actuator detected N. 593 Value: 0.000430749 on position (CHDISTAVERAGE-0593)
|20230114 10:45:40 FailedActuator Act: 234 - Failing actuator detected N. 234 Value: 0.262892 on position (CHDISTAVERAGE-0234)
|20230114 13:56:54 FailedActuator Act: 280 - Failing actuator detected N. 280 Value: 0.000173198 on position (CHDISTAVERAGE-0280)

Complete observations (from PresetAO to StopAO, instrument presets only)
Total: 5 - Success rate: 100%
|20230114 01:52:09 Success FLAO, open shutter: 309s (52%)
|20230114 02:03:36 Success FLAO, open shutter: 740s (52%)
|20230114 02:27:26 Success FLAO, open shutter: 262s (32%)
|20230114 02:41:06 Success FLAO, open shutter: 2054s (78%)
|20230114 03:25:02 Success FLAO, open shutter: 2058s (79%)

PresetAO
Total: 8 - Success rate: 87%
|20230114 01:37:01 Success FLAO, star mag= 15.2, posXY= -0.1, 0.0 mm, mode = FLAOAO - Intervention mode
|20230114 01:49:43 Failure: Rerotator tracking out of ramge FLAO, star mag= 15.2, posXY= -0.1, 0.0 mm, mode = FLAOAO - Intervention mode
|20230114 01:52:09 Success FLAO, star mag= 15.2, posXY= -0.1, 0.0 mm, mode = FLAOAO - Intervention mode
|20230114 02:02:00 Success FLAO, star mag= 15.2, posXY= -0.1, 0.0 mm, mode = FLAOAO - Intervention mode
|20230114 02:03:36 Success FLAO, star mag= 15.2, posXY= -0.1, 0.0 mm, mode = FLAOAO - Intervention mode
|20230114 02:27:26 Success FLAO, star mag= 13.3, posXY= -0.1, -0.1 mm, mode = FLAOAO - Intervention mode
|20230114 02:41:06 Success FLAO, star mag= 15.2, posXY= -0.2, 0.3 mm, mode = FLAOAO - Intervention mode
|20230114 03:25:02 Success FLAO, star mag= 15.2, posXY= 0.9, 0.5 mm, mode = FLAOAO - Intervention mode

Acquire - StartAO sequences
Total: 6 - Success rate: 83%
|20230114 01:41:23 Failure: Command not completed
|20230114 01:54:00 Success
|20230114 02:04:16 Success
|20230114 02:30:49 Success
|20230114 02:42:50 Success
|20230114 03:26:31 Success

Pause - Offset - Resume sequences
Total: 54 - Success rate: 59%
|20230114 01:57:11 Failure: RETRY: Offset outside FoV limits. Target xyz is -91.25 376.36 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=12.05, Y=427.98 mm
|20230114 01:58:51 Failure: Illegal command for state AOArbitrator.Ready
|20230114 02:47:49 Failure: RETRY: Offset outside FoV limits. Target xyz is -71.87 191.67 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=-6.01, Y=242.92 mm
|20230114 02:49:25 Failure: RETRY: Offset outside FoV limits. Target xyz is -74.88 194.67 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=-3.01, Y=245.94 mm
|20230114 02:50:44 Failure: RETRY: Offset outside FoV limits. Target xyz is -68.89 197.71 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=-9.01, Y=248.95 mm
|20230114 02:52:02 Success X=-0.10, Y=-0.47 mm
|20230114 02:53:32 Success X=-0.46, Y=0.37 mm
|20230114 02:55:00 Success X=1.14, Y=-0.36 mm
|20230114 02:56:24 Success X=-0.27, Y=0.54 mm
|20230114 02:57:48 Failure: RETRY: Offset outside FoV limits. Target xyz is -71.87 194.69 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=-6.32, Y=245.87 mm
|20230114 02:59:14 Failure: RETRY: Offset outside FoV limits. Target xyz is -68.86 191.69 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=-9.32, Y=242.85 mm
|20230114 03:00:32 Success X=-0.82, Y=0.19 mm
|20230114 03:02:00 Success X=0.96, Y=0.14 mm
|20230114 03:03:26 Success X=-1.05, Y=-0.80 mm
|20230114 03:04:52 Success X=0.79, Y=0.78 mm
|20230114 03:06:18 Failure: RETRY: Offset outside FoV limits. Target xyz is -73.35 193.17 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=-4.70, Y=244.05 mm
|20230114 03:07:42 Failure: RETRY: Offset outside FoV limits. Target xyz is -70.37 196.20 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=-7.71, Y=247.07 mm
|20230114 03:09:00 Success X=0.26, Y=-0.59 mm
|20230114 03:10:27 Success X=-0.87, Y=-0.04 mm
|20230114 03:11:51 Success X=0.61, Y=0.07 mm
|20230114 03:13:17 Success X=-0.46, Y=0.67 mm
|20230114 03:14:41 Failure: RETRY: Offset outside FoV limits. Target xyz is -68.87 197.72 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=-8.76, Y=248.46 mm
|20230114 03:16:06 Failure: RETRY: Offset outside FoV limits. Target xyz is -75.75 382.84 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=-2.78, Y=433.62 mm
|20230114 03:17:29 Success X=-0.14, Y=-1.00 mm
|20230114 03:18:59 Success X=0.96, Y=0.60 mm
|20230114 03:20:19 Success X=-0.20, Y=-0.50 mm
|20230114 03:21:42 Success X=-0.39, Y=0.41 mm
|20230114 03:23:07 Failure: RETRY: Offset outside FoV limits. Target xyz is -71.84 194.69 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=-6.00, Y=245.94 mm
|20230114 03:30:46 Failure: RETRY: Offset outside FoV limits. Target xyz is -174.55 -410.05 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=99.28, Y=-358.01 mm
|20230114 03:32:21 Failure: RETRY: Offset outside FoV limits. Target xyz is -177.55 -413.11 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=102.30, Y=-361.06 mm
|20230114 03:33:43 Failure: RETRY: Offset outside FoV limits. Target xyz is -180.56 -416.17 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=105.32, Y=-364.11 mm
|20230114 03:35:00 Success X=-0.10, Y=-0.47 mm
|20230114 03:36:28 Success X=-0.46, Y=0.37 mm
|20230114 03:37:52 Success X=1.14, Y=-0.36 mm
|20230114 03:39:19 Success X=-0.27, Y=0.54 mm
|20230114 03:40:46 Failure: RETRY: Offset outside FoV limits. Target xyz is -177.55 -410.07 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=101.97, Y=-358.09 mm
|20230114 03:42:10 Failure: RETRY: Offset outside FoV limits. Target xyz is -180.55 -413.13 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=104.99, Y=-361.14 mm
|20230114 03:43:28 Success X=-0.82, Y=0.19 mm
|20230114 03:44:55 Success X=0.96, Y=0.14 mm
|20230114 03:46:23 Success X=-1.05, Y=-0.80 mm
|20230114 03:47:50 Success X=0.79, Y=0.78 mm
|20230114 03:49:15 Failure: RETRY: Offset outside FoV limits. Target xyz is -180.54 -413.13 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=105.11, Y=-361.45 mm
|20230114 03:50:41 Failure: RETRY: Offset outside FoV limits. Target xyz is -174.51 -416.12 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=99.10, Y=-364.47 mm
|20230114 03:51:58 Success X=0.26, Y=-0.59 mm
|20230114 03:53:24 Success X=-0.87, Y=-0.04 mm
|20230114 03:54:51 Success X=0.61, Y=0.07 mm
|20230114 03:56:18 Success X=-0.46, Y=0.67 mm
|20230114 03:57:44 Failure: RETRY: Offset outside FoV limits. Target xyz is -174.50 -417.64 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=99.55, Y=-366.11 mm
|20230114 03:59:09 Failure: RETRY: Offset outside FoV limits. Target xyz is -180.52 -420.73 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=105.58, Y=-369.17 mm
|20230114 04:00:25 Success X=-0.14, Y=-1.00 mm
|20230114 04:01:49 Success X=0.96, Y=0.60 mm
|20230114 04:03:17 Success X=-0.20, Y=-0.50 mm
|20230114 04:04:41 Success X=-0.39, Y=0.41 mm
|20230114 04:06:04 Failure: RETRY: Offset outside FoV limits. Target xyz is -177.52 -410.06 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=102.30, Y=-358.02 mm

Resume - Pause sequences
Total: 32 - Success rate: 100%
|20230114 02:52:18 Success
|20230114 02:53:47 Success
|20230114 02:55:13 Success
|20230114 02:56:34 Success
|20230114 03:00:47 Success
|20230114 03:02:13 Success
|20230114 03:03:40 Success
|20230114 03:05:04 Success
|20230114 03:09:13 Success
|20230114 03:10:37 Success
|20230114 03:12:05 Success
|20230114 03:13:27 Success
|20230114 03:17:45 Success
|20230114 03:19:08 Success
|20230114 03:20:29 Success
|20230114 03:21:52 Success
|20230114 03:35:12 Success
|20230114 03:36:38 Success
|20230114 03:38:05 Success
|20230114 03:39:32 Success
|20230114 03:43:41 Success
|20230114 03:45:08 Success
|20230114 03:46:36 Success
|20230114 03:48:02 Success
|20230114 03:52:11 Success
|20230114 03:53:37 Success
|20230114 03:55:04 Success
|20230114 03:56:30 Success
|20230114 04:00:35 Success
|20230114 04:02:03 Success
|20230114 04:03:27 Success
|20230114 04:04:51 Success

AcquireRefAO
Total: 6 - Success rate: 100%
|20230114 01:41:23 Success
|20230114 01:54:00 Success
|20230114 02:04:16 Success
|20230114 02:30:49 Success
|20230114 02:42:50 Success
|20230114 03:26:31 Success

StartAO
Total: 5 - Success rate: 100%
|20230114 01:56:46 Success
|20230114 02:14:56 Success
|20230114 02:36:38 Success
|20230114 02:47:23 Success
|20230114 03:30:20 Success

CenterStar
Total: 6 - Success rate: 100%
|20230114 01:41:28 Success
|20230114 01:54:04 Success
|20230114 02:04:19 Success
|20230114 02:30:52 Success
|20230114 02:43:00 Success
|20230114 03:26:42 Success

CenterPupils
Total: 7 - Success rate: 71%
|20230114 01:41:50 Unknown
|20230114 01:44:36 Unknown
|20230114 01:54:20 Success
|20230114 02:04:33 Success
|20230114 02:31:04 Success
|20230114 02:43:28 Success
|20230114 03:26:58 Success

CheckFlux
Total: 5 - Success rate: 100%
|20230114 01:55:17 Success
|20230114 02:05:39 Success
|20230114 02:31:56 Success
|20230114 02:44:46 Success
|20230114 03:27:49 Success
()
CloseLoop
Total: 5 - Success rate: 100%
|20230114 01:55:18 Success
|20230114 02:05:40 Success
|20230114 02:31:58 Success
|20230114 02:44:57 Success
|20230114 03:27:53 Success

OptimizeGain
Total: 5 - Success rate: 100%
|20230114 01:56:01 Success
|20230114 02:06:41 Success
|20230114 02:34:27 Success
|20230114 02:46:20 Success
|20230114 03:29:04 Success

ApplyOpticalGain
Total: 1 - Success rate: 100%
|20230114 02:35:57 Success

OffsetXY
Total: 53 - Success rate: 60%
|20230114 01:57:14 Failure: RETRY: Offset outside FoV limits. Target xyz is -91.25 376.36 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=12.05, Y=427.98 mm
|20230114 02:47:52 Failure: RETRY: Offset outside FoV limits. Target xyz is -71.87 191.67 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=-6.01, Y=242.92 mm
|20230114 02:49:28 Failure: RETRY: Offset outside FoV limits. Target xyz is -74.88 194.67 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=-3.01, Y=245.94 mm
|20230114 02:50:47 Failure: RETRY: Offset outside FoV limits. Target xyz is -68.89 197.71 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=-9.01, Y=248.95 mm
|20230114 02:52:05 Success X=-0.10, Y=-0.47 mm
|20230114 02:53:35 Success X=-0.46, Y=0.37 mm
|20230114 02:55:03 Success X=1.14, Y=-0.36 mm
|20230114 02:56:27 Success X=-0.27, Y=0.54 mm
|20230114 02:57:51 Failure: RETRY: Offset outside FoV limits. Target xyz is -71.87 194.69 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=-6.32, Y=245.87 mm
|20230114 02:59:17 Failure: RETRY: Offset outside FoV limits. Target xyz is -68.86 191.69 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=-9.32, Y=242.85 mm
|20230114 03:00:35 Success X=-0.82, Y=0.19 mm
|20230114 03:02:03 Success X=0.96, Y=0.14 mm
|20230114 03:03:30 Success X=-1.05, Y=-0.80 mm
|20230114 03:04:55 Success X=0.79, Y=0.78 mm
|20230114 03:06:21 Failure: RETRY: Offset outside FoV limits. Target xyz is -73.35 193.17 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=-4.70, Y=244.05 mm
|20230114 03:07:45 Failure: RETRY: Offset outside FoV limits. Target xyz is -70.37 196.20 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=-7.71, Y=247.07 mm
|20230114 03:09:03 Success X=0.26, Y=-0.59 mm
|20230114 03:10:31 Success X=-0.87, Y=-0.04 mm
|20230114 03:11:54 Success X=0.61, Y=0.07 mm
|20230114 03:13:20 Success X=-0.46, Y=0.67 mm
|20230114 03:14:44 Failure: RETRY: Offset outside FoV limits. Target xyz is -68.87 197.72 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=-8.76, Y=248.46 mm
|20230114 03:16:09 Failure: RETRY: Offset outside FoV limits. Target xyz is -75.75 382.84 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=-2.78, Y=433.62 mm
|20230114 03:17:32 Success X=-0.14, Y=-1.00 mm
|20230114 03:19:02 Success X=0.96, Y=0.60 mm
|20230114 03:20:22 Success X=-0.20, Y=-0.50 mm
|20230114 03:21:45 Success X=-0.39, Y=0.41 mm
|20230114 03:23:10 Failure: RETRY: Offset outside FoV limits. Target xyz is -71.84 194.69 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=-6.00, Y=245.94 mm
|20230114 03:30:49 Failure: RETRY: Offset outside FoV limits. Target xyz is -174.55 -410.05 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=99.28, Y=-358.01 mm
|20230114 03:32:24 Failure: RETRY: Offset outside FoV limits. Target xyz is -177.55 -413.11 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=102.30, Y=-361.06 mm
|20230114 03:33:46 Failure: RETRY: Offset outside FoV limits. Target xyz is -180.56 -416.17 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=105.32, Y=-364.11 mm
|20230114 03:35:03 Success X=-0.10, Y=-0.47 mm
|20230114 03:36:31 Success X=-0.46, Y=0.37 mm
|20230114 03:37:55 Success X=1.14, Y=-0.36 mm
|20230114 03:39:22 Success X=-0.27, Y=0.54 mm
|20230114 03:40:49 Failure: RETRY: Offset outside FoV limits. Target xyz is -177.55 -410.07 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=101.97, Y=-358.09 mm
|20230114 03:42:13 Failure: RETRY: Offset outside FoV limits. Target xyz is -180.55 -413.13 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=104.99, Y=-361.14 mm
|20230114 03:43:30 Success X=-0.82, Y=0.19 mm
|20230114 03:44:58 Success X=0.96, Y=0.14 mm
|20230114 03:46:26 Success X=-1.05, Y=-0.80 mm
|20230114 03:47:53 Success X=0.79, Y=0.78 mm
|20230114 03:49:18 Failure: RETRY: Offset outside FoV limits. Target xyz is -180.54 -413.13 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=105.11, Y=-361.45 mm
|20230114 03:50:44 Failure: RETRY: Offset outside FoV limits. Target xyz is -174.51 -416.12 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=99.10, Y=-364.47 mm
|20230114 03:52:01 Success X=0.26, Y=-0.59 mm
|20230114 03:53:27 Success X=-0.87, Y=-0.04 mm
|20230114 03:54:54 Success X=0.61, Y=0.07 mm
|20230114 03:56:21 Success X=-0.46, Y=0.67 mm
|20230114 03:57:47 Failure: RETRY: Offset outside FoV limits. Target xyz is -174.50 -417.64 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=99.55, Y=-366.11 mm
|20230114 03:59:12 Failure: RETRY: Offset outside FoV limits. Target xyz is -180.52 -420.73 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=105.58, Y=-369.17 mm
|20230114 04:00:28 Success X=-0.14, Y=-1.00 mm
|20230114 04:01:52 Success X=0.96, Y=0.60 mm
|20230114 04:03:20 Success X=-0.20, Y=-0.50 mm
|20230114 04:04:44 Success X=-0.39, Y=0.41 mm
|20230114 04:06:07 Failure: RETRY: Offset outside FoV limits. Target xyz is -177.52 -410.06 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=102.30, Y=-358.02 mm

OffsetZ
Total: 0 - Success rate: 0%

Pause
Total: 54 - Success rate: 100%
|20230114 01:57:11 Success
|20230114 01:58:51 Failure: Illegal command for state AOArbitrator.Ready
|20230114 02:47:49 Success
|20230114 02:49:25 Success
|20230114 02:50:44 Success
|20230114 02:52:02 Success
|20230114 02:53:32 Success
|20230114 02:55:00 Success
|20230114 02:56:24 Success
|20230114 02:57:48 Success
|20230114 02:59:14 Success
|20230114 03:00:32 Success
|20230114 03:02:00 Success
|20230114 03:03:26 Success
|20230114 03:04:52 Success
|20230114 03:06:18 Success
|20230114 03:07:42 Success
|20230114 03:09:00 Success
|20230114 03:10:27 Success
|20230114 03:11:51 Success
|20230114 03:13:17 Success
|20230114 03:14:41 Success
|20230114 03:16:06 Success
|20230114 03:17:29 Success
|20230114 03:18:59 Success
|20230114 03:20:19 Success
|20230114 03:21:42 Success
|20230114 03:23:07 Success
|20230114 03:30:46 Success
|20230114 03:32:21 Success
|20230114 03:33:43 Success
|20230114 03:35:00 Success
|20230114 03:36:28 Success
|20230114 03:37:52 Success
|20230114 03:39:19 Success
|20230114 03:40:46 Success
|20230114 03:42:10 Success
|20230114 03:43:28 Success
|20230114 03:44:55 Success
|20230114 03:46:23 Success
|20230114 03:47:50 Success
|20230114 03:49:15 Success
|20230114 03:50:41 Success
|20230114 03:51:58 Success
|20230114 03:53:24 Success
|20230114 03:54:51 Success
|20230114 03:56:18 Success
|20230114 03:57:44 Success
|20230114 03:59:09 Success
|20230114 04:00:25 Success
|20230114 04:01:49 Success
|20230114 04:03:17 Success
|20230114 04:04:41 Success
|20230114 04:06:04 Success

Resume
Total: 32 - Success rate: 100%
|20230114 02:52:18 Success
|20230114 02:53:47 Success
|20230114 02:55:13 Success
|20230114 02:56:34 Success
|20230114 03:00:47 Success
|20230114 03:02:13 Success
|20230114 03:03:40 Success
|20230114 03:05:04 Success
|20230114 03:09:13 Success
|20230114 03:10:37 Success
|20230114 03:12:05 Success
|20230114 03:13:27 Success
|20230114 03:17:45 Success
|20230114 03:19:08 Success
|20230114 03:20:29 Success
|20230114 03:21:52 Success
|20230114 03:35:12 Success
|20230114 03:36:38 Success
|20230114 03:38:05 Success
|20230114 03:39:32 Success
|20230114 03:43:41 Success
|20230114 03:45:08 Success
|20230114 03:46:36 Success
|20230114 03:48:02 Success
|20230114 03:52:11 Success
|20230114 03:53:37 Success
|20230114 03:55:04 Success
|20230114 03:56:30 Success
|20230114 04:00:35 Success
|20230114 04:02:03 Success
|20230114 04:03:27 Success
|20230114 04:04:51 Success

PowerOnAdSec
Total: 0 - Success rate: 0%

PresetFlat
Total: 9 - Success rate: 55%
|20230114 00:31:15 Success
|20230114 01:28:02 Success
|20230114 04:11:53 Failure: LoadShape: WARNING - adsecarb:Illegal command for state Ready (Load shape)
|20230114 04:18:54 Failure: LoadShape: WARNING - adsecarb:Illegal command for state Ready (Load shape)
|20230114 04:26:45 Success
|20230114 04:28:33 Success
|20230114 04:39:27 Success
|20230114 10:50:13 Failure: LoadShape: WARNING - adsecarb:Illegal command for state Ready (Load shape)
|20230114 10:51:37 Failure: LoadShape: WARNING - adsecarb:Illegal command for state Ready (Load shape)

MirrorRest
Total: 0 - Success rate: 0%

All logs in temporal order.

Time Command Ex. time (s) Result Details More details
20230114 00:31:15 PresetFlat 2.5 s Success    
20230114 01:28:02 PresetFlat 2.6 s Success
20230114 01:37:01 PresetAO 72.2 s Success FLAO, star mag= 15.2, posXY= -0.1, 0.0 mm, mode = FLAOAO Intervention mode
20230114 01:41:23 AcquireRefAO 0.0 s Success
20230114 01:41:28 CenterStar 14.9 s Success
20230114 01:41:50 CenterPupils Unknown
20230114 01:44:36 CenterPupils Unknown
20230114 01:45:30 RIP Detected by [[FastDiagnostic][FastDiagnostic ]]
20230114 01:48:27 FailedActuator Act: 569 - Failing actuator detected N. 569 Value: 0.267411 on position (CHDISTAVERAGE-0569)
20230114 01:49:43 PresetAO 46.6 s Rerotator tracking out of ramge FLAO, star mag= 15.2, posXY= -0.1, 0.0 mm, mode = FLAOAO Intervention mode
20230114 01:52:09 PresetAO 21.1 s Success FLAO, star mag= 15.2, posXY= -0.1, 0.0 mm, mode = FLAOAO Intervention mode
20230114 01:54:00 AcquireRefAO 166.1 s Success
20230114 01:54:04 CenterStar 14.0 s Success
20230114 01:54:20 CenterPupils 55.2 s Success
20230114 01:55:17 CheckFlux 1.8 s Success
20230114 01:55:18 CloseLoop 37.7 s Success
20230114 01:56:01 OptimizeGain 38.9 s Success
20230114 01:56:46 StartAO 0.0 s Success
20230114 01:57:11 Pause 0.2 s Success
20230114 01:57:14 OffsetXY 0.0 s RETRY: Offset outside FoV limits. Target xyz is -91.25 376.36 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=12.05, Y=427.98 mm
20230114 01:58:51 Pause 0.0 s Illegal command for state AOArbitrator.Ready
20230114 02:02:00 PresetAO 11.6 s Success FLAO, star mag= 15.2, posXY= -0.1, 0.0 mm, mode = FLAOAO Intervention mode
20230114 02:03:36 PresetAO 24.5 s Success FLAO, star mag= 15.2, posXY= -0.1, 0.0 mm, mode = FLAOAO Intervention mode
20230114 02:04:16 AcquireRefAO 640.6 s Success
20230114 02:04:19 CenterStar 13.9 s Success
20230114 02:04:33 CenterPupils 51.0 s Success
20230114 02:05:39 CheckFlux 1.7 s Success
20230114 02:05:40 CloseLoop 36.4 s Success
20230114 02:06:41 OptimizeGain 34.2 s Success
20230114 02:14:56 StartAO 0.0 s Success
20230114 02:27:26 PresetAO 50.2 s Success FLAO, star mag= 13.3, posXY= -0.1, -0.1 mm, mode = FLAOAO Intervention mode
20230114 02:30:49 AcquireRefAO 349.5 s Success
20230114 02:30:52 CenterStar 8.9 s Success
20230114 02:31:04 CenterPupils 51.5 s Success
20230114 02:31:56 CheckFlux 1.7 s Success
20230114 02:31:58 CloseLoop 37.3 s Success
20230114 02:34:27 OptimizeGain 71.9 s Success
20230114 02:35:57 ApplyOpticalGain 35.3 s Success
20230114 02:36:38 StartAO 0.0 s Success
20230114 02:41:06 PresetAO 49.2 s Success FLAO, star mag= 15.2, posXY= -0.2, 0.3 mm, mode = FLAOAO Intervention mode
20230114 02:42:50 AcquireRefAO 272.9 s Success
20230114 02:43:00 CenterStar 14.6 s Success
20230114 02:43:28 CenterPupils 46.6 s Success
20230114 02:44:46 CheckFlux 1.7 s Success
20230114 02:44:57 CloseLoop 54.1 s Success
20230114 02:46:20 OptimizeGain 37.7 s Success
20230114 02:47:23 StartAO 0.0 s Success
20230114 02:47:49 Pause 0.1 s Success
20230114 02:47:52 OffsetXY 0.0 s RETRY: Offset outside FoV limits. Target xyz is -71.87 191.67 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=-6.01, Y=242.92 mm
20230114 02:49:25 Pause 0.0 s Success
20230114 02:49:28 OffsetXY 0.0 s RETRY: Offset outside FoV limits. Target xyz is -74.88 194.67 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=-3.01, Y=245.94 mm
20230114 02:50:44 Pause 0.0 s Success
20230114 02:50:47 OffsetXY 0.0 s RETRY: Offset outside FoV limits. Target xyz is -68.89 197.71 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=-9.01, Y=248.95 mm
20230114 02:52:02 Pause 0.0 s Success
20230114 02:52:05 OffsetXY 3.1 s Success X=-0.10, Y=-0.47 mm
20230114 02:52:18 Resume 0.1 s Success
20230114 02:53:32 Pause 0.3 s Success
20230114 02:53:35 OffsetXY 2.4 s Success X=-0.46, Y=0.37 mm
20230114 02:53:47 Resume 0.2 s Success
20230114 02:55:00 Pause 0.1 s Success
20230114 02:55:03 OffsetXY 2.7 s Success X=1.14, Y=-0.36 mm
20230114 02:55:13 Resume 0.2 s Success
20230114 02:56:24 Pause 0.1 s Success
20230114 02:56:27 OffsetXY 2.9 s Success X=-0.27, Y=0.54 mm
20230114 02:56:34 Resume 0.1 s Success
20230114 02:57:48 Pause 0.5 s Success
20230114 02:57:51 OffsetXY 0.0 s RETRY: Offset outside FoV limits. Target xyz is -71.87 194.69 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=-6.32, Y=245.87 mm
20230114 02:59:14 Pause 0.0 s Success
20230114 02:59:17 OffsetXY 0.0 s RETRY: Offset outside FoV limits. Target xyz is -68.86 191.69 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=-9.32, Y=242.85 mm
20230114 03:00:32 Pause 0.0 s Success
20230114 03:00:35 OffsetXY 3.4 s Success X=-0.82, Y=0.19 mm
20230114 03:00:47 Resume 0.1 s Success
20230114 03:02:00 Pause 0.3 s Success
20230114 03:02:03 OffsetXY 2.0 s Success X=0.96, Y=0.14 mm
20230114 03:02:13 Resume 0.3 s Success
20230114 03:03:26 Pause 0.7 s Success
20230114 03:03:30 OffsetXY 4.2 s Success X=-1.05, Y=-0.80 mm
20230114 03:03:40 Resume 0.4 s Success
20230114 03:04:52 Pause 0.6 s Success
20230114 03:04:55 OffsetXY 3.2 s Success X=0.79, Y=0.78 mm
20230114 03:05:04 Resume 0.1 s Success
20230114 03:06:18 Pause 0.1 s Success
20230114 03:06:21 OffsetXY 0.0 s RETRY: Offset outside FoV limits. Target xyz is -73.35 193.17 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=-4.70, Y=244.05 mm
20230114 03:07:42 Pause 0.0 s Success
20230114 03:07:45 OffsetXY 0.0 s RETRY: Offset outside FoV limits. Target xyz is -70.37 196.20 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=-7.71, Y=247.07 mm
20230114 03:09:00 Pause 0.0 s Success
20230114 03:09:03 OffsetXY 2.7 s Success X=0.26, Y=-0.59 mm
20230114 03:09:13 Resume 0.8 s Success
20230114 03:10:27 Pause 0.3 s Success
20230114 03:10:31 OffsetXY 3.8 s Success X=-0.87, Y=-0.04 mm
20230114 03:10:37 Resume 0.7 s Success
20230114 03:11:51 Pause 0.2 s Success
20230114 03:11:54 OffsetXY 4.5 s Success X=0.61, Y=0.07 mm
20230114 03:12:05 Resume 0.2 s Success
20230114 03:13:17 Pause 0.8 s Success
20230114 03:13:20 OffsetXY 2.4 s Success X=-0.46, Y=0.67 mm
20230114 03:13:27 Resume 0.2 s Success
20230114 03:14:41 Pause 0.3 s Success
20230114 03:14:44 OffsetXY 0.0 s RETRY: Offset outside FoV limits. Target xyz is -68.87 197.72 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=-8.76, Y=248.46 mm
20230114 03:16:06 Pause 0.0 s Success
20230114 03:16:09 OffsetXY 0.0 s RETRY: Offset outside FoV limits. Target xyz is -75.75 382.84 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=-2.78, Y=433.62 mm
20230114 03:17:29 Pause 0.0 s Success
20230114 03:17:32 OffsetXY 4.5 s Success X=-0.14, Y=-1.00 mm
20230114 03:17:45 Resume 0.2 s Success
20230114 03:18:59 Pause 0.2 s Success
20230114 03:19:02 OffsetXY 3.3 s Success X=0.96, Y=0.60 mm
20230114 03:19:08 Resume 0.1 s Success
20230114 03:20:19 Pause 0.1 s Success
20230114 03:20:22 OffsetXY 4.4 s Success X=-0.20, Y=-0.50 mm
20230114 03:20:29 Resume 0.1 s Success
20230114 03:21:42 Pause 0.1 s Success
20230114 03:21:45 OffsetXY 3.0 s Success X=-0.39, Y=0.41 mm
20230114 03:21:52 Resume 0.1 s Success
20230114 03:23:07 Pause 0.2 s Success
20230114 03:23:10 OffsetXY 0.0 s RETRY: Offset outside FoV limits. Target xyz is -71.84 194.69 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=-6.00, Y=245.94 mm
20230114 03:25:02 PresetAO 48.9 s Success FLAO, star mag= 15.2, posXY= 0.9, 0.5 mm, mode = FLAOAO Intervention mode
20230114 03:26:31 AcquireRefAO 229.0 s Success
20230114 03:26:42 CenterStar 14.2 s Success
20230114 03:26:58 CenterPupils 47.1 s Success
20230114 03:27:49 CheckFlux 1.7 s Success
20230114 03:27:53 CloseLoop 65.7 s Success
20230114 03:29:04 OptimizeGain 57.3 s Success
20230114 03:30:20 StartAO 0.0 s Success
20230114 03:30:46 Pause 0.2 s Success
20230114 03:30:49 OffsetXY 0.0 s RETRY: Offset outside FoV limits. Target xyz is -174.55 -410.05 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=99.28, Y=-358.01 mm
20230114 03:32:21 Pause 0.0 s Success
20230114 03:32:24 OffsetXY 0.0 s RETRY: Offset outside FoV limits. Target xyz is -177.55 -413.11 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=102.30, Y=-361.06 mm
20230114 03:33:43 Pause 0.0 s Success
20230114 03:33:46 OffsetXY 0.0 s RETRY: Offset outside FoV limits. Target xyz is -180.56 -416.17 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=105.32, Y=-364.11 mm
20230114 03:35:00 Pause 0.0 s Success
20230114 03:35:03 OffsetXY 4.4 s Success X=-0.10, Y=-0.47 mm
20230114 03:35:12 Resume 0.2 s Success
20230114 03:36:28 Pause 0.2 s Success
20230114 03:36:31 OffsetXY 3.6 s Success X=-0.46, Y=0.37 mm
20230114 03:36:38 Resume 0.2 s Success
20230114 03:37:52 Pause 0.2 s Success
20230114 03:37:55 OffsetXY 3.9 s Success X=1.14, Y=-0.36 mm
20230114 03:38:05 Resume 0.2 s Success
20230114 03:39:19 Pause 0.2 s Success
20230114 03:39:22 OffsetXY 2.7 s Success X=-0.27, Y=0.54 mm
20230114 03:39:32 Resume 0.2 s Success
20230114 03:40:46 Pause 0.2 s Success
20230114 03:40:49 OffsetXY 0.0 s RETRY: Offset outside FoV limits. Target xyz is -177.55 -410.07 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=101.97, Y=-358.09 mm
20230114 03:42:10 Pause 0.0 s Success
20230114 03:42:13 OffsetXY 0.0 s RETRY: Offset outside FoV limits. Target xyz is -180.55 -413.13 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=104.99, Y=-361.14 mm
20230114 03:43:28 Pause 0.0 s Success
20230114 03:43:30 OffsetXY 3.3 s Success X=-0.82, Y=0.19 mm
20230114 03:43:41 Resume 0.2 s Success
20230114 03:44:55 Pause 0.2 s Success
20230114 03:44:58 OffsetXY 2.9 s Success X=0.96, Y=0.14 mm
20230114 03:45:08 Resume 0.2 s Success
20230114 03:46:23 Pause 0.2 s Success
20230114 03:46:26 OffsetXY 3.5 s Success X=-1.05, Y=-0.80 mm
20230114 03:46:36 Resume 0.2 s Success
20230114 03:47:50 Pause 0.2 s Success
20230114 03:47:53 OffsetXY 3.8 s Success X=0.79, Y=0.78 mm
20230114 03:48:02 Resume 0.2 s Success
20230114 03:49:15 Pause 0.2 s Success
20230114 03:49:18 OffsetXY 0.0 s RETRY: Offset outside FoV limits. Target xyz is -180.54 -413.13 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=105.11, Y=-361.45 mm
20230114 03:50:41 Pause 0.0 s Success
20230114 03:50:44 OffsetXY 0.0 s RETRY: Offset outside FoV limits. Target xyz is -174.51 -416.12 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=99.10, Y=-364.47 mm
20230114 03:51:58 Pause 0.0 s Success
20230114 03:52:01 OffsetXY 3.9 s Success X=0.26, Y=-0.59 mm
20230114 03:52:11 Resume 0.2 s Success
20230114 03:53:24 Pause 0.2 s Success
20230114 03:53:27 OffsetXY 5.4 s Success X=-0.87, Y=-0.04 mm
20230114 03:53:37 Resume 0.2 s Success
20230114 03:54:51 Pause 0.2 s Success
20230114 03:54:54 OffsetXY 3.4 s Success X=0.61, Y=0.07 mm
20230114 03:55:04 Resume 0.2 s Success
20230114 03:56:18 Pause 0.2 s Success
20230114 03:56:21 OffsetXY 3.2 s Success X=-0.46, Y=0.67 mm
20230114 03:56:30 Resume 0.2 s Success
20230114 03:57:44 Pause 0.2 s Success
20230114 03:57:47 OffsetXY 0.0 s RETRY: Offset outside FoV limits. Target xyz is -174.50 -417.64 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=99.55, Y=-366.11 mm
20230114 03:59:09 Pause 0.0 s Success
20230114 03:59:12 OffsetXY 0.0 s RETRY: Offset outside FoV limits. Target xyz is -180.52 -420.73 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=105.58, Y=-369.17 mm
20230114 04:00:25 Pause 0.0 s Success
20230114 04:00:28 OffsetXY 3.9 s Success X=-0.14, Y=-1.00 mm
20230114 04:00:35 Resume 0.2 s Success
20230114 04:01:49 Pause 0.2 s Success
20230114 04:01:52 OffsetXY 3.7 s Success X=0.96, Y=0.60 mm
20230114 04:02:03 Resume 0.2 s Success
20230114 04:03:17 Pause 0.2 s Success
20230114 04:03:20 OffsetXY 4.6 s Success X=-0.20, Y=-0.50 mm
20230114 04:03:27 Resume 0.2 s Success
20230114 04:04:41 Pause 0.2 s Success
20230114 04:04:44 OffsetXY 3.3 s Success X=-0.39, Y=0.41 mm
20230114 04:04:51 Resume 0.2 s Success
20230114 04:06:04 Pause 0.2 s Success
20230114 04:06:07 OffsetXY 0.0 s RETRY: Offset outside FoV limits. Target xyz is -177.52 -410.06 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR X=102.30, Y=-358.02 mm
20230114 04:09:36 FailedActuator Act: 593 - Failing actuator detected N. 593 Value: 0.000430749 on position (CHDISTAVERAGE-0593)
20230114 04:11:53 PresetFlat 0.0 s LoadShape: WARNING - adsecarb:Illegal command for state Ready (Load shape)
20230114 04:18:54 PresetFlat 0.0 s LoadShape: WARNING - adsecarb:Illegal command for state Ready (Load shape)
20230114 04:26:45 PresetFlat 2.6 s Success
20230114 04:28:33 PresetFlat 2.7 s Success
20230114 04:39:27 PresetFlat 3.0 s Success
20230114 10:45:40 FailedActuator Act: 234 - Failing actuator detected N. 234 Value: 0.262892 on position (CHDISTAVERAGE-0234)
20230114 10:50:13 PresetFlat 0.0 s LoadShape: WARNING - adsecarb:Illegal command for state Ready (Load shape)
20230114 10:51:37 PresetFlat 0.0 s LoadShape: WARNING - adsecarb:Illegal command for state Ready (Load shape)
20230114 13:56:54 FailedActuator Act: 280 - Failing actuator detected N. 280 Value: 0.000173198 on position (CHDISTAVERAGE-0280)
-- JuanCarlosGuerra - 14 Jan 2023
Topic revision: r3 - 16 Jan 2023, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback