Columns added to record the source origin.

DATE INST SIDE X Y Z Rx Ry AOP source

temp

chamb

day before temp

chamber

notes
2021-01-15 LUCI SX -2.99 3.29 -1.02 -83 77 Greg   5 5  
2021-01-27 LUCI SX 2.99 3.29 -1.098 -107.6 -16.49 Greg   1 -2  
2021-01-29 LUCI SX 2.99 3.29 -1.098 -107.6 -16.49 Ales   2 5  
2021-02-11 LUCI SX 2.88 3.3 -1.1 -106 -22 Enr   1 1  
2021-02-15 LUCI SX 2.9 2.29 -1 -83 -19 Doug   -3 -1  
2021-02-19 LUCI SX 2.9 3.3 -1 -80 -0 Greg   2 -6  
2021-03-08 LUCI SX 2.9 3.8 -1.2 -110 -10 JCar   6 4  
2021-03-23 LUCI SX 2.9 3.8 -1 -110 -23 JCar   -2 -5  
2021-03-29 LUCI SX 2.9 3.8 -1 -110 -23 JCar   6 0  
2021-04-02 LUCI SX 2.9 3.8 -1.2 -170 20 JCar   7 7  
2021-04-05 LUCI SX 2.9 3.8 -1.2 -178 0 JCar   8 9  
2021-04-12 LUCI SX 2.9 3.8 -1.2 -170 10 JCar   6 6  
2021-04-16 LUCI SX 2.9 3.8 -1 -130 -10 JCar   3 3  
2021-04-21 LUCI SX 3.1 3.7 -1.1 -150 -27 JCar   4.5 5  
2021-04-27 LUCI SX 3.1 3.7 -1.2 -148 28 JCar   4 6  
2021-05-07 LUCI SX 3.1 3.7 -1.2 -148 28 JCar   11 12  
2021-05-10 LUCI SX 3.1 3.7 -1.26 -144 37 JCar   7 7  
2021-06-23 LUCI SX 3.5 2.9 -1.4 -88 104 JCar   18 18  
2021-08-23 LUCI SX 3.5 1.9 -1.4 80 -130 JCar   17 16 after SSD
2021-09-03 LUCI SX 2.58 1.6 -1.53 108 -105 JCar   14 18 open loop coma correction
2021-10-20 LUCI SX 2.38 1.6 -1.24 187 -202 JCar   8 8  
2021-12-07 LUCI SX 2.38 1.34 -1.3 193 -220 JCar        
2022-01-14 LUCI SX 2.38 1.34 -1.25 196 -214 JCar   4 4  
2022-01-25 LUCI SX 2.34 1.38 -1.25 193 -220 JCar        
2022-02-10 luci SX 2.34 1.38 -1.1 198 -208 JCar        
2022-03-04 LUCI SX 2.38 1.38 -1.3 222 -196 JCar        
2022-06-08 LUCI SX 2.38 1.38 -1.5 150 -190 JCar ACU 15 15  
2022-06-24 LUCI sx 2.38 1.38 -1.4 190 -190 JCar ACU 17 17  
2022-07-01 LUCI SX 2.38 1.38 -1.4 180 -190 JCar   17 17  
2022-09-03 LUCI SX 2.33 1.33 -1.43 160 -170 JCar ACU     after SSD, adsec+M3 installation
2022-09-05 LCUI SX 2.33 1.29 -1.38 137 -187 JCar ACU      
2022-09-06 LUCI SX 3.2 2.7 -1.44 78 -63 JCar ACU      
2022-09-12 LUCI SX 2.79 0.8 -1.4 100 -131 GT ACU     ncpa meas
2022-10-02 LUCI SX 2.79 0.8 -1.348 120 -121 JCar ACU 11.3 11.3  
2022-10-29 LUCI SX 2.79 0.8 -1.18 155 -125 JCAR ACU 8 8 no corrected for extra aberrations of coma mode #7,#8 (-500 and -500)
2022-10-29 LUCI SX 2.79 0.8 -1.18 155 -125 jcar ACU 8 8  
2022-10-29 LUCI SX 3.16 2.38 -1.11 -6.5 -93 DM ACU      
2022-11-24 LUCI SX 3.7 2.5 -0.95 26 -110 JCAR ACu -4 -4 corrected some coma.
2022-11-28 LUCI DX -2.55 -1.6 1.45 -150 -200 GT&JCG ACU -4 -4 First alignment.Starting SOUL-DX comm
2022-12-01 LUCI DX -0.8 0.4 -0.7 -243 -45 GT&JCG RR -4 -4 RR DX COMM
2022-12-05 LUCI DX -0.9 1.3 -0.71 -238 -3.5 JGU RR 2 2 RR DX COMM
2022-12-06 LUCI DX -2.55 -1.6 1.34 -178 -232 JGU ACU 2 2 DX COMM
2022-12-09 LUCI SX 3.7 2.5 -1.24 -50 -65 DM ACU -1 -1  
2022-12-14 LUCI SX 3.7 2.5 -1.13 -42 -62 jgu ACU -2 -2  
2022-12-20 LUCI DX -2.55 -1.6 1.41 -185 -220 JGU ACU 3 3  
2023-01-03 LUCI SX 3.97 2.43 -1.21 -29 -31 JCGU ACU 1 1  
2023-01-20 LUCI DX -1.83 0.99 -0.45 -268 -92 JGU RR 0.2 0.2 DX SOUL COMM
2023-01-26 LUCI DX -2.73 -0.66 1.61 -235 -239 JGU ACU 0.1 0.1  
2023-01-31 LUCI DX -2.87 -1.0 1.49 -193 -251 JGU ACU -2 -2 DAYTIME work
2023-02-04 LUCI SX 3.5 2.0 -1.22 9 -75 JGU ACU 3.7 3. daytime
2023-02-13 LUCI DX -2.73 -0.66 1.4 -235 -239 JGU ACU -1.71 -1 daytime
2023-02-20 LUCI DX -2.7 -1.66 1.44 -187 -236 JGU ACU 4.4   MIDNIGHT
2023-02-21 LUCI DX -2.73 -1.66 1.28 -175 -245 JGU ACU 3.2   MIDNIGHT
2023-02-22 LUCI SX 3.97 2.43 -1.22 -30 -31 JGU ACU 1.4 3.2 EVENING
2023-02-27 SHARK-NIR SX 0.8 0.4 -1.19 299 -715 jgu acu     daytime
2023-03-06 LUCI SX 3.4 2.4 -1.12 -44 -90 JGU ACU 1 1 daytime
2023-03-10 luci sx 3.6 2.4 -1.17 -32 -50 jgu acu 4.5 4.5 daytime
2023-03-15 LUCI DX -2.73 -1.66 1.35 -169 -232 JGU ACU 2.84 2.5 daytime,
2023-04-15 SHARK SX 0.69 0.677 -1.35 282 -689 JP ACU     daytime, bayside 65.77, 20.283, 62
2023-04-19 SHARK-NIR SX 0.8 0.4 -1.23 300 -685 JGU ACU     daytime bayside 65.77,20.28,62
2023-05-04 LUCI DX -2.73 -1.66 1.29 -170 -232 JGU ACU 3.2 3.2 daytime
2023-05-15 LUCI SX 3.6 2.4 -1.33 -32 -48 JGU ACU 7.8 7.8 daytime
2023-08-30 MODS2 DX -3.54 -1.67 0.4 -300 246 JP ACU     midnight - SL Flat check
2023-09-01 MODS1 SX 4.84 0.93 -1.92 36 257 JP ACU     midnight - SL flat check
2023-09-10 LUCI DX -2.73 -1.66 0.5 -160 310 JGU jgu 18.3 18.3 daytime, after SSD. To be confirmed withM3 pos wth Luci
2023-09-15 LBTI SX 0.8 0.6 -1.66 147 -607 jcg acu 15   daytime
2023-09-16 LBTI DX -4.83 -3 0.63 95 -250 JCG ACU 15   daytime
2023-10-01 LUCI SX 3.6 2.4 -1.52 -182 -12 JCG ACU 10.6 10.6 DAYTIME
2023-10-01 LBTI/SHARK DX -8.5 -4.8 0.56 240 -485 JCG ACU 10.6 10.6 LMIRCAM POS. DAYTIME
2023-10-13 IRTC SX 4.15 2.87 -1.52 -226 53 DLM ACU     PSF Stablization with IRTC
2023-10-19 IRTC SX 4.15 2.87 -1.62 -249 61 GET ACU     SX NCPA Tests with IRTC
2023-10-31 LUCI DX -5.52 -2.59 0.75 -10.5 58.9 GET ACU     DX NCPA with LUCI2
2023-11-06 LUCI DX -4.1 -1.9 0.68 -182 237 GET ACU     DX NCPA with LUCI2
2023-11-18 LBTI/Shark DX -5.7 -4.5 0.55 255 -198 JCG ACU 8 8 NCPA with Shark, bayside
2023-11-22 LBTI SX 0.8 0.6 1.45 145 -603 JCG ACU 4.6 4.6 daytme
2023-12-08 LBTI (proper) DX -7.62 -3.93 0.8 242 -478 JP ACU 1.1 1.1 daytime BCU47/DX LBTI WFS close loop check
2024-01-04 LUCI SX 4 2.4 -1.46 -180 -11 JCG ACU 1.5 1.5  
2024-01-08 LBTI(Shark-VIS) Shark-vis -4.7 -4.5 0.73 248 -64 jcg acu -5.2 -5.1 daytime
2024-01-23 LBTI SHARKNIR 0.8 0.4 -1.6 165 -595 jcg acu 6 6 DAYTIME
2024-01-25 luci SX 4 2.4 -1.6 -185 30 jcg acu 6 6 daytime
2024-02-02 LUCI DX -4.1 -1.9 0.706 -177.7 239.6 GT ACU      
2024-02-06 LUCI SX 4 2.4 -1.53 -185 30 JCG ACU 3 3 daytime
2024-02-29 LBTI DX -5.7 -4.5 0.66 250 -180 jcg acu 4.6 4 daytime
2024-03-23 sharkvis dx -4.7 -4.3 0.63 206 -70 jcg acu 3 3 daytime
2024-04-02 LBTI-Ilocater SX 0.8 1.33 -1.44 79.63 -617 JP ACU     daytime - baysides ilocArgos: 67, 21, 71.8
2024-04-10 LUCI DX -4.7 -1.9 0.79 -166 251 jcg acu 1.5 1.5 daytime
2024-05-10 irtc dx -4.7 -1.9 0.73 -180 217 JCG ACU     daytime