• Checkout svn elab_lib code from Arcetri repository:
svn co svn+ssh://obelix.arcetri.astro.it/4lbt/svn/AOSupervisor/trunk/idl/elab_lib ./elab_lib

  • Checkout svn oaa_lib code from Arcetri repository:
svn co svn+ssh://obelix.arcetri.astro.it/4lbt/svn/IdlTools/trunk ./idltools

  • Add elab_lib folder and idltools folder to the IDL PATH
  • Configure the environment variables:
    • $ADOPT_DATA
    • $ADOPT_ELAB
    • $ADOPT_PHASEMAPS

Environment variables

( Apologize: naming is wrong. Don't try to underdstand: $ADOPT_ELAB is a tmp folder, adsec_calib and adsec_data contains data of the entire FLAO system, not of AdSec alone)

$ADOPT_DATA must point to the root folder of the tree containing tracknums data and configurations. In $ADOPT_DATA the folders "adsec_calib" and "adsec_data" must exists.

$ADOPT_ELAB must point to a folder on which temporary files are stored. Better to have it on a local disk

$ADOPT_PHASEMAPS must point to a folder containing the phasemaps .sav files (typically named KL_vXX.sav)

Copying snapshot data and calibration data

  • Create the folder $ADOPT_DATA (must end with "_right", e.g. "/home/dlmiller/elab/data_right")
  • Create the corresponding "_left" folder (e.g. "/home/dlmiller/elab/data_left")
  • Copy data in $ADOPT_DATA. You want to have copy /local/towerdata/adsec_calib and /local/towerdata/adsec_data. As an example, copying tracking number of 20140513 from adsecsx must results in a folder called $ADOPT_DATA/towerdata/adsec_data/20140513/Data_20140513_215858
  • Copy calibration from /local/towerdata/adsec_calib/blabla... into $ADOPT_DATA/towerdata/adsec_calib/blabla...
  • Copy phasemaps (files named KL_vXX.save) from adsecdx:/local/phase_maps or adsecsx:/local/phase_maps

Configuration Examples

Please copy from legolas.arcetri.astro.it on which a gbrusa account (usual password) is available
gbrusa@legolas:~$ printenv | grep ADOPT
ADOPT_DATA=/home/gbrusa/LBT_data_right
ADOPT_PHASEMAPS=/home/gbrusa/phase_maps
ADOPT_ELAB=/home/gbrusa/elab_right
gbrusa@legolas:~$ ls -l /home/gbrusa/LBT_data_right/
total 4
drwxr-xr-x+ 1 50026 50026     212 Sep 15  2013 adsec_calib
drwxrwxr-x+ 1 50026 50026    6184 Apr 22 21:40 adsec_data

You may want to add the following to

 
export ADOPT_DATA=$HOME/LBT_data_right
export ADOPT_ELAB=$HOME/elab_right
export ADOPT_PHASEMAPS=$HOME/phase_maps
Topic revision: r3 - 22 May 2014, LorenzoBusoni