housekeeper.param

For details see CAN 641a006.pdf

# FamilyName : parameter name
# From : from act/board/crate
# To : to act/board/crate
# AlarmMin: negative alarm threshold
# WarnMin : negative warning threshold
# WarnMax: positive warning threshold
# AlarmMax: positive alarm threshold
# RunningMeanLen: running mean length (in seconds - 0 no running mean)
# CAF : consecutive allowed fault without alarm
# Enabled : ena/dis for enable/disable
# Slow: speed fast/slow. usually set to fast.

BCUCOOLERIN0TEMP 0 5 -inf -inf 40 80 0.0001 1 ena fast
BCUCOOLERIN1TEMP 0 5 -inf -inf 30 80 0.0001 1 ena fast
BCUCOOLEROUT0TEMP 0 5 -inf -inf inf inf 0.0001 1 ena fast
BCUCOOLEROUT1TEMP 0 5 -inf -inf inf inf 0.0001 1 ena fast
BCUCOOLERPRESSURE 0 5 -inf -inf inf inf 0.0001 1 ena fast
BCUCRATEID 0 5 0 0 inf inf 0.0001 0 ena fast
BCUCURRENTVCCA 0 5 -1 -1 6 6 0.0001 1 ena fast
BCUCURRENTVCCL 0 5 -1 -1 40 40 0.0001 1 ena fast
BCUCURRENTVCCP 0 5 -5 -4 15 18 0.0001 1 ena fast
BCUCURRENTVSSA 0 5 -6 -6 1 1 0.0001 1 ena fast
BCUCURRENTVSSP 0 5 -15 -12 1 1 0.0001 1 ena fast
BCUDECIMATIONFACTOR 0 5 0 0 inf inf 0.0001 0 ena fast
BCUDIGITALIOACPOWERFAULT0 0 5 -1 -1 1 1 0.0001 1 ena fast
BCUDIGITALIOACPOWERFAULT1 0 5 -1 -1 1 1 0.0001 1 ena fast
BCUDIGITALIOACPOWERFAULT2 0 5 -1 -1 1 1 0.0001 1 ena fast
BCUDIGITALIOBUSSYSFAULT 0 5 -1 -1 1 1 0.0001 1 ena fast
BCUDIGITALIOCRATEID 0 5 -1 -1 100 100 0.0001 1 ena fast
BCUDIGITALIOCRATEISMASTER 0 5 -1 -1 2 2 0.0001 1 ena fast
BCUDIGITALIODRIVERENABLED 0 5 -1 -1 2 2 0.0001 1 ena fast
BCUDIGITALIOICDISCONNECTED 0 5 -1 -1 2 2 0.0001 1 ena fast
BCUDIGITALIOOVERCURRENT 0 5 -1 -1 1 1 0.0001 1 ena fast
BCUDIGITALIOVCCFAULT 0 5 -1 -1 1 1 0.0001 1 ena fast
BCUENABLEMASTERDIAGNOSTIC 0 5 0 0 inf inf 0.0001 0 ena fast
BCUFRAMESCOUNTER 0 5 0 0 inf inf 0.0001 0 ena fast
BCUHUMIDITY 0 0 -inf -inf inf inf 0.0001 1 ena fast
BCUHUMIDITY 1 1 -inf -inf inf inf 0.0001 20 ena fast
BCUHUMIDITY 2 2 -inf -inf inf inf 10 20 ena fast
BCUHUMIDITY 3 4 -inf -inf inf inf 0.0001 1 dis fast
BCUHUMIDITY 5 5 -inf -inf inf inf 10 20 ena fast
BCUIPADDRESS 0 5 0 0 inf inf 0.0001 0 ena fast
BCULOCALCURRENTTHRESHOLD 0 5 0 0 65 70 0.0001 0 ena fast
BCULOGICRELEASE 0 5 0 0 inf inf 0.0001 0 ena fast
BCUPOWERBACKPLANESERIAL 0 5 0 0 17 17 0.0001 0 ena fast
BCUPOWERTEMP 0 5 -50 -50 45 55 0.0001 5 ena fast
BCUREMOTEIPADDRESS 0 5 0 0 inf inf 0.0001 0 ena fast
BCURESETSTATUSBUSDRIVERENABLE 0 5 -1 -1 2 2 0.0001 1 ena fast
BCURESETSTATUSBUSDRIVERENABLESTATUS 0 5 -1 -1 2 2 0.0001 1 ena fast
BCURESETSTATUSBUSPOWERFAULT 0 5 -1 -1 1 1 0.0001 1 ena fast
BCURESETSTATUSBUSPOWERFAULTCTRL 0 5 -1 -1 2 2 0.0001 1 ena fast
BCURESETSTATUSBUSRESET 0 5 -1 -1 2 2 0.0001 1 ena fast
BCURESETSTATUSDSPRESET 0 5 -1 -1 2 2 0.0001 1 ena fast
BCURESETSTATUSFLASHRESET 0 5 -1 -1 2 2 0.0001 1 ena fast
BCURESETSTATUSFPGARESET 0 5 -1 -1 2 2 0.0001 1 ena fast
BCURESETSTATUSPCIRESET 0 5 -1 -1 2 2 0.0001 1 ena fast
BCURESETSTATUSSYSTEMWATCHDOG 0 5 -1 -1 1 1 0.0001 1 ena fast
BCUSERIALNUMBER 0 5 0 0 inf inf 0.0001 0 ena fast
BCUSOFTWARERELEASE 0 5 0 0 inf inf 0.0001 0 ena fast
BCUSTRATIXTEMP 0 5 -50 -50 45 55 0.0001 5 ena fast
BCUTOTALCURRENTTHRESHOLDNEG 0 5 0 0 inf inf 0.0001 0 ena fast
BCUTOTALCURRENTTHRESHOLDPOS 0 5 0 0 inf inf 0.0001 0 ena fast
BCUVOLTAGEVCCA 0 5 11 11.5 14.5 15 0.0001 1 ena fast
BCUVOLTAGEVCCL 0 5 2.7 2.9 5 5.5 0.0001 1 ena fast
BCUVOLTAGEVCCP 0 5 10 10.5 13 13.5 0.0001 1 ena fast
BCUVOLTAGEVSSA 0 5 -15 -14.5 -11.5 -11 0.0001 1 ena fast
BCUVOLTAGEVSSP 0 5 -13.5 -13 -10.5 -10 0.0001 1 ena fast
BCUVPSET 0 5 0 0 inf inf 0.0001 0 ena fast
BCUWHOAMI 0 5 0 0 inf inf 0.0001 0 ena fast
CHECKDEWPOINT 0 0 -inf -inf inf inf 0.0001 1 ena fast
DEWPOINT 0 0 -inf -inf inf inf 0.0001 5 ena fast
DIAGNAPPFASTVARSCOUNTER 0 0 0 0 inf inf 0 0 ena fast
DSPADCGAIN 0 671 -inf -inf inf inf 0.0001 0 ena fast
DSPADCOFFSET 0 671 -inf -inf inf inf 0.0001 0 ena fast
DSPADCSPIGAIN 0 671 -inf -inf inf inf 0.0001 0 ena fast
DSPADCSPIOFFSET 0 671 -inf -inf inf inf 0.0001 0 ena fast
DSPBIASCOMMAND 0 671 -inf -inf inf inf 0 0 ena fast
DSPBIASCURRENT 0 671 -inf -inf inf inf 0 0 ena fast
DSPCMOLA 0 671 -inf -inf inf inf 0 0 ena fast
DSPCMOLB 0 671 -inf -inf inf inf 0 0 ena fast
DSPCOILCURRENT 0 671 -3 -2.5 2.5 3 0.0001 5 ena fast
DSPCOMMANDSKIPFRAME 0 167 -inf -inf inf inf 0 0 ena fast
DSPCONTROLCURRENT 0 671 -inf -inf inf inf 0 0 ena fast
DSPCONTROLENABLE 0 671 -inf -inf inf inf 0 0 ena fast
DSPDACGAIN 0 671 -inf -inf inf inf 0.0001 0 ena fast
DSPDACOFFSET 0 671 -inf -inf inf inf 0.0001 0 ena fast
DSPDIAGNOSTICRECORDLEN 0 83 0 0 inf inf 0.0001 0 ena fast
DSPDIAGNOSTICRECORDPTR 0 83 0 0 inf inf 0.0001 0 ena fast
DSPDISTANCE 0 671 -inf -inf inf inf 0 0 ena fast
DSPDISTTHRESHOLD 0 671 -inf -inf inf inf 0 0 ena fast
DSPDRIVERSTATUSBUSDRIVERENABLE 0 83 -1 -1 2 2 0.0001 1 ena fast
DSPDRIVERSTATUSBUSPOWERFAULT 0 83 -1 -1 2 2 0.0001 1 ena fast
DSPDRIVERSTATUSBUSPOWERFAULTCTRL 0 83 -1 -1 2 2 0.0001 1 ena fast
DSPDRIVERSTATUSDRIVERENABLE 0 671 -1 -1 2 2 0.0001 1 ena fast
DSPDRIVERSTATUSDSP0RESET 0 83 -1 -1 2 2 0.0001 1 ena fast
DSPDRIVERSTATUSDSP0WATCHDOGEXPIRED 0 83 -1 -1 2 2 0.0001 1 ena fast
DSPDRIVERSTATUSDSP1RESET 0 83 -1 -1 2 2 0.0001 1 ena fast
DSPDRIVERSTATUSDSP1WATCHDOGEXPIRED 0 83 -1 -1 2 2 0.0001 1 ena fast
DSPDRIVERSTATUSENABLEDSPWATCHDOG 0 83 -1 -1 2 2 0.0001 1 ena fast
DSPDRIVERSTATUSFLASHRESET 0 83 -1 -1 2 2 0.0001 1 ena fast
DSPDRIVERSTATUSFPGARESET 0 83 -1 -1 2 2 0.0001 1 ena fast
DSPDRIVERTEMP 0 7 -50 -15 45 80 0.0001 5 ena fast
DSPDRIVERTEMP 8 8 -50 -15 inf inf 5 1 ena fast
DSPDRIVERTEMP 9 19 -50 -15 45 80 0.0001 5 ena fast
DSPDRIVERTEMP 20 20 -50 -15 inf inf 5 1 ena fast
DSPDRIVERTEMP 21 67 -50 -15 45 80 0.0001 5 ena fast
DSPDRIVERTEMP 68 68 -50 -15 inf inf 5 1 ena fast
DSPDRIVERTEMP 69 83 -50 -15 45 80 0.0001 5 ena fast
DSPDSPSTEMP 0 83 -50 -15 45 80 0.0001 5 ena fast
DSPERRLOOPGAIN 0 671 -inf -inf inf inf 0 0 ena fast
DSPFFUDCURRENT 0 671 -inf -inf inf inf 0 0 ena fast
DSPFLOATADCVALUE 0 671 -inf -inf inf inf 0 0 ena fast
DSPFLOATDACVALUE 0 671 -inf -inf inf inf 0 0 ena fast
DSPFMOLA 0 671 -inf -inf inf inf 0 0 ena fast
DSPFMOLB 0 671 -inf -inf inf inf 0 0 ena fast
DSPFORCESKIPFRAME 0 167 -inf -inf inf inf 0 0 ena fast
DSPFULLBIASCMD 0 671 -inf -inf inf inf 0 0 ena fast
DSPFULLBIASCURR 0 671 -inf -inf inf inf 0 0 ena fast
DSPGLOBALCOUNTER 0 167 0 0 inf inf 0 0 ena fast
DSPLOGICRELEASE 0 83 0 0 inf inf 0.0001 0 ena fast
DSPMODALSKIPFRAME 0 167 -inf -inf inf inf 0 0 ena fast
DSPPOSCHECKCNT 0 671 -inf -inf inf inf 0.0001 1 ena fast
DSPPOSCOMMAND 0 671 -inf -inf inf inf 0 0 ena fast
DSPPOWERTEMP 0 7 -50 -15 45 55 0.0001 5 ena fast
DSPPOWERTEMP 8 8 -50 -50 inf inf 5 1 ena fast
DSPPOWERTEMP 9 83 -50 -15 45 55 0.0001 5 ena fast
DSPRDDIAGNOSTICRECORDPTR 0 83 0 0 inf inf 0.0001 0 ena fast
DSPSERIALNUMBER 0 83 0 0 inf inf 0.0001 0 ena fast
DSPSOFTWARERELEASE 0 83 0 0 inf inf 0.0001 0 ena fast
DSPSPEEDLOOPGAIN 0 671 -inf -inf inf inf 0 0 ena fast
DSPSTEPPTRPRESHAPERCMD 0 671 -inf -inf inf inf 0 0 ena fast
DSPSTEPPTRPRESHAPERCURR 0 671 -inf -inf inf inf 0 0 ena fast
DSPSTRATIXTEMP 0 83 -50 -15 45 55 5 10 ena fast
DSPWHOAMI 0 83 0 0 255 255 0.0001 0 ena fast
DSPWRDIAGNOSTICRECORDPTR 0 83 0 0 inf inf 0.0001 0 ena fast
EXTERNALHUMIDITY 0 0 -inf -inf inf inf 0.0001 5 ena fast
EXTERNALTEMPERATURE 0 0 -50 -15 20 30 0.0001 5 ena fast
FLUXRATEIN 0 0 -inf 5 20 inf 0.0001 1 ena fast
PSACCELENA 0 0 -inf -inf inf inf 0 0 ena fast
PSBLOCK 0 0 -inf -inf inf inf 0 0 ena fast
PSDIAGNSTORESDRAM 0 0 -inf -inf inf inf 0 0 ena fast
PSDISTURB 0 0 -inf -inf inf inf 0 0 ena fast
PSDSPSTORESDRAM 0 0 -inf -inf inf inf 0 0 ena fast
PSFLENABLED 0 0 -inf -inf inf inf 0 0 ena fast
PSLINEARIZESLOPES 0 0 -inf -inf inf inf 0 0 ena fast
PSNORM4 0 0 -inf -inf inf inf 0 0 ena fast
PSNORMALL 0 0 -inf -inf inf inf 0 0 ena fast
PSNORMCONST 0 0 -inf -inf inf inf 0 0 ena fast
PSOVSFRAME 0 0 -inf -inf inf inf 0 0 ena fast
PSSKIPFRAME 0 0 -inf -inf inf inf 0 0 ena fast
PSUSEACTUALPOS 0 0 -inf -inf inf inf 0 0 ena fast
SGNDSPSTEMP 0 0 -50 -15 45 55 5 1 dis fast
SGNDSPSTEMP 1 1 -50 -15 45 55 0.0001 5 ena fast
SGNDSPSTEMP 2 2 -50 -15 45 55 5 1 dis fast
SGNDSPSTEMP 3 3 -50 -15 45 55 0.0001 5 ena fast
SGNDSPSTEMP 4 4 -50 -15 45 55 5 1 dis fast
SGNDSPSTEMP 5 5 -50 -15 45 55 0.0001 5 ena fast
SGNLOGICRELEASE 0 5 0 0 inf inf 0.0001 0 ena fast
SGNPOWERTEMP 0 5 -50 -15 45 55 0.0001 5 ena fast
SGNSERIALNUMBER 0 5 0 0 inf inf 0.0001 0 ena fast
SGNSOFTWARERELEASE 0 5 0 0 inf inf 0.0001 0 ena fast
SGNSTRATIXTEMP 0 5 -50 -15 45 55 0.0001 5 ena fast
SGNWHOAMI 0 5 0 0 255 255 0.0001 0 ena fast
SWITCHCRATEID 0 0 0 0 inf inf 0.0001 0 ena fast
SWITCHDECIMATIONFACTOR 0 0 0 0 inf inf 0.0001 0 ena fast
SWITCHENABLEMASTERDIAGNOSTIC 0 0 0 0 inf inf 0.0001 0 ena fast
SWITCHFRAMESCOUNTER 0 0 0 0 inf inf 0.0001 0 ena fast
SWITCHIPADDRESS 0 0 0 0 inf inf 0.0001 0 ena fast
SWITCHLOGICRELEASE 0 0 0 0 inf inf 0.0001 0 ena fast
SWITCHMIRRFRAMESCOUNTER 0 0 -inf -inf inf inf 0 0 ena fast
SWITCHNUMCRCERR 0 0 -inf -inf inf inf 0 0 ena fast
SWITCHNUMFLTIMEOUT 0 0 -inf -inf inf inf 0 0 ena fast
SWITCHOFFLOADSELECTOR 0 0 -inf -inf inf inf 0 0 ena fast
SWITCHPENDINGSKIPFRAMECNT 0 0 -inf -inf inf inf 0 0 ena fast
SWITCHPOWERTEMP 0 0 -50 -10 50 60 0.0001 5 ena fast
SWITCHREMOTEIPADDRESS 0 0 0 0 inf inf 0.0001 0 ena fast
SWITCHSAFESKIPFRAMECNT 0 0 -inf -inf inf inf 0 0 ena fast
SWITCHSERIALNUMBER 0 0 0 0 inf inf 0.0001 0 ena fast
SWITCHSOFTWARERELEASE 0 0 0 0 inf inf 0.0001 0 ena fast
SWITCHSTRATIXTEMP 0 0 -50 -15 45 65 0.0001 5 ena fast
SWITCHWFSFRAMECOUNTER 0 0 -inf -inf inf inf 0 0 ena fast
SWITCHWFSGLOBALTIMEOUT 0 0 -inf -inf inf inf 0 0 ena fast
SWITCHWFSGLOBALTIMEOUTCNT 0 0 -inf -inf inf inf 0 0 ena fast
SWITCHWHOAMI 0 0 0 0 inf inf 0.0001 0 ena fast
TOTALCURRENTVCCP 0 5 -200 -200 200 200 0.0001 1 ena fast
TOTALCURRENTVP 0 5 -250 -250 250 250 0.0001 1 ena fast
TOTALCURRENTVSSP 0 5 -250 -250 1 1 0.0001 1 ena fast
WATERCOLDPLATEINLET 0 0 -50 -16 21 inf 0.0001 5 ena fast
WATERCOLDPLATEOUTLET 0 0 -50 -16 21 inf 0.0001 5 ena fast
WATERMAININLET 0 0 -50 -16 21 inf 0.0001 5 ena fast
WATERMAINOUTLET 0 0 -50 -16 21 inf 0.0001 5 ena fast
MEANDSPCOILCURRENT 0 0 -inf -inf inf inf 0 0 ena fast
HUBTEMP 0 0 -50 -50 100 100 0 0 ena fast
PBPLANETEMP 0 5 -50 -50 100 100 0 0 ena fast
CPTEMP 0 0 -50 -50 100 100 0 0 ena fast
RBODYTEMP 0 0 -50 -50 100 100 0 0 ena fast
INNERSTRTEMP 0 0 -50 -50 100 100 0 0 ena fast

And software internal variable:
DIAGNAPPFASTVARSCOUNTER 0 0 0 0 inf inf 0 0 ena fast
- DIAGNAPPFASTVARSRATE 0 0 0 0 inf inf 0 0 ena fast
DIAGNAPPFRAMECOUNTER 0 0 0 0 inf inf 0 0 ena fast
DIAGNAPPFRAMERATE 0 0 0 0 inf inf 0 0 ena fast
DIAGNAPPFRAMETIMESTAMP 0 0 0 0 inf inf 0 0 ena fast
DIAGNAPPINITTIMESTAMP 0 0 0 0 inf inf 0 0 ena fast
DIAGNAPPSLOWVARSCOUNTER 0 0 0 0 inf inf 0 0 ena fast
DIAGNAPPSLOWVARSRATE 0 0 0 0 inf inf 0 0 ena fast

-- %USERSIG{MarcoXompero - 2015-11-12}%

Comments

 
Topic revision: r1 - 12 Nov 2015, MarcoXompero
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback