fastdiagn.param

For details see CAN 641a006.pdf

# FamilyName : parameter name
# From : from act/board/crate
# To : to act/board/crate
# AlarmMin: negative alarm threshold
# WarnMin : negative warning threshold
# WarnMax: positive warning threshold
# AlarmMax: positive alarm threshold
# RunningMeanLen: running mean length (in seconds - 0 no running mean)
# CAF : consecutive allowed fault without alarm
# Enabled : ena/dis for enable/disable
# Slow: speed fast/slow. usually set to fast.

EXAMPLE:

# FamilyName From To AlarmMin WarnMin WarnMax AlarmMax RunningMeanLen CAF Enabled Slow
CHCURRAVERAGE 0 671 -0.79 -0.7 0.75 0.79 0 2 ena fast
CHCURRRMS 0 671 -1 -3e-14 0.5 0.5 0 0 ena fast
CHDISTAVERAGE 0 671 2e-06 2e-06 0.000125 0.000135 0 0 ena fast
CHDISTRMS 0 671 -1 -3e-14 3e-08 5e-02 0 0 ena fast
CHFFCOMMAND 0 671 -0.69 -0.3 0.3 0.69 0 0 ena fast
CHFFPURECURRENT 0 671 -0.69 -0.3 0.3 0.69 0 0 ena fast
CHINTCONTROLCURRENT 0 671 -0.69 -0.3 0.3 0.69 0 0 ena fast
CHNEWDELTACOMMAND 0 671 -0.69 -0.3 0.3 0.69 0 0 ena fast
COMMANDHISTORYPTR 0 0 0 0 inf inf 0 0 ena fast
MIRRORFRAMECOUNTER 0 0 0 0 inf inf 0 0 ena fast
MODES 0 671 -0.001 -0.001 0.001 0.001 0 0 ena fast
OFFLOADMODES 0 21 -inf -inf inf inf 1 0 ena fast
PARAMBLOCKACCELEROMETERS 0 0 -1 -1 2 2 0 1 ena fast
PARAMBLOCKBLOCKSELECTION 0 0 -1 -1 2 2 0 1 ena fast
PARAMBLOCKDELTACOMMAND 0 0 -1 -1 2 2 0 1 ena fast
PARAMBLOCKDIAGNSTORAGE 0 0 -1 -1 2 2 0 1 ena fast
PARAMBLOCKDISTURBENABLED 0 0 -1 -1 2 2 0 1 ena fast
PARAMBLOCKFASTLINK 0 0 -1 -1 2 2 0 1 ena fast
PARAMBLOCKOFFLOADBLOCK 0 0 -1 -1 2 2 0 1 ena fast
PARAMBLOCKSLOPELINEARIZE 0 0 -1 -1 2 2 0 1 ena fast
PARAMBLOCKSLOPELINEARIZEMETHOD 0 0 -1 -1 8 8 0 1 ena fast
SKIPFRAMERATE 0 0 -inf -inf inf inf 1 0 ena fast
SLOPES 0 1599 -inf -inf inf inf 0.1 0 ena fast
SWITCHACCELEROMETERCOEFF 0 2 -inf -inf inf inf 0.1 0 ena fast
SWITCHNUMFLCRCERR 0 0 -inf -inf inf inf 0 0 ena fast
SWITCHNUMFLTIMEOUT 0 0 -inf -inf inf inf 0 0 ena fast
SWITCHPENDINGSKIPCOUNTER 0 0 -inf -inf inf inf 0 0 ena fast
SWITCHSAFESKIPCOUNTER 0 0 -inf -inf inf inf 0 0 ena fast
SWITCHTIMESTAMP 0 0 -inf -inf inf inf 0 0 ena fast
SWITCHWFSGLOBALTIMEOUT 0 0 -inf -inf inf inf 0 0 ena fast
WFSFRAMECOUNTER 0 0 -2 -2 inf inf 0 0 ena fast
POSPISTON 0 0 -inf -inf inf inf 0.5 0 ena fast
CURRPISTON 0 0 -inf -inf inf inf 0.5 0 ena fast

And software internal variable:
DIAGNAPPFASTVARSCOUNTER 0 0 0 0 inf inf 0 0 ena fast
- DIAGNAPPFASTVARSRATE 0 0 0 0 inf inf 0 0 ena fast
DIAGNAPPFRAMECOUNTER 0 0 0 0 inf inf 0 0 ena fast
DIAGNAPPFRAMERATE 0 0 0 0 inf inf 0 0 ena fast
DIAGNAPPFRAMETIMESTAMP 0 0 0 0 inf inf 0 0 ena fast
DIAGNAPPINITTIMESTAMP 0 0 0 0 inf inf 0 0 ena fast
DIAGNAPPSLOWVARSCOUNTER 0 0 0 0 inf inf 0 0 ena fast
DIAGNAPPSLOWVARSRATE 0 0 0 0 inf inf 0 0 ena fast

-- %USERSIG{MarcoXompero - 2015-11-12}%