ARGOS CAL UNIT.

BIN1@1.7KHz

  • Disturbace set.
  • Filter H.
  • Exp time 3, NDIT=10
  • NCPA ON.
  • ROT ANGLE:341.

ONSKY BIN1

OSCO.

ONSKY BIN3

ONSKY BIN3@900Hz

FILTER Ks.

  • seeing DIMM 1"
  • Seeing DIMM 1.2"
  • | Tracknum | 20210303_125507 |
  • | nphotons/sub/fr | 102.931610 |
  • | Magnitude | 14.523803 |
  • | # Modes | 90 |
  • | Modal rec | Rec_20200922_150000.fits |
  • | Binning | 3 |
  • | Frequency [Hz] | 916 |
  • | Modulation | 3.000000 |
  • | FW1 | Dichroic 600-1000 nm |
  • | FW2 | empty |
  • | Gain minmax | 0.116478 0.293432 |
  • | Telescope elevation | 62.874738 |
  • | seeing from OL modes | 1.013298 |
  • | number of skipped frames | 0 |
  • | lambda [um] | 2.150000 |
  • | exptime [s] | 4.000000 |
  • | framerate [Hz] | 0.250000 |
  • | no. frames | 10 |
  • | SR SE | 0.416481 |
  • | LUCI dark | 20210303_130132.fits_cube.fits |

bin3_onsky_march03.png

BIN3@340Hz

  • DIMM 1"
  • | Tracknum | 20210303_121238 |
  • | nphotons/sub/fr | 71.956703 |
  • | Magnitude | 15.966411 |
  • | # Modes | 90 |
  • | Modal rec | Rec_20200922_153500.fits |
  • | Binning | 3 |
  • | Frequency [Hz] | 347 |
  • | Modulation | 3.000000 |
  • | FW1 | Dichroic 600-1000 nm |
  • | FW2 | empty |
  • | Gain minmax | 0.198390 0.571200 |
  • | Telescope elevation | 75.575044 |
  • | seeing from OL modes | 1.118729 |
  • | number of skipped frames | 0 |
  • | lambda [um] | 2.150000 |
  • | exptime [s] | 8.000000 |
  • | framerate [Hz] | 0.125000 |
  • | no. frames | 10 |
  • | SR SE | 0.270639 |
  • | LUCI dark | 20210303_121546.fits_cube.fits |

bin3_march03_onsly_slow.png

ONSKY BIN4@295.
  • DIMM 1"
  • Tracknum |20210303_115006
  • nphotons/sub/fr | 44.264847
  • Magnitude | 17.356693 |
  • # Modes | 54 |
  • Modal rec | Rec_20200923_180000.fits |
  • Binning | 4 |
  • Frequency [Hz] | 295 |
  • Modulation | 3.000000 |
  • FW1 | Dichroic 600-1000 nm |
  • FW2 | empty |
  • Gain minmax | 0.068751 0.190017 |
  • Telescope elevation | 71.698892 |
  • seeing from OL modes | 1.844215 |
  • number of skipped frames | 0 |
  • lambda [um] | 2.150000 |
  • exptime [s] | 20.000000 |
  • framerate [Hz] | 0.050000 |
  • no. frames | 10 |
  • SR SE | 0.058156 |
  • LUCI dark | 20210303_114905.fits_cube.fits

BIN4_MARCH3_ONSKY.png

   

bin4_march3_modalplot_slow.png

bin4_profile_march3.png

bin4_march3_plotjitter.png

BIN4@380Hz

  • DIMM 1"
  • | Tracknum | 20210303_084717 |
  • | nphotons/sub/fr | 58.805275 |
  • | Magnitude | 16.770542 |
  • | # Modes | 54 |
  • | Modal rec | Rec_20200923_180000.fits |
  • | Binning | 4 |
  • | Frequency [Hz] | 381 |
  • | Modulation | 3.000000 |
  • | FW1 | Dichroic 600-1000 nm |
  • | FW2 | empty |
  • | Gain minmax | 0.080655 0.152290 |
  • | Telescope elevation | 65.387430 |
  • | seeing from OL modes | 1.556099 |
  • | number of skipped frames | 0 |
  • | lambda [um] | 2.150000 |
  • | exptime [s] | 20.000000 |
  • | framerate [Hz] | 0.050000 |
  • | no. frames | 10 |
  • | SR SE | 0.122143 |
  • | LUCI dark | 20210303_085647.fits_cube.fits |
BIN4_MARCH3_FAST.png BIN4_MARCH3_MODALPLOT_FAST.png

TABLE ESM

Ref Mag Seeing Bin Freq emgains tt ho1 ho2 LUCI (luci1.20201229.) TN FWHM (arcsec)
10 0 1 100 20 6.82 0.45 0.08 35-37 082616 0.32, 0.33, 0.36
10 0.75 1 100 20 1.85 9.8 0.08 38-40 084018 0.43, 0.40, 0.41
10 1.0 1 100 20 10.8 14.48 0.08 41-43 085250 0.51, 0.45, 0.51
10 0 1 500 200 4.87 2.52 0.08 32-34 081131 0.33, 0.33, 0.33
10 0.75 1 500 200 9.16 8.94 0.08 29-31 080549 0.40, 0.41, 0.41
10 1.0 1 500 200 1.94 9.38 0.08 26-28 075913 0.47, 0.48, 0.46
12.5 0 2 100 600 0.09 0.67 0.08 56-58 095210 0.33, 0.33, 0.32
12.5 0 2 100 100 0.09 0.67 0.08 71-73 104133 0.30, 0.31, 0.33
12.5 0.75 2 100 100 1.84 13.44 0.08 59-61,65-67 103153 0.40, 0.41, 0.40, 0.40, 0.39, 0.40
12.5 1.0 2 100 100 2.3 13.89 0.08 62-64 101838 0.45, 0.47, 0.45
12.5 0 2 400 600 2.77 3.87 0.08 50-52 092315 0.31, 0.28, 0.29
12.5 0.75 2 400 600 2.70 9.59 0.08 47-49 091637 0.42, 0.41, 0.41
12.5 1.0 2 400 600 5.46 10.48 0.09 44-46 090851 0.47, 0.47, 0.48
13.9 0 2 100 600 2.67 12.55 0.08 113-115 123439 0.31, 0.31, 0.31
13.9 0.75 2 100 600 5.38 14.04 0.08 110-112 124557 0.42, 0.42, 0.42
13.9 1.0 2 100 600 9.03 8.25 0.08 107-109 125650 0.50, 0.49, 0.49
13.9 0 2 400 600 9.00 2.5 0.08 98-100 121158 0.32, 0.32, 0.32
13.9 0.75 2 400 600 2.80 5.44 0.08 101-103 121732 0.42, 0.42, 0.41
13.9 1.0 2 400 600 1.00 7.23 0.08 104-106 122335 0.48, 0.49, 0.50
14.9 0 4 100 300 0.42 0.53 0.10 92-94 111616 0.35, 0.33, 0.33
14.9 0.75 4 100 300 0.26 0.35 0.10 89-91 112148 0.44, 0.44, 0.44
14.9 1.0 4 100 300 0.09 0.09 0.10 86-88 112704 0.53, 0.50, 0.49
14.9 0 4 400 600 0.26 0.09 0.10 74-76 105546 0.30, 0.29, 0.29
14.9 0.75 4 400 600 0.59 0.27 0.10 77-79   0.40, 0.40, 0.40
14.9 1.0 4 400 600       80-82   0.46, 0.47, 0.48
17.0 0 4 100 600 0.9 0.09 0.10 20-21 071435 0.33, 0.32
17.0 0.75 4 100 600 0.9 0.36 0.10 22-23 72202 0.40, 0.41
17.0 1.0 4 100 600 0.28 0.45 0.10 24-25 072951 0.48, 0.50
17.0 0 4 200 600 0.42 0.09 0.10 18-19 065612 0.34, 0.35
17.0 0.75 4 200 600 0.46 0.34 0 10-11 061550 0.46, 0.48
17.0 1.0 4 200 600 0.26 0.36 0.1 14-17 065207 0.51, 0.51, 0.51, 0.56
Topic revision: r5 - 11 Jan 2022, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback