The IRC has defined to work with an specific focal station. When it request commands to move for example the rotator the IRC will report an error if the specific command associated to the focal station is not already loaded.

irc command to show the options:

[AOeng@soul-dxwfs scripts]$ irc -show
Proxy name: irc

IIF connections:
DIMM : DIMM at prime right
IRC : LBC at prime both
IRCL : PEPSIPFU at bentgregorianrearfiberfeed left
IRCR : PEPSIPFU at bentgregorianrearfiberfeed right
LBTI LBTO-INDI Gateway : LBTI at bentgregoriancenter both
LINC_LTCS_DX_IIF : LINC at bentgregorianback right
LINC_LTCS_SX_IIF : LINC at bentgregorianback left
Lucifer : LUCIFER at bentgregorianfront both
Lucifer ONE : LUCIFER at bentgregorianfront left
Lucifer TWO : LUCIFER at bentgregorianfront right
MODS1 : MODS at directgregorian left
MODS2 : MODS at directgregorian right
NSIGUI799 : IRTC at bentgregorianfront left
PEPSI_PFU_left : PEPSIPFU at bentgregorianrearfiberfeed left
PEPSI_PFU_right : PEPSIPFU at bentgregorianrearfiberfeed right
PEPSI_POL_left : PEPSIPOL at directgregorian left
PEPSI_POL_right : PEPSIPOL at directgregorian right
SHARK LBTO-INDI Gateway : SHARK at bentgregoriancenter both
argos : DIMM at prime right
irc : LUCIFER at bentgregorianfront left
pyiif : SHARK at bentgregoriancenter left

IRS is not running
----------------------------------------------
[AOeng@soul-dxwfs scripts]$

Register a new focal station.

irc -help register.

Example below to set focal station bent gregorian front and instrument luci:

irc register 'bentGregoriarnFront right' LUCIFER

[AOeng@soul-dxwfs scripts]$ irc register 'bentgregorianfront right' LUCIFER
Creating proxy irc for LUCIFER on bentgregorianfront right

[AOeng@soul-dxwfs scripts]$ irc -show
Proxy name: irc

IIF connections:
DIMM : DIMM at prime right
IRC : IRTC at bentgregorianfront left
IRCL : LUCIFER at bentgregorianfront left
IRCR : LUCIFER at bentgregorianfront right
LBTI LBTO-INDI Gateway : LBTI at bentgregoriancenter both
Lucifer : LUCIFER at bentgregorianfront both
Lucifer ONE : LUCIFER at bentgregorianfront left
Lucifer TWO : LUCIFER at bentgregorianfront right
MODS1 : MODS at directgregorian left
MODS2 : MODS at directgregorian right
PEPSI_PFU_left : PEPSIPFU at bentgregorianrearfiberfeed left
PEPSI_PFU_right : PEPSIPFU at bentgregorianrearfiberfeed right
PEPSI_POL_left : PEPSIPOL at directgregorian left
PEPSI_POL_right : PEPSIPOL at directgregorian right
SHARK LBTO-INDI Gateway : SHARK at bentgregoriancenter both
SHARK_LTCS_SX_IIF : SHARK at bentgregoriancenter left
irc : LUCIFER at bentgregorianfront right

-- JuanCarlosGuerra - 19 Jan 2023
Topic revision: r4 - 15 Mar 2023, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.