Automatic Dump Legend

In case of ASM failure, you should find an automatic diagnostics information dump generated by the Masterdiagnostic process and processed automatically by IDL.

In the masterdiagn..log , located in $ADOPT_ROOT on AOeng@adsecsx (@adsecdx) workstation, you should find the dump generation log:

masterdiagnostic.L |INF|      3303|2013-02-04 03:56:11.502537|             MAIN > OFramesHistory::dumpToFile: output file /local/aolog/current/ADAPTIVE-SECONDARY_00001359950171_20130204_035611_2.log
masterdiagnostic.L |INF|      3304|2013-02-04 03:56:11.502711|             MAIN > Dumping 1st part of size 52319628...
masterdiagnostic.L |INF|      3305|2013-02-04 03:56:11.606385|             MAIN > Dumping 2nd part of size 52372...
masterdiagnostic.L |INF|      3306|2013-02-04 03:56:11.613884|   ALERT-NOTIFIER > ArbitratorInterface to adsecarb.L succesfully created!
masterdiagnostic.L |INF|      3307|2013-02-04 03:56:11.614103|             MAIN > Alert for dump to adsec arbitrator successfully sent

To find the process requested the dump, you have to go inside the log of the single processes.

In the adsec..log file, located in $ADOPT_ROOT on AOeng@adsecsx (@adsecdx) workstation, you should find the processing result as the one reported here.

adsec.R            |INF|     15863|2013-01-28 01:28:47.162555|             MAIN > -- PROCESS DUMP START --
adsec.R            |INF|     15864|2013-01-28 01:28:47.162628|             MAIN > Mon Jan 28 01:28:47 2013
adsec.R            |INF|     15865|2013-01-28 01:28:47.902502|             MAIN > Get info from housekeeper.R variables...done
adsec.R            |INF|     15866|2013-01-28 01:28:48.155437|             MAIN > Get info from masterdiagnostic.R dump file: ADAPTIVE-SECONDARY_00001359336479_20130128_012759.log...dump loaded.
adsec.R            |INF|     15867|2013-01-28 01:28:48.294969|             MAIN > Get info from fastdiagn.R variables...done
adsec.R            |INF|     15868|2013-01-28 01:28:48.420180|             MAIN > Get info from fastdiagn.R variables...done
adsec.R            |INF|     15869|2013-01-28 01:28:49.298471|             MAIN > No variables in Alarm for family: CHCURRAVERAGE
adsec.R            |INF|     15870|2013-01-28 01:28:49.326737|             MAIN > No variables in Alarm for family: CHDISTAVERAGE
adsec.R            |INF|     15871|2013-01-28 01:28:49.354415|             MAIN > No variables in Alarm for family: CHINTCONTROLCURRENT
adsec.R            |INF|     15872|2013-01-28 01:28:49.381254|             MAIN > No variables in Alarm for family: CHDISTRMS
adsec.R            |INF|     15873|2013-01-28 01:28:49.407271|             MAIN > No variables in Alarm for family: CHCURRRMS
adsec.R            |INF|     15874|2013-01-28 01:28:49.435472|             MAIN > No variables in Alarm for family: MODES
adsec.R            |INF|     15875|2013-01-28 01:28:49.464802|             MAIN > No variables in Alarm for family: CHNEWDELTACOMMAND
adsec.R            |INF|     15876|2013-01-28 01:28:49.492995|             MAIN > No variables in Alarm for family: CHFFCOMMAND
adsec.R            |INF|     15877|2013-01-28 01:28:49.522312|             MAIN > No variables in Alarm for family: CHFFPURECURRENT
adsec.R            |INF|     15878|2013-01-28 01:28:52.327147|             MAIN > Get info from housekeeper.R variables configuration...done
adsec.R            |INF|     15879|2013-01-28 01:28:52.328484|             MAIN > Get info from adamhousekeeper.R variables...done
adsec.R            |INF|     15880|2013-01-28 01:28:53.088246|             MAIN > Get info from housekeeper.R variables...done
adsec.R            |INF|     15881|2013-01-28 01:28:53.089464|             MAIN > Get info from adamhousekeeper.R variables...done
adsec.R            |INF|     15882|2013-01-28 01:28:53.255949|             MAIN > Adam watchdog not expired.
adsec.R            |INF|     15883|2013-01-28 01:28:53.281443|             MAIN > Ethernet connection watchdog on Switch BCU not expired.
adsec.R            |INF|     15884|2013-01-28 01:28:53.294170|             MAIN > Ethernet connection watchdog on Crate BCU not expired.
adsec.R            |INF|     15885|2013-01-28 01:28:53.296498|             MAIN > All global counters are progressing
adsec.R            |INF|     15886|2013-01-28 01:28:53.314914|             MAIN > DSP board watchdog not expired.
adsec.R            |INF|     15887|2013-01-28 01:28:53.328226|             MAIN > Distance threshold check analysis result:
adsec.R            |INF|     15888|2013-01-28 01:28:53.328284|             MAIN > Not stable capacitive sensor on CH ID: 002 007 011 (times: 187419711971)
adsec.R            |INF|     15889|2013-01-28 01:28:53.328349|             MAIN > Consider to remove the actuators with highest fault frequency from the close loop list.
adsec.R            |INF|     15890|2013-01-28 01:28:53.328396|             MAIN > Consider to remove the other detected actuators from the integrator control loop list.
adsec.R            |INF|     15891|2013-01-28 01:28:53.347288|             MAIN > Temperature check passed with no issues found.
adsec.R            |INF|     15892|2013-01-28 01:28:53.455723|             MAIN > OVERCURRENT probability for TOTAL PUSH CURRENT:  38.7%
adsec.R            |INF|     15893|2013-01-28 01:28:53.455816|             MAIN > OVERCURRENT probability for TOTAL PULL CURRENT:   0.0%
adsec.R            |INF|     15894|2013-01-28 01:28:53.455905|             MAIN > OVERCURRENT probability for SINGLE CRATE TOTAL CURRENT:  20.5%
adsec.R            |INF|     15895|2013-01-28 01:28:53.455949|             MAIN > -- PROCESS DUMP END --

Now we will analyze any information we can retrieve from that.

GENERAL RULE: too much values means that the automatic procedure failed or the data are not reliable for that field

MAIN > Mon Jan 28 01:28:47 2013
MAIN > Get info from housekeeper.R variables...done
MAIN > Get info from masterdiagnostic.R dump file: ADAPTIVE-SECONDARY_00001359336479_20130128_012759.log...dump loaded.
MAIN > Get info from fastdiagn.R variables...done
MAIN > Get info from fastdiagn.R variables...done

No variables in Alarm for family: CHCURRAVERAGE

No variables in Alarm for family: CHDISTAVERAGE

MAIN > No variables in Alarm for family: CHINTCONTROLCURRENT

MAIN > No variables in Alarm for family: CHDISTRMS

MAIN > No variables in Alarm for family: CHCURRRMS

MAIN > No variables in Alarm for family: MODES

MAIN > No variables in Alarm for family: CHNEWDELTACOMMAND

MAIN > No variables in Alarm for family: CHFFCOMMAND

MAIN > No variables in Alarm for family: CHFFPURECURRENT

MAIN > Get info from housekeeper.R variables configuration...done

MAIN > Get info from adamhousekeeper.R variables...done

MAIN > Get info from housekeeper.R variables...done

MAIN > Get info from adamhousekeeper.R variables...done

MAIN > Adam watchdog not expired.

MAIN > Ethernet connection watchdog on Switch BCU not expired.

MAIN > Ethernet connection watchdog on Crate BCU not expired.

MAIN > All global counters are progressing

MAIN > DSP board watchdog not expired.

MAIN > Distance threshold check analysis result:

MAIN > Not stable capacitive sensor on CH ID: 002 007 011 (times: 187419711971)

MAIN > Consider to remove the actuators with highest fault frequency from the close loop list.

MAIN > Consider to remove the other detected actuators from the integrator control loop list.

MAIN > Temperature check passed with no issues found.

MAIN > OVERCURRENT probability for TOTAL PUSH CURRENT:  38.7%
MAIN > OVERCURRENT probability for TOTAL PULL CURRENT:   0.0%
MAIN > OVERCURRENT probability for SINGLE CRATE TOTAL CURRENT:  20.5%

-- MarcoXompero - 30 Jan 2013
Topic revision: r2 - 04 Feb 2013, MarcoXompero
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback