-- XianyuZhang - 30 Jan 2023

2023-01-31 - Test housekeeper timeout patch+RR on DX ASM

  • People: Xianyu, Guido, Brandon, Juan Carlos
  • Scripts used: None
  • Software versions used for test:
    • dxadsec: /home/aoeng/soul/checkout
    • soul-dxwfs: stable
  • Software version after test:
    • sxadsec: /home/aoeng/soul/mixed_mode_control
    • soul-dxwfs: stable

Background

Just verify the DX ASM with the changes for HK and RR on DX ASM.

Code changed

Please see the change in at GitHub.

Test and Results

A normal closed loop with non-zero-gain is planned, and the test plan steps and results are available in the google sheets, see link.

Topic revision: r2 - 31 Jan 2023, XianyuZhang