UT 20130920 AO#2 DX
Observer:DMiller, JChristou (LBTO)
Telescope Operator: GBechetti
SW Support: JKraus
AO Support: JChristou
Telescope Support: KNewton
Instrument Support: ESolheid
Summary
Details
01:30 w_stop, w_start
01:32 Power on WFS via AOS GUI
01:55 All systems (wfs and adsec) up, running and ready.
01:55 Geno preset to pointing star
02:10 Active preset has collimated the telescope
02:12 preset, AO734, MODE=ACE, GS=18, PA=0
02:18 runao. CCD39 stop (Not Live) when the low order closed loop is closed during the acquireRef phase.
02:20 runao. Same freezing of CCD39
04:00 Talked to Simone and Alfio. Powered off and on the WUnit. Had problems with CCD47 equalization.
- Click "Operate" button to get back to initial configuration
- In Variable inspector GUI set slopecompctrl.R.FASTLINK.ENABLE.REQ for 0 to 1. Close loop button turns green on WFS Control GUI. WFSFrameCounter increment on AdSec Mirror GUI. Communication is working
- While in Operate State can close the loop
- setting bin = 1, Loop freq = 990, lambda=3.0 and Apply.
- set gains to 0.0 on AdSec GUI.
- close loop on wfs control gui
- WFSFramecounter is changing
- iif_preset and iif_runao and loop is closed.
- Conclude that the power cycle of WUnit "fixed" it
Bin 1
04:30 preset AO728 bin 1
TrackNo |
RefStar |
Mag |
El |
Wind |
DIMM/OL |
Rec |
bin |
#mod |
freq |
gain |
mod |
nph |
AntiDrift |
SR |
filter |
exp |
#frames |
disturb |
SN |
notes |
20130920_043849 |
??? |
11.1 |
83 |
4 |
0.88 0.39 |
221257 |
2 |
153 |
991 |
1.2 0.5 0.5 |
3 |
81 |
ON |
71.9 |
H |
200 |
100 |
ONSKY |
zero.fits |
|
20130920_043918 |
??? |
11.1 |
83 |
4 |
0.85 0.40 |
221257 |
2 |
153 |
991 |
1.2 0.5 0.5 |
3 |
81 |
ON |
72.9 |
H |
200 |
100 |
ONSKY |
zero.fits |
|
20130920_043946 |
??? |
11.1 |
83 |
4 |
0.76 0.36 |
221257 |
2 |
153 |
991 |
1.2 0.5 0.5 |
3 |
81 |
ON |
70.0 |
H |
200 |
100 |
ONSKY |
zero.fits |
|
20130920_044106 |
??? |
11.1 |
82 |
4 |
0.78 0.43 |
221257 |
2 |
153 |
991 |
1.2 0.5 0.5 |
3 |
81 |
ON |
69.4 |
H |
200 |
100 |
ONSKY |
zero.fits |
|
20130920_044135 |
??? |
11.1 |
82 |
4 |
0.78 0.49 |
221257 |
2 |
153 |
991 |
1.2 0.5 0.5 |
3 |
81 |
ON |
63.6 |
H |
200 |
100 |
ONSKY |
zero.fits |
|
20130920_044203 |
??? |
11.1 |
82 |
4 |
0.79 0.48 |
221257 |
2 |
153 |
991 |
1.2 0.5 0.5 |
3 |
84 |
ON |
62.2 |
H |
200 |
100 |
ONSKY |
zero.fits |
|
SR |
0.683229 (0.044224) |
SEEING (WFS) |
0.425914 (0.0519231) |
SEEING (DIMM) |
0.804418 (0.0475647) |
04:45 preset AO731, Cat Mag = 12.2, WFS Mag = 11.8. Reset to bin 1, 990 hz. Want Bin 2
04:58 preset AO747, gs=4, pa=180, Cat Mag=13.5
05:02 runao. Failed because camera lens did not converge
05:10 preset and runao. Again failed because camera lens did not converge
Bin 2
05:20 preset AO747, gs=10, pa=0, Cat Mag=13.5
05:30 acq sky_irtc_psf
05:34 preset AO748, gs=3. runao. Closed, but bin2 Cat Mag = 14.4, WFS Mag = 12.2
TrackNo |
RefStar |
Mag |
El |
Wind |
DIMM/OL |
Rec |
bin |
#mod |
freq |
gain |
mod |
nph |
AntiDrift |
SR |
filter |
exp |
#frames |
disturb |
SN |
notes |
20130920_052815 |
??? |
13.1 |
76 |
3 |
1.12 0.81 |
221257 |
2 |
153 |
400 |
1.6 0.8 0.5 |
3 |
32 |
ON |
41.7 |
H |
1000 |
10 |
ONSKY |
zero.fits |
|
20130920_052829 |
??? |
13.0 |
76 |
4 |
NaN 0.65 |
221257 |
2 |
153 |
400 |
1.6 0.8 0.5 |
3 |
35 |
ON |
45.3 |
H |
1000 |
10 |
ONSKY |
zero.fits |
|
20130920_052843 |
??? |
13.0 |
76 |
3 |
NaN 0.61 |
221257 |
2 |
153 |
400 |
1.6 0.8 0.5 |
3 |
37 |
ON |
47.1 |
H |
1000 |
10 |
ONSKY |
zero.fits |
|
20130920_052934 |
??? |
13.0 |
76 |
4 |
NaN 0.52 |
221257 |
2 |
153 |
400 |
1.6 0.8 0.5 |
3 |
36 |
ON |
48.3 |
H |
1000 |
10 |
ONSKY |
zero.fits |
|
20130920_052948 |
??? |
13.0 |
76 |
3 |
NaN 0.47 |
221257 |
2 |
153 |
400 |
1.6 0.8 0.5 |
3 |
35 |
ON |
54.4 |
H |
1000 |
10 |
ONSKY |
zero.fits |
|
20130920_053001 |
??? |
13.6 |
76 |
3 |
NaN 0.56 |
221257 |
2 |
153 |
400 |
1.6 0.8 0.5 |
3 |
21 |
ON |
45.2 |
H |
1000 |
10 |
ONSKY |
zero.fits |
|
SR |
0.47007 (0.042724) |
SEEING (WFS) |
0.604661 (0.119783) |
SEEING (DIMM) |
1.11559 (NaN) |
Bin 3
05:45 preset AO750, gs=3, pa=0, Cat Mag=15.1 runao WFS Mag = 14.0
05:52 acq sky_irtc_psf
TrackNo |
RefStar |
Mag |
El |
Wind |
DIMM/OL |
Rec |
bin |
#mod |
freq |
gain |
mod |
nph |
AntiDrift |
SR |
filter |
exp |
#frames |
disturb |
SN |
notes |
20130920_055305 |
??? |
14.2 |
71 |
4 |
0.82 0.44 |
170946 |
3 |
66 |
312 |
2.1 0.6 -1.0 |
6 |
36 |
ON |
51.6 |
H |
1500 |
10 |
ONSKY |
zero.fits |
- Pupils not on target |
20130920_055324 |
??? |
14.2 |
71 |
4 |
0.81 0.39 |
170946 |
3 |
66 |
312 |
2.1 0.6 -1.0 |
6 |
36 |
ON |
52.5 |
H |
1500 |
10 |
ONSKY |
zero.fits |
|
20130920_055344 |
??? |
14.2 |
71 |
4 |
0.82 0.39 |
170946 |
3 |
66 |
312 |
2.1 0.6 -1.0 |
6 |
36 |
ON |
51.2 |
H |
1500 |
10 |
ONSKY |
zero.fits |
|
20130920_055447 |
??? |
14.2 |
71 |
3 |
0.82 0.44 |
170946 |
3 |
66 |
312 |
2.1 0.6 -1.0 |
6 |
37 |
ON |
49.4 |
H |
1500 |
10 |
ONSKY |
zero.fits |
- Pupils not on target |
20130920_055507 |
??? |
14.2 |
71 |
4 |
0.79 0.36 |
170946 |
3 |
66 |
312 |
2.1 0.6 -1.0 |
6 |
37 |
ON |
52.9 |
H |
1500 |
10 |
ONSKY |
zero.fits |
|
20130920_055526 |
??? |
14.2 |
71 |
3 |
0.79 0.40 |
170946 |
3 |
66 |
312 |
2.1 0.6 -1.0 |
6 |
37 |
ON |
51.7 |
H |
1500 |
10 |
ONSKY |
zero.fits |
|
SR |
0.51541 (0.0123732) |
SEEING (WFS) |
0.401677 (0.0300041) |
SEEING (DIMM) |
0.809668 (0.0145723) |
06:05 runao failed No star found on TV frame
Bin 4
06:06 preset AO751, runao. Cat Mag = 15.7, WFS Mag = 16.4
06:12 acq sky_irtc_psf
TrackNo |
RefStar |
Mag |
El |
Wind |
DIMM/OL |
Rec |
bin |
#mod |
freq |
gain |
mod |
nph |
AntiDrift |
SR |
filter |
exp |
#frames |
disturb |
SN |
notes |
20130920_061710 |
??? |
16.6 |
67 |
4 |
0.76 0.36 |
214654 |
4 |
36 |
100 |
1.6 0.9 0.9 |
6 |
22 |
ON |
* |
H |
1500 |
10 |
ONSKY |
zero.fits |
- Pupils not on target - SR may be in error |
20130920_061752 |
??? |
16.6 |
67 |
4 |
0.85 0.33 |
214654 |
4 |
36 |
100 |
0.0 -1.0 -1.0 |
6 |
22 |
ON |
* |
H |
1500 |
10 |
ONSKY |
zero.fits |
- SR may be in error |
20130920_061835 |
??? |
16.5 |
67 |
4 |
0.86 0.37 |
214654 |
4 |
36 |
100 |
0.0 -1.0 -1.0 |
6 |
23 |
ON |
* |
H |
1500 |
10 |
ONSKY |
zero.fits |
- Pupils not on target - Center of PSF estimation error |
SR |
0.666667 (0.57735) |
SEEING (WFS) |
0.353413 (0.0171778) |
SEEING (DIMM) |
0.825601 (0.0570215) |
06:20 preset, runao
06:27 Shell Ripped during Gain optimization routine
06:33 preset, runao
- Closed and auto gain success
- Offset -1.5, 3.6 Failed when resumeAO. Too much tilt? Safe Skip and then shell ripped.
06:43 Recover fail and Set
06:44 preset, runao .... Humidity goes to 95% Close Dome
Bin 4
08:15 Chamber open. preset AO824, Bin 4 WFS Mag 14.9
- Collected data set
- Offset 5 times with no problems
- Got a big tip and safe skip to ripped shell
Binary Star
TrackNo |
RefStar |
Mag |
El |
Wind |
DIMM/OL |
Rec |
bin |
#mod |
freq |
gain |
mod |
nph |
AntiDrift |
SR |
filter |
exp |
#frames |
disturb |
SN |
notes |
20130920_082258 |
??? |
15.2 |
71 |
4 |
1.01 1.33 |
214654 |
4 |
36 |
200 |
2.8 3.0 0.9 |
6 |
39 |
ON |
* |
H |
1500 |
10 |
ONSKY |
zero.fits |
- SR may be in error |
20130920_082320 |
??? |
15.1 |
71 |
4 |
1.13 1.21 |
214654 |
4 |
36 |
200 |
2.8 3.0 0.9 |
6 |
41 |
ON |
* |
H |
1500 |
10 |
ONSKY |
zero.fits |
- SR may be in error |
20130920_082342 |
??? |
15.1 |
71 |
4 |
1.02 0.95 |
214654 |
4 |
36 |
200 |
2.8 3.0 0.9 |
6 |
41 |
ON |
* |
H |
1500 |
10 |
ONSKY |
zero.fits |
- SR may be in error |
20130920_082447 |
??? |
15.1 |
71 |
4 |
1.00 0.84 |
214654 |
4 |
36 |
200 |
2.8 3.0 0.9 |
6 |
41 |
ON |
* |
H |
1500 |
10 |
ONSKY |
zero.fits |
- SR may be in error |
20130920_082509 |
??? |
15.1 |
71 |
3 |
0.90 0.75 |
214654 |
4 |
36 |
200 |
2.8 3.0 0.9 |
6 |
41 |
ON |
* |
H |
1500 |
10 |
ONSKY |
zero.fits |
- SR may be in error |
20130920_082531 |
??? |
15.1 |
71 |
3 |
0.93 0.81 |
214654 |
4 |
36 |
200 |
2.8 3.0 0.9 |
6 |
41 |
ON |
* |
H |
1500 |
10 |
ONSKY |
zero.fits |
- SR may be in error |
SR |
0.0855602 (0.0133905) |
SEEING (WFS) |
0.983134 (0.233531) |
SEEING (DIMM) |
0.999969 (0.0809216) |
08:23 Recover Fail. Success
08:27 Set. Failed. Had Safe Skip and then rip and recover fail
08:31 Set. Successful
Bin 3
08:37 preset AO130, Cat Mag = 14.1 bin 3. Failed no guide star. Geno set pointing
08:44 preset AO130
08:50 acq sky_irtc_psf
TrackNo |
RefStar |
Mag |
El |
Wind |
DIMM/OL |
Rec |
bin |
#mod |
freq |
gain |
mod |
nph |
AntiDrift |
SR |
filter |
exp |
#frames |
disturb |
SN |
notes |
20130920_084940 |
??? |
13.5 |
68 |
3 |
0.86 0.40 |
221257 |
2 |
153 |
400 |
1.6 0.5 0.5 |
3 |
24 |
ON |
51.1 |
H |
1500 |
10 |
ONSKY |
zero.fits |
- SR may be in error |
20130920_085000 |
??? |
13.4 |
68 |
3 |
0.87 0.39 |
221257 |
2 |
153 |
400 |
1.6 0.5 0.5 |
3 |
24 |
ON |
49.4 |
H |
1500 |
10 |
ONSKY |
zero.fits |
|
20130920_084921 |
??? |
13.5 |
68 |
3 |
0.88 0.43 |
221257 |
2 |
153 |
400 |
1.6 0.5 0.5 |
3 |
24 |
ON |
50.2 |
H |
1500 |
10 |
ONSKY |
zero.fits |
|
20130920_085139 |
??? |
13.5 |
68 |
3 |
0.95 0.66 |
221257 |
2 |
153 |
400 |
1.6 0.5 0.5 |
3 |
23 |
ON |
38.8 |
H |
1500 |
10 |
ONSKY |
zero.fits |
|
20130920_085121 |
??? |
13.5 |
68 |
3 |
0.96 0.67 |
221257 |
2 |
153 |
400 |
1.6 0.5 0.5 |
3 |
23 |
ON |
34.0 |
H |
1500 |
10 |
ONSKY |
zero.fits |
|
20130920_085103 |
??? |
13.5 |
68 |
3 |
1.18 0.54 |
221257 |
2 |
153 |
400 |
1.6 0.5 0.5 |
3 |
23 |
ON |
37.3 |
H |
1500 |
10 |
ONSKY |
zero.fits |
|
SR |
0.43462 (0.0757836) |
SEEING (WFS) |
0.517156 (0.128701) |
SEEING (DIMM) |
0.951349 (0.119611) |
Bin 2
08:55 preset AO199, Cat Mag = 12.4, WFS Mag = 11.6
09:05 acq sky_irtc_psf
Star not on IRTC
TrackNo |
RefStar |
Mag |
El |
Wind |
DIMM/OL |
Rec |
bin |
#mod |
freq |
gain |
mod |
nph |
AntiDrift |
SR |
filter |
exp |
#frames |
disturb |
SN |
notes |
20130920_090550 |
??? |
11.7 |
46 |
3 |
1.00 0.71 |
221257 |
2 |
153 |
991 |
2.1 0.6 0.5 |
3 |
50 |
ON |
* |
H |
1500 |
10 |
ONSKY |
zero.fits |
- SR may be in error |
20130920_090609 |
??? |
11.7 |
46 |
3 |
1.00 0.67 |
221257 |
2 |
153 |
991 |
2.1 0.6 0.5 |
3 |
49 |
ON |
* |
H |
1500 |
10 |
ONSKY |
zero.fits |
- Could not test SR quality |
20130920_090629 |
??? |
11.7 |
46 |
3 |
1.00 0.62 |
221257 |
2 |
153 |
991 |
2.1 0.6 0.5 |
3 |
50 |
ON |
* |
H |
1500 |
10 |
ONSKY |
zero.fits |
- SR may be in error |
20130920_090730 |
??? |
11.7 |
46 |
4 |
0.92 0.66 |
221257 |
2 |
153 |
991 |
2.1 0.6 0.5 |
3 |
49 |
ON |
* |
H |
1500 |
10 |
ONSKY |
zero.fits |
- SR may be in error |
20130920_090748 |
??? |
11.7 |
46 |
3 |
0.89 0.74 |
221257 |
2 |
153 |
991 |
2.1 0.6 0.5 |
3 |
50 |
ON |
* |
H |
1500 |
10 |
ONSKY |
zero.fits |
- Center of PSF estimation failed |
20130920_090807 |
??? |
11.7 |
46 |
3 |
1.01 0.88 |
221257 |
2 |
153 |
991 |
2.1 0.6 0.5 |
3 |
49 |
ON |
* |
H |
1500 |
10 |
ONSKY |
zero.fits |
- SR may be in error |
SR |
0.833333 (0.408248) |
SEEING (WFS) |
0.712773 (0.0895572) |
SEEING (DIMM) |
0.971539 (0.0513105) |
09:15 Closed Dome for Humidity
--
DougMiller - 20 Sep 2013