Forecast.

Screen Shot 2024-04-28 at 5.08.26 PM.png

Screen Shot 2024-04-28 at 5.08.47 PM.png

Details.

05:00

Power on SX

AO log google doc.

https://docs.google.com/document/d/1odjBeVtaoMnGm0nplu2MI0RblwdK6Tw-Cxjf5FMEJ30/edit?usp=sharing

07:00 PM

Open

Bino Luci.

Pointing/ collimation checkout.

07:52PM

seeing around 1"

preset

03:14:34.958 2024 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[2721] (aomode:TTM-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:-5.98364[-5.98364],soy:-5.98364,rox:-67.5008[-67.5008],roy:4.93465,mag:15.08,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

Manual optimize 1.4, 0.3,0.05

Seeing 1.2

alignment target in the slit

Science start: 08:37

09:47

seeing ~1.5"


Mon Apr 29 05:29:30.230 2024 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[2802] (aomode:TTM-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:-5.98364[-5.98364],soy:-5.98364,rox:-67.3579[-67.3579],roy:5.02,mag:15.08,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

New preset. Star checked.

Mon Apr 29 05:29:30.230 2024 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[2802] (aomode:TTM-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:-5.98364[-5.98364],soy:-5.98364,rox:-67.3579[-67.3579],roy:5.02,mag:15.08,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

Gains:1.3,0.8

Seeing 1.8”

TN:_053315

FWHM 7 pixels. Not good.

Change to noAO

04:30 call the night.

-- JuanCarlosGuerra - 29 Apr 2024
Topic revision: r4 - 29 Apr 2024, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.