Forecast.

Screen Shot 2024-03-20 at 6.33.45 PM.png

Screen Shot 2024-03-20 at 6.34.05 PM.png

Details.

Power on SX and DX for any possible AO.

SX.
  • ocam bad quadrant.
  • power cycle bcu2k
  • rebin OK
DX
  • ocam not live.
  • masterdiagn up/down
  • OK.
  • Ocam shows two bad quadrants.
  • power cycle bcu2k
  • rebin
  • OK.
  • Ocam not live
  • master diagn restart
  • OK.

Ocam cool down 6PM

06:37PM

Clouds passing .

Observer called for sharks.

his is to confirm that SHARK-VIS will try to observe tonight. We are taking control of the telescope now, at the beginning of the night. Let's see how it goes and then in case conditions get worse we will give back the telescope to INAF. SHARK-NIR will be in parallel.

The program is the following (with the SV configs):

- IC 2149 (planetary nebula) (config 3: SV_Halpha_LP)

- 451 Patientia (asteroid) (config 2: SV_Lmirc_NO)

- HD 93531 (all 4 configs in series)



10: SVHalphaLP (*) -43.660 -35.720
lrwxrwxrwx. 1 dxwunit dxwunit 25 Mar 21 01:57 SHARK_ACE-AO -> SHARK_ACE-AO.HalphaLP.txt

lrwxrwxrwx. 1 dxwunit dxwunit 16 Mar 21 01:56 SHARK -> SV_Halpha_direct

07:00

Opening

pointing and collmation. Beta Auriga.

Justing doing the SX and Juan CArlos doing DX.

07:18

seeing 1.6"

cosed loop optimized

All good

TN:20240320_022038

u Mar 21 02:21:00.692 2024 aos.Stop{FLAO}.complete - Stop{FLAO}[454]
Thu Mar 21 02:21:05.166 2024 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[455] (aomode:ACE-AO,focst:bentGregorianCenter,instr:SHARK,wfs:LBTIWFS,sox:0[0],soy:0,rox:-0.040168[-0.040168],roy:2.54953e-08,mag:1.82,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

IE=53, CA=153

adsec DX failure during center pupil.

I think that it was due to a position about 1 to 2 arcseconds off, the star

close loop agan.

TN:_030857

08:14

seeing 1.4-1.6

TN:_031626

seeing variable.

SX tn:_032021,032154,032319

DX:032132,032156,_032314

adsecsx is skipping frames, TT lower than DX.

SX open loop due to skipping frames.

08:33

seeing 1.22"

08:35

Some sharkvs issues with the connection to the camera.

08:38

Pause loop

Shark needs a restart.

TN:_033952

08:43

resume

SX:_034354

DX:_034358,_035820

SX:_035731,_035819

09:35 PM

preset send from the

Preset sent by Justin, override and DX only sent the SYNCPreset.

Screen Shot 2024-03-20 at 9.50.24 PM.png

Close loop 451 Patientia.

Optimize at 88 and again at 88.

transit SX open loop, DX jhold it.

DX:_044737,_044835

SX:_044851,_044903

Shrvis pupil. !! Nice !!

Screen Shot 2024-03-20 at 9.55.25 PM.png

SX:_045809,

DX:

close loop at high elevation doen;t keep good performances, range 87 to 89 and back to 87.

10PM

Handover to INAF.

power off soul-lucis WFS.

Change to MODS no LuciAO for tonight.

-- JuanCarlosGuerra - 21 Mar 2024