Detals.

Power on

Ocam

OK.

TEst preset.

Mon Mar 18 19:41:17.199 2024 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[759] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

OK.

Mon Mar 18 19:47:37.004 2024 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[760] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Mar 18 19:47:37.021 2024 aos.info - WFS source set to: FLAOWFS
Mon Mar 18 19:47:37.069 2024 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.6_L040.0_v15.0_ovfreq1700.00_sd3892.fits

the focus was set to 52.9

changed to 51.5

OK.

Preset.

bad frame: trinagel shape.

power cycle bcu2k

off: 201557

on:_202109

ok

270.

Mon Mar 18 20:23:14.038 2024 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[770] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Mar 18 20:23:14.062 2024 aos.info - WFS source set to: FLAOWFS
Mon Mar 18 20:23:14.106 2024 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.6_L040.0_v15.0_ovfreq1700.00_sd3892.fits

off:202856

on:_202924

210.

Mon Mar 18 20:32:00.338 2024 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[774] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Mar 18 20:32:00.355 2024 aos.info - WFS source set to: FLAOWFS
Mon Mar 18 20:32:00.397 2024 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.6_L040.0_v15.0_ovfreq1700.00_sd3892.fits

off: _203638

ON:_203700

150.

Mon Mar 18 20:38:53.077 2024 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[778] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Mar 18 20:38:53.091 2024 aos.info - WFS source set to: FLAOWFS
Mon Mar 18 20:38:53.128 2024 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.6_L040.0_v15.0_ovfreq1700.00_sd3892.fits

off:204259

ON:204521

90

Mon Mar 18 20:38:53.077 2024 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[778] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Mar 18 20:38:53.091 2024 aos.info - WFS source set to: FLAOWFS
Mon Mar 18 20:38:53.128 2024 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.6_L040.0_v15.0_ovfreq1700.00_sd3892.fits

off:205435

on:205458

30

Mon Mar 18 20:38:53.077 2024 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[778] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Mar 18 20:38:53.091 2024 aos.info - WFS source set to: FLAOWFS
Mon Mar 18 20:38:53.128 2024 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.6_L040.0_v15.0_ovfreq1700.00_sd3892.fits

off

on

REstore last night files for focus and ncpa.

z=52.9

optimize:211434

lrwxrwxrwx. 1 AOeng AOeng 21 Feb 11 08:40 LUCIFER~ -> ncpa_fit_20231214.dat
lrwxrwxrwx. 1 AOeng AOeng 26 Mar 18 21:08 LUCIFER -> ncpa_measured_20231225.dat

off:211804

on:211900

back to good values.

Mon Mar 18 21:23:02.910 2024 aos.info - Updated variable AOARB.L.AO_READY: 1
Mon Mar 18 21:23:02.910 2024 aos.PresetAO{FLAO}.complete - PresetAO{FLAO}[795] - dx:nan dy:nan slNull: f1:0.0 f2:1.0 freq:1700 mag:0 nBins:1 nModes:501 r0:nan snMode:0 strehl:0 ttMod:0
Mon Mar 18 21:25:06.287 2024 aos.AcquireRef{FLAO}.started - AcquireRef{FLAO}[796] Mode: Move stages, Automatic acquire

foc z=51.5

ncpa: ncpa_fit_20231214.dat

off:213124,_213714

on:_213251,_213733

Done at 02:40PM

-- JuanCarlosGuerra - 18 Mar 2024
Topic revision: r1 - 18 Mar 2024, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback