Staff:

LBTO: Steve, Justin, Jenny, Juan CArlos

Observer. Nan

Forecast.

Screen Shot 2024-03-17 at 5.09.01 PM.png

Screen Shot 2024-03-17 at 5.09.37 PM.png

Details.

loaded SW version:

Currently running: test.20240223.zero-slope-firmware-and-repoint (soul)

Observer log: https://docs.google.com/document/d/1aB_xJmkRmQgR0E51kG7RA8VtbFnBuoz-oYiO3bVoAMI/edit?usp=sharing_eil_se_dm&ts=65f788c8

05:10PM Power on DX/SX

Ocam SX

OK

Ocam DX
  • bad quadrant.
  • power cycle ocam2K
  • rebin
  • ok
Screen Shot 2024-03-17 at 5.20.41 PM.png

PSF morphology.

Screen Shot 2024-03-17 at 5.31.45 PM.png

Screen Shot 2024-03-17 at 5.32.18 PM.png

"Gaia DR3 761109612631296640"/>









"LUCIAORef"/>









  • It can be done a binocular.
  • NCPA ON.

06:24PM

Clouds passing.

Not opening at sunset.

07:49PM

Opening.

08:00PM

Repointing test.

08:50

seeing 1.5"

Mon Mar 18 04:22:22.583 2024 aos.AcquireRef{FLAO}.started - AcquireRef{FLAO}[50] Mode: Repoint telescope, Automatic acquire
Mon Mar 18 04:22:22.607 2024 aos.info - Computing telescope offset for AcquireRefAO
Mon Mar 18 04:22:27.739 2024 aos.info - Updated variable AOARB.R.RR_ENABLED: 0
Mon Mar 18 04:22:27.740 2024 aos.info - Offset required - dx,dy: (0.174,0.397). [(0.0506833,0.0328283) -> (0.224683,0.429828)]
Mon Mar 18 04:22:27.755 2024 aos.info - Updated variable AOARB.R.LAB_MODE: 0
Mon Mar 18 04:22:27.772 2024 aos.info - AOS tel- repoint_request Collection connected to Telemetry Store

another preset.

Mon Mar 18 04:28:43.707 2024 aos.AcquireRef{FLAO}.started - AcquireRef{FLAO}[53] Mode: Repoint telescope, Automatic acquire
Mon Mar 18 04:28:43.727 2024 aos.info - Computing telescope offset for AcquireRefAO
Mon Mar 18 04:28:48.728 2024 aos.info - Updated variable AOARB.R.RR_ENABLED: 0
Mon Mar 18 04:28:48.728 2024 aos.info - Offset required - dx,dy: (0.382,0.439). [(0.0399971,0.031836) -> (0.421997,0.470836)]

Presety withy Guider OFF

Mon Mar 18 04:31:19.539 2024 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[55] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0.0359095[0.0359095],roy:0.0315168,mag:8.78,cindex:2.82,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Mar 18 04:31:19.556 2024 aos.info - WFS source set to: FLAOWFS

start dow the cross heiar.


Mon Mar 18 04:32:43.820 2024 aos.info - Updated variable AOARB.R.RR_ENABLED: 0
Mon Mar 18 04:32:43.821 2024 aos.info - Offset required - dx,dy: (-0.745,1.038). [(0.0359095,0.0315168) -> (-0.709091,1.06952)]

center star.

x=-74.8, y=-50.237

thorugh IIF.

on Mar 18 04:38:26.728 2024 aos.PresetAO{FLAO}.complete - PresetAO{FLAO}[58] - dx:nan dy:nan slNull: f1:0.0 f2:1.0 freq:1700 mag:0 nBins:1 nModes:630 r0:nan snMode:0 strehl:0 ttMod:0
Mon Mar 18 04:38:47.358 2024 aos.AcquireRef{FLAO}.started - AcquireRef{FLAO}[59] Mode: Repoint telescope, Automatic acquire
Mon Mar 18 04:38:47.375 2024 aos.info - Computing telescope offset for AcquireRefAO
Mon Mar 18 04:38:52.834 2024 aos.info - Updated variable AOARB.R.RR_ENABLED: 0
Mon Mar 18 04:38:52.834 2024 aos.info - Offset required - dx,dy: (0.187,0.311). [(0.0285062,0.0310293) -> (0.215506,0.342029)]

AOSGUI.

Mon Mar 18 04:43:06.626 2024 aos.AcquireRef{FLAO}.started - AcquireRef{FLAO}[63] Mode: Repoint telescope, Automatic acquire
Mon Mar 18 04:43:06.645 2024 aos.info - Computing telescope offset for AcquireRefAO
Mon Mar 18 04:43:12.005 2024 aos.info - Updated variable AOARB.R.RR_ENABLED: 0
Mon Mar 18 04:43:12.006 2024 aos.info - Offset required - dx,dy: (0.191,0.279). [(0.0237807,0.0307818) -> (0.214781,0.309782)]

...

change to SX.

IIF try out.

the AOSGUI activate the repoint button.

Mon Mar 18 04:51:02.540 2024 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[418] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0.0135774[0.0135774],roy:0.0304056,mag:8.78,cindex:2.82,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Mar 18 04:51:02.552 2024 aos.info - WFS source set to: FLAOWFS
Mon Mar 18 04:51:03.276 2024 aos.info - FLAO: WFS: loading setup for LUCIFER
Mon Mar 18 04:51:03.307 2024 aos.info - FLAO: WFS: configuring CCDs

preset withy the repont activate.

same positions as before.

Mon Mar 18 04:51:25.406 2024 aos.PresetAO{FLAO}.complete - PresetAO{FLAO}[418] - dx:nan dy:nan slNull: f1:0.0 f2:1.0 freq:1700 mag:0 nBins:1 nModes:501 r0:nan snMode:0 strehl:0 ttMod:0
Mon Mar 18 04:52:17.200 2024 aos.AcquireRef{FLAO}.started - AcquireRef{FLAO}[419] Mode: Repoint telescope, Automatic acquire
Mon Mar 18 04:52:17.224 2024 aos.info - Computing telescope offset for AcquireRefAO
Mon Mar 18 04:52:22.655 2024 aos.info - Updated variable AOARB.L.RR_ENABLED: 0
Mon Mar 18 04:52:22.655 2024 aos.info - Offset required - dx,dy: (-0.573,-1.496). [(0.0135774,0.0304056) -> (-0.559423,-1.46559)]

09:30

PSF morphology

issue with the luci1. the camer stays in n1.8 and it supposed to be in n30

Dave call

Mon Mar 18 05:19:44.947 2024 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[75] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0.0881966[0.0881966],roy:0.00802532,mag:11.46,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

Mon Mar 18 05:19:40.572 2024 aos.Stop{FLAO}.complete - Stop{FLAO}[429]
Mon Mar 18 05:19:44.827 2024 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[430] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0.0881976[0.0881976],roy:0.00802549,mag:11.46,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Mar 18 05:19:44.878 2024 aos.info - WFS source set to: FLAOWFS

rght .


Mon Mar 18 05:33:19.762 2024 aos.info - FLAO Alert [ code:177] SkipFrame
Mon Mar 18 05:33:20.073 2024 aos.Pause{FLAO}.started - Pause{FLAO}[71]
Mon Mar 18 05:33:20.113 2024 aos.Pause{FLAO}.failed - Pause{FLAO}[71] - Illegal command for state LoopFault

Dx showed problems due to a bad quadrant.

adsec in failure.

|2024-03-18 06:04:50.720952| MAIN > Enabling DSP WATCHDOG...
idl_74066 |INF| 430|2024-03-18 06:04:50.723699| MAIN > ... done.
idl_74066 |INF| 431|2024-03-18 06:04:50.900844| MAIN > Oversampling frames disabled.
idl_74066 |INF| 432|2024-03-18 06:04:50.900880| MAIN > Reference wave decreased
idl_74066 |INF| 433|2024-03-18 06:04:50.906947| MAIN > Oversampling frames disabled.
idl_74066 |INF| 434|2024-03-18 06:04:50.906970| MAIN > Disabling DSP WATCHDOG...
idl_74066 |INF| 435|2024-03-18 06:04:50.910209| MAIN > ... done.
idl_74066 |INF| 436|2024-03-18 06:04:50.910683| MAIN > Uploading reference wave paramenters...
idl_74066 |INF| 437|2024-03-18 06:04:51.037517| MAIN > ... done.
idl_74066 |INF| 438|2024-03-18 06:04:51.037586| MAIN > Enabling DSP WATCHDOG...
idl_74066 |INF| 439|2024-03-18 06:04:51.040472| MAIN > ... done.
idl_74066 |INF| 440|2024-03-18 06:04:51.218662| MAIN > Oversampling frames disabled.
idl_74066 |ERR| 441|2024-03-18 06:04:53.420669| MAIN > [AOException] Error (Timeout error) in GetDiagnValue [2] (code -5001) Timeout error
20241803 06:04:53.4218 Alert: Warning: loadProgram failed or syntax error occured

fastdiagn down.

Stop the prset, it could be that we are too high ???

Stop the PSF morphology. doing ESM instead.

11:12 ESM.

seems an issue with the preset stack.

shells rest.

Restart AOS.

OK.

Mon Mar 18 06:17:53.005 2024 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[114] (aomode:TTM-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:-58.7159[-58.7159],roy:-15.9606,mag:16.6,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

Mon Mar 18 06:17:53.005 2024 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[114] (aomode:TTM-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:-58.7159[-58.7159],roy:-15.9606,mag:16.6,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

SX shows to have a larger frequency at 30Hz.

TN:_062837._062944

DX:_063132

done with it.

12:28 PSF morphology

Mon Mar 18 07:28:52.353 2024 aos.info - TTF offload command end
Mon Mar 18 07:29:01.197 2024 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[562] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:-0.0541672[-0.0541672],roy:0.00295399,mag:11.46,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

Mon Mar 18 07:29:01.158 2024 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[206] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:-0.054167[-0.054167],roy:0.00295398,mag:11.46,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

gopt failed in DX. during the automatic mode.

Send again the preset.

to be improved at least the retry.

1:53

Restartijg the scrpt and finished the PSF morphology script.

Done with the 01:54

Change to ESM.

02:01

SX went offline.

resart software.OK.

Preset to bin1 but the star is about 15 mag and the bin1 is not correct for the star.

Jenny looking at a dfferent target or to build new scripts.

03:00

Getting cloudy. Jenny will take care of the next ESM.

IT.

soul-luciDX bad quadrant.

#9072

Screen Shot 2024-03-17 at 9.44.04 PM.png

Juan Carlos done for tonight.

-- JuanCarlosGuerra - 18 Mar 2024
Topic revision: r3 - 18 Mar 2024, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.