Summary.

  • Run the bin4 with the origianl pupil but sing the file readySlopes.txt from the shift back/forward.
  • The test done showed that the resonance peak shows around 100Hz and the pupils looks stable, a modal SR of about 45% wth disturbnce injected of 0.8arcsec.
  • A second test was the Repoint (Xianyu). The test of repoint looks good from Xianyu checks. The only thing to consider is that the optio Repoint from the AOS GUI should not be used during daytime. The reason is that the PCS wait to do something and the Acquire Ref (AOS) wait toi have some feedback from PCS, so AOS get hung.

Details.

cp the shifted file generated after the movePupil script into the original directory.

Original pupil: 20200916_173857

diff readySlopes.txt.original readySlopes.txt

Power on DX.

Ocam

Prest preset.

Fri Mar 15 16:27:40.510 2024 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[634] (aomode:ACE-AO,focst:bentGregorianCenter,instr:LBTI,wfs:LBTIWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.6,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Mar 15 16:27:40.527 2024 aos.info - WFS source set to: LBTIWFS
Fri Mar 15 16:27:40.660 2024 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq500.00_sd3892.fits

Xianyu connected to ask to perform a test with the repoint SW version.

Currently running: test.20240223.zero-slope-firmware-and-repoint (soul)

w_stop/start_all

Fri Mar 15 16:51:49.389 2024 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[635] (aomode:ACE-AO,focst:bentGregorianCenter,instr:LBTI,wfs:LBTIWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.6,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Mar 15 16:51:49.404 2024 aos.info - WFS source set to: LBTIWFS
Fri Mar 15 16:51:49.449 2024 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq500.00_sd3892.fits

cancel preset.

Click repoint.

Fri Mar 15 16:52:52.460 2024 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[636] (aomode:ACE-AO,focst:bentGregorianCenter,instr:LBTI,wfs:LBTIWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.6,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Mar 15 16:52:52.475 2024 aos.info - WFS source set to: LBTIWFS
Fri Mar 15 16:52:52.516 2024 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq500.00_sd3892.fits

cancel preset.
  • Click repoint.
  • Preset.
  • button deactivated during the preset.
  • Activate repoint
  • Acquire
  • The repoint button remain activated.
Xianyu checking the TCS side.

Acquire ref failed.

cancel preset

repoint remain active during the next preset.

for daytiem the acqure process remain Running event after the preset was cancel.

Clear the state:

Rest adsec from Adsec control gui.

Restart AOarb

restart AOS gui

OK.

preset mag 10

OK.

cancel preset.

shuter 90

mag 15.5

Preset Bin4.

Fri Mar 15 17:31:02.102 2024 aos.AcquireRef{FLAO}.complete - AcquireRef {FLAO}[5] - dx:0 dy:0 slNull: f1:1.0 f2:1.0 freq:452 mag:0 nBins:4 nModes:54 r0:nan snMode:0 strehl:0 ttMod:0
Fri Mar 15 17:31:52.509 2024 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[6] (aomode:ACE-AO,focst:bentGregorianCenter,instr:LBTI,wfs:LBTIWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.6,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Mar 15 17:31:52.524 2024 aos.info - WFS source set to: LBTIWFS
Fri Mar 15 17:31:52.564 2024 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq500.00_sd3892.fits

better puils.

manual gain:

TN:20240315_173610

optimize gain:0.79,0.87,0.1

TN:_174001

make a pupil shift.

> >> from AdOpt import makePupils
WARNING: AstropyDeprecationWarning: Python 2.6 will no longer be supported from Astropy v1.2.0 and above [astropy]
>>> makePupils.movePupils('20200916_173857',-1,0,240,5)
makePupils_fromMasks(): moving from /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt to /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240315_175600/pupdata.txt
/bin/mv -f "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt" "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240315_175600/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 80
out_of_pupil_slopes 2688
lines_to_add 12
residual_pixels_to_add 12
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5 to /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240315_175600
/bin/mv -f "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pup1.fits" "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240315_175600"
'20240315_175600'
>>> makePupilsmovePupils('20240315_175600',1,0,240,5)
Traceback (most recent call last):
File "", line 1, in
NameError: name 'makePupilsmovePupils' is not defined
>>> makePupils.movePupils('20240315_175600',1,0,240,5)
makePupils_fromMasks(): moving from /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt to /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240315_175718/pupdata.txt
/bin/mv -f "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt" "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240315_175718/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 80
out_of_pupil_slopes 2688
lines_to_add 12
residual_pixels_to_add 12
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5 to /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240315_175718
/bin/mv -f "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pup1.fits" "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240315_175718"
'20240315_175718'


cp the readySlopes.txt from 20240315_175718'

change bin

Fri Mar 15 18:43:10.182 2024 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[10] (aomode:ACE-AO,focst:bentGregorianCenter,instr:LBTI,wfs:LBTIWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.6,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Mar 15 18:43:10.194 2024 aos.info - WFS source set to: LBTIWFS
Fri Mar 15 18:43:10.270 2024 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq500.00_sd3892.fits

optimize gain, pupil stable gains higher.

TN:_184657

gan1.98

rise tt 5.6

Resonant frequency to be visible at 100Hz.

Screen Shot 2024-03-15 at 1.20.03 PM.png

TN:_185247

gopt on.

TN:_185736,_185818

slope SR ~45%

Stop12:05

Argos parked.Adsec rest.

handover to Mountain crew

-- JuanCarlosGuerra - 15 Mar 2024
Topic revision: r3 - 15 Mar 2024, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.