Detail.

pupil Bin4.

20230221_093800

test preset.

Tue Mar 12 21:34:38.054 2024 aos.info - FLAO: WFS: setup done.
Tue Mar 12 21:37:15.101 2024 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[577] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.6,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

ocam not live.

Reconfigure reports the error with the opt loop buffere.

restart masterdiagn process

OK.

Mar 12 21:39:03.972 2024 aos.info - Updated variable AOARB.R.AO_READY: 1
Tue Mar 12 21:39:03.973 2024 aos.PresetAO{FLAO}.complete - PresetAO {FLAO}[577] - dx:nan dy:nan slNull: f1:0.0 f2:1.0 freq:282 mag:0 nBins:4 nModes:55 r0:nan snMode:0 strehl:0 ttMod:0
Tue Mar 12 21:42:35.774 2024 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[578] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.6,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Mar 12 21:42:35.794 2024 aos.info - WFS source set to: FLAOWFS
Tue Mar 12 21:42:35.826 2024 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq500.00_sd3892.fits

TN:215339

rise TT to 7.8

resonance about 70Hz.

TN:_215852,_215952

no disturbance.

TN:221212

500Hz no disturbance.

LBTIDX pupil generation for bin4.

> >> mp.movePupils('20200916_173857',-1,0,240,5)
makePupils_fromMasks(): moving from /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt to /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240312_231506/pupdata.txt
/bin/mv -f "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt" "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240312_231506/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 80
out_of_pupil_slopes 2688
lines_to_add 12
residual_pixels_to_add 12
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5 to /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240312_231506
/bin/mv -f "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pup1.fits" "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240312_231506"
'20240312_231506'
>>> mp.movePupils('20240312_231506',1,0,240,5)
makePupils_fromMasks(): moving from /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt to /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240312_231528/pupdata.txt
/bin/mv -f "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt" "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240312_231528/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 80
out_of_pupil_slopes 2688
lines_to_add 12
residual_pixels_to_add 12
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5 to /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240312_231528
/bin/mv -f "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pup1.fits" "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240312_231528"
'20240312_231528'
>>>


-- JuanCarlosGuerra - 12 Mar 2024