Details.

Run lbtiSX+DX.

SW: Currently running: test.20240223.zero-slope-firmware-and-repoint (soul)

DX: Currently running: test.20240223.zero-slope-firmware-and-repoint (soul)

close loop mag 16.6

shutter 48

mag 16.5 approx.

skip check flux.

disturbance 1.6 for 500Hz.

optimize:20240307_182420,

optical loop

20240307_182652,_182708,_182722

Close loop in Bn4 leave running.

Screen Shot 2024-03-07 at 11.25.47 AM.png

Close loop on DX.

Preset DX.

Thu Mar 7 18:33:15.218 2024 aos.PresetAO{FLAO}.complete - PresetAO {FLAO}[417] - dx:nan dy:nan slNull: f1:1.0 f2:1.0 freq:452 mag:0 nBins:4 nModes:54 r0:nan snMode:0 strehl:0 ttMod:0
Thu Mar 7 18:33:26.803 2024 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[418] (aomode:ACE-AO,focst:bentGregorianCenter,instr:LBTI,wfs:LBTIWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.6,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Mar 7 18:33:26.820 2024 aos.info - WFS source set to: LBTIWFS
Thu Mar 7 18:33:26.859 2024 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq500.00_sd3892.fits

shutter 81, mag 16.6

optimize:20240307_184127

DX stopped, seemsn not correcting gains too low.

saved TN:20240307_184658

and bcudump

TT jitter aux plot shows almost not correcitons.

Screen Shot 2024-03-07 at 11.48.27 AM.png

both adsecs showed same behaviour.

SX.TN: _185224, it almost not corrections.

Open loop both

masterdiag SX.

MasterDiagnostic _6094|INF| 61|2024-03-07 18:22:27.494004| MAIN > Setting optical loop CLOSED
MasterDiagnostic_6094|INF| 62|2024-03-07 18:22:27.494101| MAIN > Optical loop set to 1 ...
MasterDiagnostic_6094|ERR| 63|2024-03-07 18:24:20.150433| OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 00000000 and 17256BE9
MasterDiagnostic_6094|INF| 64|2024-03-07 18:45:25.365831| MAIN > Setting optical loop OPEN

master DX.

MasterDiagnostic _21188|WAR| 713|2024-03-07 18:47:20.942775| BCU39 > FramesDownloader BCU39: [InvalidDiagnosticPacketException] Unexpected packetId 1 for frameId 393 (instead of packetId 0 for frameId 393)
MasterDiagnostic_21188|WAR| 714|2024-03-07 18:47:20.942786| BCU39 > FramesDownloader BCU39: packet successfully ignored !
MasterDiagnostic_21188|WAR| 715|2024-03-07 18:47:20.942816| BCU39 > FramesDownloader BCU39: [InvalidDiagnosticPacketException] Unexpected packetId 2 for frameId 393 (instead of packetId 0 for frameId 393)
MasterDiagnostic_21188|WAR| 716|2024-03-07 18:47:20.942826| BCU39 > FramesDownloader BCU39: packet successfully ignored !
MasterDiagnostic_21188|WAR| 717|2024-03-07 18:48:02.677377| BCU39 > FramesDownloader BCU39: [InvalidDiagnosticPacketException] Unexpected packetId 0 for frameId 15 (instead of packetId 1 for frameId 13)
MasterDiagnostic_21188|WAR| 718|2024-03-07 18:48:02.677421| BCU39 > FramesDownloader BCU39: packet successfully ignored !
MasterDiagnostic_21188|WAR| 719|2024-03-07 18:48:02.677463| BCU39 > FramesDownloader BCU39: [InvalidDiagnosticPacketException] Unexpected packetId 1 for frameId 15 (instead of packetId 0 for frameId 15)
MasterDiagnostic_21188|WAR| 720|2024-03-07 18:48:02.677478| BCU39 > FramesDownloader BCU39: packet successfully ignored !
MasterDiagnostic_21188|INF| 721|2024-03-07 18:49:03.133507| MAIN > Setting optical loop OPEN

Reset both BCUs changing binnings

SX.

Thu Mar 7 19:00:10.090 2024 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[204] (aomode:ACE-AO,focst:bentGregorianCenter,instr:LBTI,wfs:LBTIWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.6,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Mar 7 19:00:10.107 2024 aos.info - WFS source set to: LBTIWFS
Thu Mar 7 19:00:10.139 2024 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq500.0000_sd3892.fits

DX.

Thu Mar 7 19:00:10.090 2024 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[204] (aomode:ACE-AO,focst:bentGregorianCenter,instr:LBTI,wfs:LBTIWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.6,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Mar 7 19:00:10.107 2024 aos.info - WFS source set to: LBTIWFS
Thu Mar 7 19:00:10.139 2024 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq500.0000_sd3892.fits

optmize:20240307_190620, 0.99,0.68,0.1

TN:191918,

rise TT. Shell rip too much

restart adsec.

SX.

close loop

mag 15

optimize:_192201

pupil:20230405_091420

4.55,1.22,0.1

Screen Shot 2024-03-07 at 12.23.47 PM.png

Screen Shot 2024-03-07 at 12.23.55 PM.png

rise TT to 7

TN:_192809

TT 8

TN:_192917

Screen Shot 2024-03-07 at 12.29.12 PM.png

SX running.

preset DX.

Thu Mar 7 19:19:45.888 2024 aos.info - Updated variable AOARB.R.RR_ENABLED: 1
Thu Mar 7 19:36:44.304 2024 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[426] (aomode:ACE-AO,focst:bentGregorianCenter,instr:LBTI,wfs:LBTIWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.6,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Mar 7 19:36:44.324 2024 aos.info - WFS source set to: LBTIWFS
Thu Mar 7 19:36:44.365 2024 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq500.00_sd3892.fits

shutter 90

mag 15.2

pupil:20200916_173857

optimize:_194210,

1,03,0.87,0.10

rise tt 1.8

oscilalting ~50

TN:194655

Screen Shot 2024-03-07 at 12.46.28 PM.png


Apply procedure for shift DX pupil bin4.

> >> makePupils.movePupils('20200916_173857',0,1,240,5)
makePupils_fromMasks(): moving from /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt to /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240307_195743/pupdata.txt
/bin/mv -f "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt" "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240307_195743/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 80
out_of_pupil_slopes 2688
lines_to_add 12
residual_pixels_to_add 12
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5 to /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240307_195743
/bin/mv -f "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pup1.fits" "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240307_195743"
'20240307_195743

> >> makePupils.movePupils('20240307_195743',0,-1,240,5)
makePupils_fromMasks(): moving from /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt to /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240307_195855/pupdata.txt
/bin/mv -f "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt" "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240307_195855/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 80
out_of_pupil_slopes 2688
lines_to_add 12
residual_pixels_to_add 12
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5 to /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240307_195855
/bin/mv -f "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pup1.fits" "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240307_195855"
'20240307_195855'

test.: '20240307_195855'

lrwxrwxrwx. 1 dxwunit dxwunit 52 Mar 7 20:00 table_LBTI_ACE-AO.txt -> table_LBTI_ACE-AO_20230923_500m_1700Hz.txt.bin4delay

chage bin4 500Hz with the new pupil file


Thu Mar 7 19:52:20.506 2024 aos.Stop{FLAO}.complete - Stop{FLAO}[429]
Thu Mar 7 20:02:11.267 2024 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[430] (aomode:ACE-AO,focst:bentGregorianCenter,instr:LBTI,wfs:LBTIWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.6,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Mar 7 20:02:11.284 2024 aos.info - WFS source set to: LBTIWFS
Thu Mar 7 20:02:11.328 2024 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq500.00_sd3892.fits

pupils seems not right looking at the pupils display.The pupil do not flat when gains applied.

Screen Shot 2024-03-07 at 1.15.02 PM.png

stop

preet and perfor check flux

check flux

bn3 but is seems odd the shape.

adsec skiipping frames.

back to default tables.


Thu Mar 7 20:29:31.721 2024 aos.Stop{FLAO}.complete - Stop{FLAO}[450]
Thu Mar 7 20:33:14.837 2024 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[451] (aomode:ACE-AO,focst:bentGregorianCenter,instr:LBTI,wfs:LBTIWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.6,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Mar 7 20:33:14.851 2024 aos.info - WFS source set to: LBTIWFS
Thu Mar 7 20:33:14.896 2024 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq500.00_sd3892.fits

anothe shift back and forward.

> >> makePupils.movePupils('20200916_173857',0,-1,240,5)
makePupils_fromMasks(): moving from /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt to /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240307_204851/pupdata.txt
/bin/mv -f "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt" "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240307_204851/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 80
out_of_pupil_slopes 2688
lines_to_add 12
residual_pixels_to_add 12
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5 to /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240307_204851
/bin/mv -f "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pup1.fits" "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240307_204851"
'20240307_204851'
>>> makePupils.movePupils('20240307_204851',0,1,240,5)
makePupils_fromMasks(): moving from /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt to /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240307_210010/pupdata.txt
/bin/mv -f "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt" "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240307_210010/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 80
out_of_pupil_slopes 2688
lines_to_add 12
residual_pixels_to_add 12
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5 to /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240307_210010
/bin/mv -f "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pup1.fits" "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240

test.

it still shows a non even illuminated pupils.

> >> makePupils.movePupils('20200916_173857',-1,0,240,5)
makePupils_fromMasks(): moving from /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt to /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240307_211745/pupdata.txt
/bin/mv -f "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt" "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240307_211745/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 80
out_of_pupil_slopes 2688
lines_to_add 12
residual_pixels_to_add 12
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5 to /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240307_211745
/bin/mv -f "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pup1.fits" "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240307_211745"
'20240307_211745'
>>> makePupils.movePupils('20200916_173857',1,0,240,5)
makePupils_fromMasks(): moving from /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt to /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240307_211846/pupdata.txt
/bin/mv -f "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt" "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240307_211846/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 80
out_of_pupil_slopes 2688
lines_to_add 12
residual_pixels_to_add 12
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5 to /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240307_211846
/bin/mv -f "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pup1.fits" "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240307_211846"
'20240307_211846'


restore to zero from previous pupil; 20240307_211745'

> >> makePupils.movePupils('20240307_211745',1,0,240,5)
makePupils_fromMasks(): moving from /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt to /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240307_214405/pupdata.txt
/bin/mv -f "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt" "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240307_214405/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 80
out_of_pupil_slopes 2688
lines_to_add 12
residual_pixels_to_add 12
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5 to /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20240307_214405
/bin/mv -f "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pup1.fits" "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/202

am2/LUTs/mode5/20240307_214405"
'20240307_214405
test the last one: 20240307_214405

Thu Mar 7 21:47:05.627 2024 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[466] (aomode:ACE-AO,focst:bentGregorianCenter,instr:LBTI,wfs:LBTIWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.6,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Mar 7 21:47:05.643 2024 aos.info - WFS source set to: LBTIWFS
Thu Mar 7 21:47:07.891 2024 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq500.00_sd3892.fits

still showing a non even illumnation of the pupils.

cancel the center pupils.

lrwxrwxrwx. 1 dxwunit dxwunit 52 Mar 7 21:46 table_LBTI_ACE-AO.txt~ -> table_LBTI_ACE-AO_20230923_500m_1700Hz.txt.bin4delay
lrwxrwxrwx. 1 dxwunit dxwunit 42 Mar 7 21:50 table_LBTI_ACE-AO.txt -> table_LBTI_ACE-AO_20230923_500m_1700Hz.txt

02:50PM

change left side to Luci to check bin4

check pupil bin4 delay for SX Luyci.

hu Mar 7 23:49:15.720 2024 aos.PresetAO{FLAO}.failed - PresetAO {FLAO}[218] - Illegal command for state PresetOK
Thu Mar 7 23:49:27.732 2024 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[219] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.6,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Mar 7 23:49:27.748 2024 aos.info - WFS source set to: FLAOWFS
Thu Mar 7 23:49:27.791 2024 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq500.0000_sd3892.fits

shutter 48

mag 15.4 ph/sub

pupil: 20230320_000004

optimize:20240307_235943

3.33,1.16,0.1

apply gains TT

get about 60Hz the saturaiton.

Tn:20240308_001945

05:28PM

handover to Guido and Xianyu about a bump in the DX.

Argos cal unit parked.

-- JuanCarlosGuerra - 07 Mar 2024
Topic revision: r4 - 08 Mar 2024, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.