03:30PM

Starting up bcu2k and ocam.

installation of ocam cover. Alessandro installed the cover.

Running ocam in open loop

freq 1700Emgain=1, 0l/D.

To leave the camera running full night.

No events of zero pixels.

Starting day with TT on.

20240305 start ~10am

20240305 22:27:09 pixels_data shape: (100, 40000)
20240305 22:27:09 decimated pixels data shape: (23, 28800)
20240305 22:27:09 mean: [0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0]
20240305 22:27:09 rms: [0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0]
20240305 22:27:09 std: [0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0]
20240305 22:27:09 Alarm Code: 513 (Pixel means for each octant: 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0)

dump for ocam not lve. first set not live, 2nd and 3rdlive

-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 6 06:11 BCUread_23983.202403060000.log
-rw-rw-r--. 1 sxwunit sxwunit 4055 Mar 6 06:11 dumpBCU2KDSP_20240306_061157.txt
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 6 06:11 BCUread_23991.202403060000.log
-rw-rw-r--. 1 sxwunit sxwunit 364432 Mar 6 06:11 dumpBCU2KDSPext1_20240306_061157.txt
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 6 06:11 BCUread_23995.202403060000.log
-rw-rw-r--. 1 sxwunit sxwunit 364476 Mar 6 06:11 dumpBCU2KDSPext2_20240306_061157.txt
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 6 06:11 BCUread_23999.202403060000.log
-rw-rw-r--. 1 sxwunit sxwunit 986435 Mar 6 06:11 dumpBCU2KDSPext3_20240306_061157.txt
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 6 06:11 BCUread_24007.202403060000.log
-rw-rw-r--. 1 sxwunit sxwunit 11962 Mar 6 06:11 dumpBCU2KSRAM_20240306_061157.txt
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 6 06:11 BCUread_24011.202403060000.log
-rw-rw-r--. 1 sxwunit sxwunit 10739 Mar 6 06:11 dumpBCU2KSDRAM_20240306_061157.txt
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 6 06:12 BCUread_27813.202403060000.log
-rw-rw-r--. 1 sxwunit sxwunit 4055 Mar 6 06:12 dumpBCU2KDSP_20240306_061246.txt
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 6 06:12 BCUread_27817.202403060000.log
-rw-rw-r--. 1 sxwunit sxwunit 359942 Mar 6 06:12 dumpBCU2KDSPext1_20240306_061246.txt
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 6 06:12 BCUread_27821.202403060000.log
-rw-rw-r--. 1 sxwunit sxwunit 359975 Mar 6 06:12 dumpBCU2KDSPext2_20240306_061246.txt
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 6 06:12 BCUread_27825.202403060000.log
-rw-rw-r--. 1 sxwunit sxwunit 967875 Mar 6 06:12 dumpBCU2KDSPext3_20240306_061246.txt
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 6 06:12 BCUread_27833.202403060000.log
-rw-rw-r--. 1 sxwunit sxwunit 11962 Mar 6 06:12 dumpBCU2KSRAM_20240306_061246.txt
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 6 06:12 BCUread_27837.202403060000.log
-rw-rw-r--. 1 sxwunit sxwunit 10739 Mar 6 06:12 dumpBCU2KSDRAM_20240306_061246.txt

Stopped TT at 20240305@10PM

Running with modulation 0.

20240306@03:20PM

None zero pixels.

20240306@05:06PM

start mod 3l/D.

20240308

Observed 0800am.

Check log.

SX zero pixels.

saved dump.

-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 8 15:25 BCUread_24648.202403080000.log
-rw-rw-r--. 1 sxwunit sxwunit 4055 Mar 8 15:25 dumpBCU2KDSP_20240308_152512.txt
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 8 15:25 BCUread_24656.202403080000.log
-rw-rw-r--. 1 sxwunit sxwunit 364912 Mar 8 15:25 dumpBCU2KDSPext1_20240308_152512.txt
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 8 15:25 BCUread_24660.202403080000.log
-rw-rw-r--. 1 sxwunit sxwunit 364927 Mar 8 15:25 dumpBCU2KDSPext2_20240308_152512.txt
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 8 15:25 BCUread_24664.202403080000.log
-rw-rw-r--. 1 sxwunit sxwunit 986435 Mar 8 15:25 dumpBCU2KDSPext3_20240308_152512.txt
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 8 15:25 BCUread_24672.202403080000.log
-rw-rw-r--. 1 sxwunit sxwunit 11962 Mar 8 15:25 dumpBCU2KSRAM_20240308_152512.txt
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 8 15:25 BCUread_24676.202403080000.log
-rw-rw-r--. 1 sxwunit sxwunit 10739 Mar 8 15:25 dumpBCU2KSDRAM_20240308_152512.txt

TN:20240308_152558.

20240308

01:32PM MST

ocam not live @20240308 20:18:07

dump saved.

reconfigyre to bin2, ocam live and not live again.

reconfigure.ocam live

1700 mod 0

event:

20240308 21:08:08 pixels_data shape: (100, 40000)
20240308 21:08:08 decimated pixels data shape: (24, 28800)
20240308 21:08:08 mean: [0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0]
20240308 21:08:08 rms: [0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0]
20240308 21:08:08 std: [0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0]
20240308 21:08:08 Alarm Code: 513 (Pixel means for each octant: 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0)

also a ocam not live around 20240308 21:13:37

reconfigure.

OK

TT power off.

ocam not live around ~20240308 21:47:52

bcudump

-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 8 21:54 BCUread_26204.202403080000.log
-rw-rw-r--. 1 sxwunit sxwunit 4055 Mar 8 21:54 dumpBCU2KDSP_20240308_215407.txt
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 8 21:54 BCUread_26208.202403080000.log
-rw-rw-r--. 1 sxwunit sxwunit 364359 Mar 8 21:54 dumpBCU2KDSPext1_20240308_215407.txt
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 8 21:54 BCUread_26212.202403080000.log
-rw-rw-r--. 1 sxwunit sxwunit 364500 Mar 8 21:54 dumpBCU2KDSPext2_20240308_215407.txt
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 8 21:54 BCUread_26217.202403080000.log
-rw-rw-r--. 1 sxwunit sxwunit 986435 Mar 8 21:54 dumpBCU2KDSPext3_20240308_215407.txt
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 8 21:54 BCUread_26237.202403080000.log
-rw-rw-r--. 1 sxwunit sxwunit 11962 Mar 8 21:54 dumpBCU2KSRAM_20240308_215407.txt
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 8 21:54 BCUread_26241.202403080000.log
-rw-rw-r--. 1 sxwunit sxwunit 11314 Mar 8 21:54 dumpBCU2KSDRAM_20240308_215407.txt

python_10523 |DEB| 1857|2024-03-08 21:47:57.177117| MAIN > [aux.auxloops.auxProducer] Error in auxProducer loop: Reading shared buffer masterdiagnostic.L:OPTLOOPBUF - TIMEOUT_ERROR
python_10523 |DEB| 1858|2024-03-08 21:47:57.177355| MAIN >
python_10523 |DEB| 1859|2024-03-08 21:47:57.177383| MAIN > Traceback (most recent call last):
python_10523 |DEB| 1860|2024-03-08 21:47:57.177401| MAIN > File "/home/sxwunit/live/aoroot/lib/python/auxloops/auxProducer.py", line 62, in step
python_10523 |DEB| 1861|2024-03-08 21:47:57.177419| MAIN > self.read()
python_10523 |DEB| 1862|2024-03-08 21:47:57.177436| MAIN > File "/home/sxwunit/live/aoroot/lib/python/auxloops/auxProducer.py", line 45, in read
python_10523 |DEB| 1863|2024-03-08 21:47:57.177463| MAIN > self.shmRecord = self.adapter.readTelemetry( self.flaoBufName, timeout=5.0, simulateSpeed=True)
python_10523 |DEB| 1864|2024-03-08 21:47:57.177480| MAIN > File "/usr/lib/python2.6/site-packages/oaalib/msgdAdapter.py", line 148, in readTelemetry
python_10523 |DEB| 1865|2024-03-08 21:47:57.177496| MAIN > return self.aoapp.BufRead( streamName, timeout=timeout*1000)['data']
python_10523 |DEB| 1866|2024-03-08 21:47:57.177513| MAIN > File "/home/sxwunit/live/aoroot/lib/python/AdOpt/thAOApp.py", line 747, in BufRead
python_10523 |DEB| 1867|2024-03-08 21:47:57.177529| MAIN > raise AdOptError ( code=data['errcode'], errstr='Reading shared buffer '+bufname)
python_10523 |DEB| 1868|2024-03-08 21:47:57.177545| MAIN > AdOptError: Reading shared buffer masterdiagnostic.L:OPTLOOPBUF - TIMEOUT_ERROR
python_10523 |DEB| 1869|2024-03-08 21:48:07.184928| MAIN > [aux.auxloops.auxProducer] Error in auxProducer loop: Reading shared buffer masterdiagnostic.L:OPTLOOPBUF - TIMEOUT_ERROR

zero pixesl.

20240308 22:24:03 valid_pixels shape: (100, 1)
20240308 22:24:03 pixels_data shape: (100, 40000)
20240308 22:24:03 decimated pixels data shape: (24, 28800)
20240308 22:24:03 mean: [0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0]
20240308 22:24:03 rms: [0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0]
20240308 22:24:03 std: [0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0]
20240308 22:24:03 Alarm Code: 513 (Pixel means for each octant: 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0)

reset bcu change binning.

DX shows a strange type of frames.

Saved TN:20240309_002558

saved bcudump.

type of signature:

20240309 00:23:57 mean: [259.42575980392155, 409.99258986928118, 306.36125816993467, 156.40486928104579, 176.57776960784315, 332.97583333333336, 348.8003349673204, 186.28428104575164]
20240309 00:23:57 rms: [166.28787532418053, 198.32459350465734, 186.30390017089533, 155.15265248577617, 175.40425220262804, 171.26977858344321, 196.39217211525934, 184.81996709958202]
20240309 00:23:57 std: [16.054232246097857, 24.819051889671542, 22.057800489443462, 15.158883484985957, 14.471705684693788, 22.186895164428996, 20.686601223210797, 14.609578808468338]

Screen Shot 2024-03-08 at 5.25.05 PM.png

change binning.

OK

Observed same effect.

dump saved.

20240309 04:29:06 decimated pixels data shape: (25, 28800)
20240309 04:29:06 mean: [294.99411111111107, 477.10635555555547, 359.15170000000001, 176.42466666666667, 199.83837777777779, 387.49135555555557, 407.19147777777778, 211.86536666666666]
20240309 04:29:06 rms: [144.0617355126208, 159.31831676239128, 205.00209451165705, 174.19914655752217, 197.77317096015381, 140.1883525618735, 176.50744147868198, 209.91563911360862]
20240309 04:29:06 std: [18.492770354057797, 28.494276461600865, 24.182224675985388, 17.391944100611749, 16.465157007398876, 23.88417881980779, 21.986398687014137, 16.648676789453376]

TN:043030

bcudump.

-rw-rw-r--. 1 dxwunit dxwunit 0 Mar 9 04:29 BCUread_12312.202403090000.log
-rw-rw-r--. 1 dxwunit dxwunit 4120 Mar 9 04:29 dumpBCU2KDSP_20240309_042920.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Mar 9 04:29 BCUread_12316.202403090000.log
-rw-rw-r--. 1 dxwunit dxwunit 363438 Mar 9 04:29 dumpBCU2KDSPext1_20240309_042920.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Mar 9 04:29 BCUread_12324.202403090000.log
-rw-rw-r--. 1 dxwunit dxwunit 363498 Mar 9 04:29 dumpBCU2KDSPext2_20240309_042920.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Mar 9 04:29 BCUread_12328.202403090000.log
-rw-rw-r--. 1 dxwunit dxwunit 986407 Mar 9 04:29 dumpBCU2KDSPext3_20240309_042920.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Mar 9 04:29 BCUread_12332.202403090000.log
-rw-rw-r--. 1 dxwunit dxwunit 11962 Mar 9 04:29 dumpBCU2KSRAM_20240309_042920.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Mar 9 04:29 BCUread_12340.202403090000.log
-rw-rw-r--. 1 dxwunit dxwunit 10739 Mar 9 04:29 dumpBCU2KSDRAM_20240309_042920.txt

image without the background.

Screen Shot 2024-03-08 at 9.31.12 PM.png

change bin

OK.

20240309@08:00am

DX. power off TT

NO issues.

20240310@12:30am

(07:30)

Power on TT. DX/SX (?), the lbti web page doen't come up, probably server down.

-- JuanCarlosGuerra - 04 Mar 2024