Staff:

lbto: Juan Carlos

Observer: NA

Summary.

  • Continuing testing the zero slope firmware upgrade for soul-lucisx and dx. The test has not shown any zero slopes events for the time that the loop was closed.
  • Executed pause/resume events an change bnning without problems.
  • Nto issues wth loop stability or performances.
  • Loop closed with disturbances on for 0.8" seeing.

Details.

SoulSX.

runs version.

ocam with some bad quadrants.

TN:20240219_183305

Aux loop doen not works due to the Badframe task. To be checked with Brandon.

SoulDX

run version.

power cycle bcu2k

reconfgure bin from wfscontrol gui

not luck

Tn:_190000

Second try.

OK.

TN:_190355

Preset to a bright object 2.3 and the center pupils failed because there is amistmach in the configuration to do the close loop.

ator_2241 |DEB| 283|2024-02-19 18:46:48.125629| MAIN > arbFunc doCenterPupils (, 'FLAOWFS', 'LUCIFER')
WfsArbitrator_2241 |ERR| 284|2024-02-19 18:46:48.137107| MAIN > RETRY: Error setting modulation: Amplitude 20.0 for frequency 1700 is not allowed by the TT interpolation table - VALUE_OUT_OF_RANGE_E

change to mag10.0

saved TN: _185531,_185552,_185605

pase/resumex5

OK.

stop.

Mon Feb 19 19:16:25.624 2024 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[6697] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:-0.03[-0.03],roy:0,mag:12.7,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Feb 19 19:16:25.646 2024 aos.info - WFS source set to: FLAOWFS
Mon Feb 19 19:16:25.760 2024 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.6_L040.0_v15.0_ovfreq1700.00_sd3892.fits

..

Mon Feb 19 19:18:46.005 2024 aos.info - Updated variable AOARB.R.SL_READY: 1
Mon Feb 19 19:18:46.039 2024 aos.info - Updated variable AOARB.R.AO_READY: 1
Mon Feb 19 19:19:36.067 2024 aos.warning - FLAO: Error for Variable:aos.side[1].wfs_select AOException: Error writing variable - -5001: Timeout error

TN:_194510,_194524,_194537

change version of SW software.

Brandon integrated the changes of phase 1.5 to the current zero slope firmaware testing version.

Currently running: test.20240125.zero-slope-firmware (soul)

Mon Feb 19 21:33:06.474 2024 aos.Stop{FLAO}.complete - Stop{FLAO}[3038]
Mon Feb 19 21:33:39.978 2024 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[3039] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Feb 19 21:33:39.999 2024 aos.info - WFS source set to: FLAOWFS
Mon Feb 19 21:33:40.036 2024 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.6_L040.0_v15.0_ovfreq1700.00_sd3892.fits
Mon Feb 19 21:33:40.871 2024 aos.info - FLAO: WFS: loading setup for LUCIFER

TN:

_215647,_215715,_215746

_215645,_215717,_215748

Stop 03:00

-- JuanCarlosGuerra - 19 Feb 2024
Topic revision: r3 - 19 Feb 2024, JuanCarlosGuerra