Details.

Version deployed

Currently running: test.20240125.zero-slope-firmware (soul)

Power on SX.

ocam with bad.

TN:20240216_195420

power cycle bcu2k

preset DX

Fri Feb 16 20:15:52.246 2024 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[6303] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Feb 16 20:15:52.262 2024 aos.info - WFS source set to: FLAOWFS

Fri Feb 16 20:16:00.841 2024 aos.info - FLAO: WFS: configuring CCDs
Fri Feb 16 20:19:01.891 2024 aos.PresetAO{FLAO}.failed - PresetAO {FLAO}[6303] - [AOException] presetAO: FATAL - Reading shared buffer mirrorctrl.R:TECHVIEWER_65536 (-5001) TIMEOUT_ERROR
Fri Feb 16 20:20:09.112 2024 aos.warning - FLAO: Error for Variable:oss.side[1].terc.abs_pos[0] AOException: Error writing variable - -5001: Timeout error
Fri Feb 16 20:25:20.874 2024 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[6304] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Feb 16 20:25:20.894 2024 aos.info - WFS source set to: FLAOWFS
Fri Feb 16 20:25:21.369 2024 aos.info - FLAO: WFS: loading setup for LUCIFER

change bin ccd47

SX.

Error to power on.

PicCtrlW2 _127626 |INF| 3625|2024-02-16 20:30:15.270231| MAIN > Connecting to ts8dx, 3108
PicCtrlW2_127626 |ERR| 3626|2024-02-16 20:30:15.273103| MAIN > Error configuring network, errno=Connection refused
PicCtrlW2_127626 |INF| 3627|2024-02-16 20:30:15.473448| MAIN > Connecting to ts8dx, 3108
PicCtrlW2_127626 |ERR| 3628|2024-02-16 20:30:15.476114| MAIN > Error configuring network, errno=Connection refused
PicCtrlW2_127626 |INF| 3629|2024-02-16 20:30:15.676449| MAIN > Connecting to ts8dx, 3108
PicCtrlW2_127626 |ERR| 3630|2024-02-16 20:30:15.679208| MAIN > Error configuring network, errno=Connection refused
PicCtrlW2_127626 |INF| 3631|2024-02-16 20:30:15.879534| MAIN > Connecting to ts8dx, 3108
PicCtrlW2_127626 |ERR| 3632|2024-02-16 20:30:15.882421| MAIN > Error configuring network, errno=Connection refused
PicCtrlW2_127626 |INF| 3633|2024-02-16 20:30:16.082797| MAIN > Connecting to ts8dx, 3108
PicCtrlW2_127626 |ERR| 3634|2024-02-16 20:30:16.085472| MAIN > Error configuring network, errno=Connection refused
PicCtrlW2_127626 |INF| 3635|2024-02-16 20:30:16.285866| MAIN > Connecting to ts8dx, 3108
PicCtrlW2_127626 |ERR| 3636|2024-02-16 20:30:16.288609| MAIN > Error configuring network, errno=Connection refused
PicCtrlW2_127626 |INF| 3637|2024-02-16 20:30:16.488974| MAIN > Connecting to ts8dx, 3108
PicCtrlW2_127626 |ERR| 3638|2024-02-16 20:30:16.491890| MAIN > Error configuring network, errno=Connection refused
PicCtrlW2_127626 |INF| 3639|2024-02-16 20:30:16.692180| MAIN > Connecting to ts8dx, 3108
PicCtrlW2_127626 |ERR| 3640|2024-02-16 20:30:16.694851| MAIN > Error configuring network, errno=Connection refused
PicCtrlW2_127626 |INF| 3641|2024-02-16 20:30:16.895143| MAIN > Connecting to ts8dx, 3108
PicCtrlW2_127626 |ERR| 3642|2024-02-16 20:30:16.897975| MAIN > Error configuring network, errno=Connection refused
PicCtrlW2_127626 |INF| 3643|2024-02-16 20:30:17.098312| MAIN > Connecting to ts8dx, 3108
PicCtrlW2_127626 |ERR| 3644|2024-02-16 20:30:17.101113| MAIN > Error configuring network, errno=Connection refused
PicCtrlW2_127626 |INF| 3645|2024-02-16 20:30:17.301456| MAIN > Connecting to ts8dx, 3108
PicCtrlW2_127626 |ERR| 3646|2024-02-16 20:30:17.304333| MAIN > Error configuring network, errno=Connection refused
PicCtrlW2_127626 |INF| 3647|2024-02-16 20:30:17.504728| MAIN > Connecting to ts8dx, 3108
PicCtrlW2_127626 |ERR| 3648|2024-02-16 20:30:17.507544| MAIN > Error configuring network, errno=Connection refused
PicCtrlW2_127626 |INF| 3649|2024-02-16 20:30:17.707908| MAIN > Connecting to ts8dx, 3108
PicCtrlW2_127626 |ERR| 3650|2024-02-16 20:30:17.710489| MAIN > Error configuring network, errno=Connection refused

set ocam to ambient.

Troubleshoot of the power on failure and not connecting to ts8dx.

it seems some intermittent connection.

w_stop/start_all

DX in close loop

TN:20240216_204654,_204711,_

after the sofware restart it seems connected to the rest of devices.

The cube stage/lamo and cub rotator shows to be offline.

Power off manual from HW gui

restart soft.

Screen Shot 2024-02-16 at 1.49.32 PM.png

Call Alessandro. He is working with the ocam spare.

Alessandro power off and disconnect the processes.

w_stop/start_all for soul-luciSX.

All come back correctly.

Leave Alessandro tests off.

SoulDX continues in close loop not issues.

02:40PM

Handover to telescope for refills and close.

Revert sw versiot to phase 1

-- JuanCarlosGuerra - 16 Feb 2024
Topic revision: r2 - 16 Feb 2024, JuanCarlosGuerra