Staff.

lbto: Josh, Justin, Juan CArlos, greg

Observer: Fernando (shark-vis). RE mote Italy.

Shark-Nir (luca). remote Italy.

INAF. Elena. Remote Italy

Forecast.

forecast0_20240215.png

forecast1_20240215.png

Details.

SharkVis email.

"Fernando.,

a short summary about the tonight's plan for SHARK-VIS:

1) Primary target CQ tau (back-up on MWC758)

2) AO config on DX: "WINDOW" and we will try both dichros (LMIRCam and
H-alpha) with their relative config files with _LP suffix for ncpa and
BAYSIDE. We will do the observation with the most trasmissive once
verified on sky.

3) about 2 hours of observation on the selected target

4) telescope passes to INAF around 4:00 UT

Final remark: last night we noticed that the seeing was improving after
the first hour, may be due to the telescope going to thermal equilibrium
once the dome opened to sky. Is it possible to anticipate the open and
venting of the dome to 40min before sunset?"

cq_tau.png

04:47

POWER ON LBTIDXWFS.

ocam OK

Fri Feb 16 01:21:46.179 2024 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[6210] (aomode:ACE-AO,focst:bentGregorianCenter,instr:SHARK,wfs:LBTIWFS,sox:0[0],soy:0,rox:-0.0496688[-0.0496688],roy:7.59166e-08,mag:-0.37,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

pointng done.

Z +3

z#7 -100

close loop

TN:_20240216

TN:_015101

seeing 1.7

Optimize

pause

insert window.

take background improvce the counts. total counts ~2000

TN:_200116,_200139,_

optimize

TN:_021028,_021051,_021109

optimize

TN:_021448,_021512,_021536

TN:_022254,_022310,_022324

2 open loops:
  • python_54896 |ERR| 162|2024-02-16 02:06:45.167245| MAIN > Alert from AdSec [177] - SkipFrame
  • python_54896 |DEB| 163|2024-02-16 02:06:45.167286| MAIN > Sending to 3 clients: SkipFrame
  • python_54896 |ERR| 177|2024-02-16 02:11:31.270329| MAIN > Alert from AdSec [177] - SkipFrame
  • python_54896 |DEB| 178|2024-02-16 02:11:31.270352| MAIN > Sending to 3 clients: SkipFrame
Fri Feb 16 01:31:29.316 2024 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[6218] (aomode:ACE-AO,focst:bentGregorianCenter,instr:SHARK,wfs:LBTIWFS,sox:0[0],soy:0,rox:-0.0602428[-0.0602428],roy:2.39787e-07,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

seeing 1.5

TN:_023611,_023637,_023651

07:42

seeing to 2"

drop two clocks gains to avoid skipping

024306,_024324,_024345,_024409,_024424

Reduced ho2 t20 cloickc seeing 2.2"

for stability

TN:_024950,_

improved

TN:_025136,_

seeing 2.1

stopDX and SX

seeing not good

08:00

Handover to INAF

-- JuanCarlosGuerra - 15 Feb 2024
Topic revision: r3 - 16 Feb 2024, JuanCarlosGuerra