Details.

Power on from AOS.

WfsArbitrator_36993|INF| 75|2024-02-06 15:36:22.316059| MAIN > Missing network connection with ts8 dx. Check network cable and 110V line - TIMEOUT_ERROR
WfsArbitrator_36993|ERR| 76|2024-02-06 15:36:22.316145| MAIN > Exception: Missing network connection with ts8 dx. Check network cable and 110V line
WfsArbitrator_36993|ERR| 77|2024-02-06 15:36:22.316190| MAIN > Missing network connection with ts8 dx. Check network cable and 110V line (-5001) TIMEOUT_ERROR

Power on from wfscontrol gui.

WfsArbitrator_36993|INF| 97|2024-02-06 15:39:38.926579| MAIN > Turning on RESET_BCU_2K
WfsArbitrator_36993|INF| 98|2024-02-06 15:40:14.048767| MAIN > Timeout waiting for pinger.L.bcu2k - TIMEOUT_ERROR
WfsArbitrator_36993|ERR| 99|2024-02-06 15:40:14.048869| MAIN > Exception: Timeout waiting for pinger.L.bcu2k
WfsArbitrator_36993|ERR| 100|2024-02-06 15:40:14.048915| MAIN > Timeout waiting for pinger.L.bcu2k (-5001) TIMEOUT_ERROR

Iy is not connected to the ts8dx.

Pinger_40311 |INF| 1148|2024-02-06 15:46:37.433560| MAIN > Host ts8dx: -1.000000 [ms]
Pinger_40311 |INF| 1149|2024-02-06 15:46:37.433655| MAIN > Host ts8: 0.553000 [ms]
Pinger_40311 |INF| 1150|2024-02-06 15:46:40.435145| MAIN > Host bcu2k: -1.000000 [ms]
Pinger_40311 |INF| 1151|2024-02-06 15:46:40.435441| MAIN > Host bcu47: -1.000000 [ms]
Pinger_40311 |INF| 1152|2024-02-06 15:46:40.435554| MAIN > Host ts8dx: -1.000000 [ms]
Pinger_40311 |INF| 1153|2024-02-06 15:46:40.435648| MAIN > Host ts8: 0.609000 [ms]
Pinger_40311 |INF| 1154|2024-02-06 15:46:43.436886| MAIN > Host bcu2k: -1.000000 [ms]
Pinger_40311 |INF| 1155|2024-02-06 15:46:43.437155| MAIN > Host bcu47: -1.000000 [ms]
Pinger_40311 |INF| 1156|2024-02-06 15:46:43.437240| MAIN > Host ts8dx: -1.000000 [ms]
Pinger_40311 |INF| 1157|2024-02-06 15:46:43.437356| MAIN > Host ts8: 0.629000 [ms]
Pinger_40311 |INF| 1158|2024-02-06 15:46:46.438602| MAIN > Host bcu2k: -1.000000 [ms]
Pinger_40311 |INF| 1159|2024-02-06 15:46:46.438874| MAIN > Host bcu47: -1.000000 [ms]
Pinger_40311 |INF| 1160|2024-02-06 15:46:46.438962| MAIN > Host ts8dx: -1.000000 [ms]
Pinger_40311 |INF| 1161|2024-02-06 15:46:46.439068| MAIN > Host ts8: 0.634000 [ms]
Pinger_40311 |INF| 1162|2024-02-06 15:46:49.440354| MAIN > Host bcu2k: -1.000000 [ms]
Pinger_40311 |INF| 1163|2024-02-06 15:46:49.440618| MAIN > Host bcu47: -1.000000 [ms]
Pinger_40311 |INF| 1164|2024-02-06 15:46:49.440706| MAIN > Host ts8dx: -1.000000 [ms]

restart SW.

w_stop/start_all

OK.

time out the rerotator.

There is popup but t here is not any WAR or ERR in the wfsarb log or display.

AOS logging

Tue Feb 6 15:50:35.812 2024 aos.info - FLAO: WFS: starting power on sequence
Tue Feb 6 15:50:38.859 2024 aos.info - FLAO: WFS: setting up BCUs...
Tue Feb 6 15:50:54.477 2024 aos.info - FLAO: WFS: setting up flowerpot...

WFs arb logging.

WfsArbitrator_79227|DEB| 129|2024-02-06 15:56:49.906296| MAIN > arbFunc updateModulationInternal (, 'FLAOWFS', '', 1000)
WfsArbitrator_79227|INF| 130|2024-02-06 15:56:49.907205| MAIN > Setting tiptilt to amp= 0.00, freq= 0.00, offx= 0.00, offy= 0.00
WfsArbitrator_79227|DEB| 131|2024-02-06 15:56:49.907476| MAIN > arbFunc updateModulationInternal done.

To improve the dsplay information.

The AOS shows to the operating and all seems OK. To be corrected.

Repeat.

It is not turning on the pupl rerotator.,

WfsArbitrator_79227|INF| 190|2024-02-06 16:05:07.000058| MAIN > Setting up rerotator
WfsArbitrator_79227|INF| 191|2024-02-06 16:05:07.000213| MAIN > Turning on REROT_POWER

WfsArbitrator_79227|INF| 191|2024-02-06 16:05:07.000213| MAIN > Turning on REROT_POWER
WfsArbitrator_79227|INF| 192|2024-02-06 16:07:07.001006| MAIN > Timeout waiting for rerotator.L.STATUS - TIMEOUT_ERROR
WfsArbitrator_79227|ERR| 193|2024-02-06 16:07:07.001154| MAIN > Exception: Timeout waiting for rerotator.L.STATUS
WfsArbitrator_79227|ERR| 194|2024-02-06 16:07:07.001237| MAIN > Timeout waiting for rerotator.L.STATUS (-5001) TIMEOUT_ERROR

w_stop/start_all

It seems that it is not connected, the check ion the housekeeper shows to have power 23v.

wehn OK. connection on.

Checking the process shows more detail than before.

Most probably it was required to a restart oft he process.

OCAM OK.

ue Feb 6 16:33:31.543 2024 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[1214] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Feb 6 16:33:31.561 2024 aos.info - WFS source set to: FLAOWFS
Tue Feb 6 16:33:31.606 2024 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.6_L040.0_v15.0_ovfreq1700.00_sd3892.fits

TN:20240206_164409,_165114

pause/resume x5

OK

TN+luci:_170029

TN+luci:_170208 (subwin)

_170332 (subw 100)

decrease in performances. sloperms went from 0.9 to 1.06 SR went below 80%, PSF looks not too good.

optimized

TT solution 1.16

move TT up to 1.51

optimize

TN+luci: _171103,_171911(ncpa),

Stop ncpa

adsce failure.

Probably due to the ncpagui iteration.

adsc-stop/start

wfs_stop/start_all

Preset agan.

taking dark, not light.

Alram code #32

TN+luci: _180646

corrected focus from 52.9 to 51.4

TN+luci:_181018,_181158(ncpa),_

change bin to 2

code#128

ocam ok

the applicaiton of the first dark af

illumination error dring the center pupil. The loop remain in close loop.

this should be an alarm and a stopAO.

Tue Feb 6 18:42:27.192 2024 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[1247] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:12.9,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Feb 6 18:42:27.208 2024 aos.info - WFS source set to: FLAOWFS
Tue Feb 6 18:42:27.251 2024 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1000.00_sd3892.fits

TN+luci:_185547,_190038

focus check.

51.6

TN:_193136,_193324,_193411,_193711 (no ncpa)

_194118(ncpa),_194122(ncpa)

set z#5 -10

TN:_195303,_195333,_195352

z#5 -10

scanning z#6

z#610

TN:_200010,_200059,_200129

stopAO.

configuring to bin1.

Tue Feb 6 20:57:57.095 2024 aos.info - FLAO: WFS: loading setup for LUCIFER
Tue Feb 6 20:58:42.779 2024 aos.info - FLAO: WFS: configuring CCDs
  • went ocam not live.
  • and back live.
  • < probably the update of the ocam viewer>
Alarm code #64

two bad octants.

TN:_210206

restart bcu2k

change bin2 from wfscontrol gui.

Alarm #160

change to bin 1

OK

Tue Feb 6 21:06:37.540 2024 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[1258] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Feb 6 21:06:37.558 2024 aos.info - WFS source set to: FLAOWFS
Tue Feb 6 21:06:37.598 2024 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.6_L040.0_v15.0_ovfreq1700.00_sd3892.fits

TN:_211744,_211805 (foc 52..9)

_212332 (foc 51.6),_212418,

_212419(ncpa),_212522(ncpa)

z#5-10,z#6+10: _212522,_212634,_212933,_212956

no dist.

_214008,_214038 foc 52.9

foc 51.6

_214212,_214231

ncpa:

_214257,_214316

-10,10

_214402,_214421

scanning Z8

dark 97,98,99

StopAO

02:57

-- JuanCarlosGuerra - 06 Feb 2024