Staff:

LBTO: Brandon, Juan Carlos

Observer: Fabio (Arcetri rremote)

Summary.

Test the zero slope firmaware update from mario and checkout that the correct software is loaded.

Auxloop improvements for discrepancy of ocam viewer counts and auxloop counts.

Close loop with new firmware.

Fabio's notes:

- auxloops log file: finally moving to the log folder instead of the bin folder

- badOcamFramesTask: should be suspended and do nothing when the Ocam is being reconfigured (framerate, emGain or binning are changed and/or a dark is being acquired)

The commits are in the pull request from the last time ((FRO) Update to use new BCU2K firmware version (tentative Slope 0 fix). #206), I leave it to you how to best handle the checkout of this code.

Details.

08:30am

Power on SX.

loaded the zero slope SW.

Fabio connected.

WFS power up.

Ocam not OK, bad quadrants and triangle.

TN:20240125_160455

badframe logs it is not reporting a bad quadrant.

20240125_badframe.png

240125 16:16:32 rms: [54.123474669125827, 63.98365970242773, 63.756320665456442, 51.33991172237495, 51.24910884476887, 63.745410263753072, 60.835840090119035, 50.151449023448308]
20240125 16:16:32 std: [4.0998446908814525, 4.3542740904042621, 38.23546599112624, 4.2462974669919209, 4.0035653674847413, 32.147883463760998, 3.4346384980932716, 2.6121775081075218]
20240125 16:16:35 mean: [188.33135313531361, 191.50948019801982, 188.83663641364137, 186.49303355335536, 186.55995874587458, 189.05911716171624, 185.14183168316828, 185.94310231023104]
20240125 16:16:35 rms: [54.022342690989205, 64.0344846298063, 63.767566175476531, 51.380996544053033, 51.253221143732233, 63.560762399479792, 61.100387758912461, 50.177834236059148]
20240125 16:16:35 std: [4.1019730908135212, 4.3564329838238587, 33.664446321985714, 4.2660053712737316, 4.0238957239006874, 30.990391694210963, 3.4479020907000133, 2.6123615724553044]
20240125 16:16:37 mean: [188.35670277777774, 191.47425555555554, 188.92808611111118, 186.48773333333338, 186.5416361111111, 189.10950833333328, 185.16081111111106, 185.91735277777778]
20240125 16:16:37 rms: [52.788724604067291, 62.645746648478124, 62.537660706866184, 50.046697038981229, 49.907205391199604, 62.187366356244667, 59.663770758022523, 48.944465634084175]
20240125 16:16:37 std: [4.1013763769112002, 4.3519968806761966, 35.537644210446196, 4.2964129346915385, 4.1526405730869564, 37.282140731710676, 3.4433002250014897, 2.610714735622722]
20240125 16:16:40 mean: [188.33053104575166, 191.4845343137255, 188.94141339869284, 186.49522875816993, 186.51306917211332, 189.19775871459697, 185.11699618736384, 185.92209694989106]
20240125 16:16:40 rms: [55.280595771449121, 64.580831185750569, 64.729815396399701, 52.467670458008207, 52.40334695299677, 64.464463057896708, 61.884614289493861, 51.558294232271521]
20240125 16:16:40 std: [4.1007462363315037, 4.3470729853966148, 33.712501513827938, 4.1855898388122146, 3.9438823355530737, 44.717966541315739, 3.4341940890838711, 2.6063298512442246]
20240125 16:16:43 mean: [188.34140833333331, 191.48583055555551, 188.92871388888892, 186.48763333333335, 186.47934444444439, 188.8405027777778, 185.12943611111115, 185.94320277777777]
20240125 16:16:43 rms: [52.739968630085933, 62.679089933207422, 62.480420825559413, 50.079306134866243, 49.976926641918382, 62.572024247101666, 59.584500923777988, 48.846125375857952]
20240125 16:16:43 std: [4.1041757857222247, 4.3543959421863514, 32.127734695898113, 4.4475177778214823, 4.2009462024644968, 32.999689689996437, 3.4370520785054106, 2.6057358688511698]

Working with new zero slope SW.

09:10am

software version, checks, clean and compile.

09:20am

Power off.

Working in a new version. Clean/compile

09:34 am

power on.

power board went down looking at the HW GUi.

- check the P2K controller log. It is not reporting any thing.

Power cycle the process. The keepup process start up again.

log is scrolling, the HW indicator comes back on (green)

Operate

ocam not live.

set looop param

not live.

recycle masterdiagnotic. No luck.

set loop param:

no luck.

Power cycle bcu2k+set to bin2

Ocam OK.

10:16

New SW version.

test.20240125.zero-slope-firmware
[AOeng@soul-sxwfs source]$ use_soul test.20240125.zero-slope-firmware
Switched live version to /home/AOeng/soul/test.20240125.zero-slope-firmware.
[AOeng@soul-sxwfs source]$ w_start_all

w_start_all

Error to bring up the auxloop


python_155744 |DEB| 2588|2024-01-25 17:01:22.024405| MAIN > File "/home/AOeng/live/aoroot/lib/python/auxloops/auxProducer.py", line 45, in read
python_155744 |DEB| 2589|2024-01-25 17:01:22.024424| MAIN > self.shmRecord = self.adapter.readTelemetry( self.flaoBufName, timeout=1.0, simulateSpeed=True)
python_155744 |DEB| 2590|2024-01-25 17:01:22.024443| MAIN > File "/usr/lib/python2.6/site-packages/oaalib/msgdAdapter.py", line 148, in readTelemetry
python_155744 |DEB| 2591|2024-01-25 17:01:22.024461| MAIN > return self.aoapp.BufRead( streamName, timeout=timeout*1000)['data']
python_155744 |DEB| 2592|2024-01-25 17:01:22.024485| MAIN > File "/home/AOeng/live/aoroot/lib/python/AdOpt/thAOApp.py", line 747, in BufRead
python_155744 |DEB| 2593|2024-01-25 17:01:22.024504| MAIN > raise AdOptError ( code=data['errcode'], errstr='Reading shared buffer '+bufname)
python_155744 |DEB| 2594|2024-01-25 17:01:22.024522| MAIN > AdOptError: Reading shared buffer masterdiagnostic.L:OPTLOOPBUF - TIMEOUT_ERROR
python_155744 |INF| 2595|2024-01-25 17:14:41.574444| MAIN > TERMINATE received. Its TimeToDie.
python_155744 |DEB| 2596|2024-01-25 17:14:41.733037| MAIN > [aux.auxloops.auxMain] Terminating all child processes
python_108113 |DEB| 1|2024-01-25 17:16:15.719055| MAIN > Connected as auxloops.L

FAbio: debug the issue.

Task: Aux loop logs in the ADOPT_LOG.

-> OK.

power on reports an error.

ocam2k remain powered OFF.

Screen Shot 2024-01-25 at 10.37.39 AM.png

Fabio debug.

Fixed.

power on OK.

OCam not live.

Change loop param

no Luck.

REstart masterdiagn

no luck.

Power cycle bcu2k

change bin

OK.

Task. Stop badframe task when bin changes.

0240125 18:05:15 std: [2.4578827868481778, 2.7919295292648449, 2.4837495405089536, 1.4587606402056332, 1.2968623244235893, 1.8518976355119996, 2.489429920673909, 1.4620605031592939]
20240125 18:05:17 Suspended because Ocam is not valid
20240125 18:05:37 Suspended because Ocam is not valid
20240125 18:05:39 mean: [94.014551282051272, 95.605141559829079, 92.566116452991452, 92.835021367521364, 93.374866452991455, 95.094778311965811, 92.383677884615366, 92.75005876068377

bin4.

Not executed correctly.

when the change binning applying the loop parameters from the wfscontrol gui. The software is trying to get a pupil file.

There is a wrong pupil fle because it is looking at the backup directory.

Traceback (most recent call last):
File "/home/AOeng/live/aoroot/lib/python/auxloops/auxTask.py", line 388, in run
self.calcUser()
File "/home/AOeng/live/aoroot/lib/python/auxloops/tasks/badFramesTask/badFramesTask.py", line 99, in calcUser
display_table_file = open(display_table_name, "r")
IOError: [Errno 2] No such file or directory: '/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/current/display'
20240125 18:08:14 Exception in task BadFramesTask loop: [Errno 2] No such file or directory: '/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/current/display'

Traceback (most recent call last):
File "/home/AOeng/live/aoroot/lib/python/auxloops/auxTask.py", line 388, in run
self.calcUser()
File "/home/AOeng/live/aoroot/lib/python/auxloops/tasks/badFramesTask/badFramesTask.py", line 99, in calcUser
display_table_file = open(display_table_name, "r")
IOError: [Errno 2] No such file or directory: '/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/current/display'
20240125 18:08:16 Exception in task BadFramesTask loop: [Errno 2] No such file or directory: '/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/current/display'

Traceback (most recent call last):
File "/home/AOeng/live/aoroot/lib/python/auxloops/auxTask.py", line 388, in run
self.calcUser()
File "/home/AOeng/live/aoroot/lib/python/auxloops/tasks/badFramesTask/badFramesTask.py", line 99, in calcUser
display_table_file = open(display_table_name, "r")
IOError: [Errno 2] No such file or directory: '/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/current/display'

xrwxr-x. 7 AOeng AOeng 4096 Jan 25 16:17 m4shifts/
lrwxrwxrwx. 1 AOeng AOeng 65 Jan 25 18:08 current -> /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/backup/
solved.

Moved the backup file.

OK

Task. Bad frame mean counts vs Ocam viewer counts.

comparison of the values of mean (no background substracted) from ocam viewer and bad frame mean

11:33

Found the bug.

The frames are decimated and at the time to compute.

12:10PM

STOP

Reconcile for next time and Fabio will have a badframe task.

Countinue to test in close loop the current firmware version.

12:20PM

Close loop.

deploy argos cal unit.

Thu Jan 25 19:26:10.142 2024 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[3533] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Jan 25 19:26:10.157 2024 aos.info - WFS source set to: FLAOWFS
Thu Jan 25 19:26:10.926 2024 aos.info - FLAO: WFS: loading setup for LUCIFER
Thu Jan 25 19:26:10.943 2024 aos.info - FLAO: WFS: configuring CCDs

close loop No gopt .

dump bcu.

-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:32 BCUread_169187.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 4133 Jan 25 19:32 dumpBCU2KDSP_20240125_193251.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:32 BCUread_169191.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 364048 Jan 25 19:32 dumpBCU2KDSPext1_20240125_193251.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:32 BCUread_169195.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 365386 Jan 25 19:32 dumpBCU2KDSPext2_20240125_193251.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:32 BCUread_169199.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 986143 Jan 25 19:32 dumpBCU2KDSPext3_20240125_193251.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:32 BCUread_169209.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 11962 Jan 25 19:32 dumpBCU2KSRAM_20240125_193251.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:32 BCUread_169213.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 11341 Jan 25 19:32 dumpBCU2KSDRAM_20240125_193251.txt

Thu Jan 25 19:35:08.703 2024 aos.Stop{FLAO}.complete - Stop{FLAO}[3536]
Thu Jan 25 19:35:18.163 2024 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[3537] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Jan 25 19:35:18.179 2024 aos.info - WFS source set to: FLAOWFS
Thu Jan 25 19:35:18.216 2024 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.6_L040.0_v15.0_ovfreq1700.00_sd3892.fits

loop closed +gopt

-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:44 BCUread_11532.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 4133 Jan 25 19:44 dumpBCU2KDSP_20240125_194401.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:44 BCUread_11539.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 364541 Jan 25 19:44 dumpBCU2KDSPext1_20240125_194401.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:44 BCUread_11543.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 364706 Jan 25 19:44 dumpBCU2KDSPext2_20240125_194401.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:44 BCUread_11549.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 986145 Jan 25 19:44 dumpBCU2KDSPext3_20240125_194401.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:44 BCUread_11557.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 11962 Jan 25 19:44 dumpBCU2KSRAM_20240125_194401.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:44 BCUread_11567.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 10738 Jan 25 19:44 dumpBCU2KSDRAM_20240125_194401.txt

--

pause/resume.

20240125 19:50:54 std: [20.438940679551013, 2.7132296008526766, 3.5888489595788688, 8.2681393803198073, 20.30829724865664, 2.3210802814421667, 2.6823767706231005, 8.2106631805343309]
20240125 19:50:56 mean: [111.65714796479651, 100.09426017601761, 98.277070957095717, 100.47686743674367, 106.45218371837186, 99.914623212321231, 97.261221122112232, 99.195173267326751]
20240125 19:50:56 rms: [42.896769599508907, 42.07202779519406, 39.031892014127365, 40.211881152785587, 42.096006365351066, 41.583709985486827, 35.491639595791398, 38.564364797610466]
20240125 19:50:56 std: [24.556308164344209, 2.7326976321993421, 3.5886101648710054, 7.2065233077324624, 18.463424631669849, 2.3194073854123882, 2.6920656437679322, 4.7232516987161164]
20240125 19:50:56 Alarm Code: 128 (Pixel means for each octant: 111.657147965, 100.094260176, 98.2770709571, 100.476867437, 106.452183718, 99.9146232123, 97.2612211221, 99.1951732673)
20240125 19:50:59 mean: [103.31081111111106, 99.167263888888883, 97.480202777777777, 102.76177500000001, 102.724975, 98.977538888888901, 96.320997222222232, 102.35947222222221]
20240125 19:50:59 rms: [42.166702270883995, 40.637543555581779, 37.675192973243881, 41.497122341805813, 41.543553872985164, 40.116616496598368, 33.899480182692422, 40.610805375905734]
20240125 19:50:59 std: [9.2773948922081289, 2.7217602916786552, 3.5684093427995887, 8.800638292739098, 8.9344952808489033, 2.3164426955252146, 2.6802381560413675, 9.1004920113595151]
20240125 19:51:02 mean: [97.301696623093704, 93.322355664488029, 91.731767429193908, 96.558755446623124, 96.836669389978226, 93.146092047930281, 90.654534313725492, 96.406342592592566

TN:20240125_195233

slope zero.

,,,,

Filler_190965 |INF| 271080|2024-01-25 19:54:02.402711| MAIN > insert into optloopdiag_L_COUNTS (date_t,time_t,optloopdiag_L_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),45461)
DBFiller_190965 |INF| 271089|2024-01-25 19:54:03.001928| MAIN > insert into optloopdiag_L_SLOPERMS (date_t,time_t,optloopdiag_L_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),0.422968)
DBFiller_190965 |INF| 271149|2024-01-25 19:54:04.416411| MAIN > insert into optloopdiag_L_COUNTS (date_t,time_t,optloopdiag_L_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),45461)
DBFiller_190965 |INF| 271158|2024-01-25 19:54:05.018282| MAIN > insert into optloopdiag_L_SLOPERMS (date_t,time_t,optloopdiag_L_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),0)
DBFiller_190965 |INF| 271202|2024-01-25 19:54:06.429600| MAIN > insert into optloopdiag_L_COUNTS (date_t,time_t,optloopdiag_L_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),45461)

recording dumps during slopezero.

w-rw-r--. 1 AOeng AOeng 0 Jan 25 19:55 BCUread_60281.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 4134 Jan 25 19:55 dumpBCU2KDSP_20240125_195507.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:55 BCUread_60285.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 358368 Jan 25 19:55 dumpBCU2KDSPext1_20240125_195507.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:55 BCUread_60289.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 358477 Jan 25 19:55 dumpBCU2KDSPext2_20240125_195507.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:55 BCUread_60301.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 986141 Jan 25 19:55 dumpBCU2KDSPext3_20240125_195507.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:55 BCUread_60309.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 11962 Jan 25 19:55 dumpBCU2KSRAM_20240125_195507.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:55 BCUread_60313.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 10738 Jan 25 19:55 dumpBCU2KSDRAM_20240125_195507.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:55 BCUread_61568.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 4134 Jan 25 19:55 dumpBCU2KDSP_20240125_195525.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:55 BCUread_61572.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 358366 Jan 25 19:55 dumpBCU2KDSPext1_20240125_195525.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:55 BCUread_61577.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 358477 Jan 25 19:55 dumpBCU2KDSPext2_20240125_195525.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:55 BCUread_61581.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 986141 Jan 25 19:55 dumpBCU2KDSPext3_20240125_195525.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:55 BCUread_61585.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 11962 Jan 25 19:55 dumpBCU2KSRAM_20240125_195525.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:55 BCUread_61623.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 10738 Jan 25 19:55 dumpBCU2KSDRAM_20240125_195525.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:55 BCUread_62074.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 4134 Jan 25 19:55 dumpBCU2KDSP_20240125_195531.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:55 BCUread_62078.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 358366 Jan 25 19:55 dumpBCU2KDSPext1_20240125_195531.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:55 BCUread_62082.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 358477 Jan 25 19:55 dumpBCU2KDSPext2_20240125_195531.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:55 BCUread_62090.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 986141 Jan 25 19:55 dumpBCU2KDSPext3_20240125_195531.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:55 BCUread_62094.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 11962 Jan 25 19:55 dumpBCU2KSRAM_20240125_195531.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:55 BCUread_62098.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 10738 Jan 25 19:55 dumpBCU2KSDRAM_20240125_195531.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:55 BCUread_62565.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 4134 Jan 25 19:55 dumpBCU2KDSP_20240125_195538.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:55 BCUread_62569.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 358366 Jan 25 19:55 dumpBCU2KDSPext1_20240125_195538.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:55 BCUread_62577.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 358477 Jan 25 19:55 dumpBCU2KDSPext2_20240125_195538.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:55 BCUread_62581.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 986141 Jan 25 19:55 dumpBCU2KDSPext3_20240125_195538.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:55 BCUread_62585.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 11962 Jan 25 19:55 dumpBCU2KSRAM_20240125_195538.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:55 BCUread_62589.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 10738 Jan 25 19:55 dumpBCU2KSDRAM_20240125_195538.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:55 BCUread_63224.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 4134 Jan 25 19:55 dumpBCU2KDSP_20240125_195547.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:55 BCUread_63228.202401250000.log

-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:56 BCUread_66521.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 4134 Jan 25 19:56 dumpBCU2KDSP_20240125_195632.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:56 BCUread_66525.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 358366 Jan 25 19:56 dumpBCU2KDSPext1_20240125_195632.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:56 BCUread_66533.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 358479 Jan 25 19:56 dumpBCU2KDSPext2_20240125_195632.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:56 BCUread_66543.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 986141 Jan 25 19:56 dumpBCU2KDSPext3_20240125_195632.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:56 BCUread_66547.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 11962 Jan 25 19:56 dumpBCU2KSRAM_20240125_195632.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:56 BCUread_66551.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 10738 Jan 25 19:56 dumpBCU2KSDRAM_20240125_195632.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:56 BCUread_67219.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 4134 Jan 25 19:56 dumpBCU2KDSP_20240125_195642.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:56 BCUread_67223.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 358366 Jan 25 19:56 dumpBCU2KDSPext1_20240125_195642.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:56 BCUread_67227.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 358479 Jan 25 19:56 dumpBCU2KDSPext2_20240125_195642.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:56 BCUread_67235.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 986141 Jan 25 19:56 dumpBCU2KDSPext3_20240125_195642.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:56 BCUread_67239.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 11962 Jan 25 19:56 dumpBCU2KSRAM_20240125_195642.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 19:56 BCUread_67243.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 10738 Jan 25 19:56 dumpBCU2KSDRAM_20240125_195642.txt

TN:_195729

PSF drift in the pyramid, even when the loop was set to gan zero.

PSF out of the pyramid

gain zero

TN:_200040

bcudump

-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:01 BCUread_87439.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 4134 Jan 25 20:01 dumpBCU2KDSP_20240125_200122.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:01 BCUread_87443.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 358366 Jan 25 20:01 dumpBCU2KDSPext1_20240125_200122.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:01 BCUread_87451.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 358477 Jan 25 20:01 dumpBCU2KDSPext2_20240125_200122.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:01 BCUread_87455.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 986141 Jan 25 20:01 dumpBCU2KDSPext3_20240125_200122.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:01 BCUread_87461.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 11962 Jan 25 20:01 dumpBCU2KSRAM_20240125_200122.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:01 BCUread_87466.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 10738 Jan 25 20:01 dumpBCU2KSDRAM_20240125_200122.txt

slope zero.

TN:_200527

dump.

-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:06 BCUread_107747.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 4137 Jan 25 20:06 dumpBCU2KDSP_20240125_200600.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:06 BCUread_107751.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 358366 Jan 25 20:06 dumpBCU2KDSPext1_20240125_200600.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:06 BCUread_107755.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 358479 Jan 25 20:06 dumpBCU2KDSPext2_20240125_200600.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:06 BCUread_107759.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 986141 Jan 25 20:06 dumpBCU2KDSPext3_20240125_200600.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:06 BCUread_107770.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 11962 Jan 25 20:06 dumpBCU2KSRAM_20240125_200600.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:06 BCUread_107774.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 10738 Jan 25 20:06 dumpBCU2KSDRAM_20240125_200600.txt

-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:07 BCUread_114469.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 4138 Jan 25 20:07 dumpBCU2KDSP_20240125_200737.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:07 BCUread_114473.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 358366 Jan 25 20:07 dumpBCU2KDSPext1_20240125_200737.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:07 BCUread_114481.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 358477 Jan 25 20:07 dumpBCU2KDSPext2_20240125_200737.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:07 BCUread_114486.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 986141 Jan 25 20:07 dumpBCU2KDSPext3_20240125_200737.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:07 BCUread_114490.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 11962 Jan 25 20:07 dumpBCU2KSRAM_20240125_200737.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:07 BCUread_114494.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 10738 Jan 25 20:07 dumpBCU2KSDRAM_20240125_200737.txt

01:08

StopAO from AOS,

Thu Jan 25 20:08:42.550 2024 aos.Stop{FLAO}.complete - Stop{FLAO}[3544]
Thu Jan 25 20:09:11.169 2024 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[3545] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Jan 25 20:09:11.182 2024 aos.info - WFS source set to: FLAOWFS
Thu Jan 25 20:09:11.221 2024 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.6_L040.0_v15.0_ovfreq1700.00_sd3892.fits

close loop+gopt

-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:16 BCUread_149883.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 4142 Jan 25 20:16 dumpBCU2KDSP_20240125_201622.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:16 BCUread_149890.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 364763 Jan 25 20:16 dumpBCU2KDSPext1_20240125_201622.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:16 BCUread_149896.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 364584 Jan 25 20:16 dumpBCU2KDSPext2_20240125_201622.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:16 BCUread_149901.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 986145 Jan 25 20:16 dumpBCU2KDSPext3_20240125_201622.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:16 BCUread_149905.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 11962 Jan 25 20:16 dumpBCU2KSRAM_20240125_201622.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:16 BCUread_149909.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 10738 Jan 25 20:16 dumpBCU2KSDRAM_20240125_201622.txt

TN:_201652

50Hz not well corrected.

optimize again.

better rejection of the 50Hz.

TN:_201857.

-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:19 BCUread_163249.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 4144 Jan 25 20:19 dumpBCU2KDSP_20240125_201933.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:19 BCUread_163253.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 364985 Jan 25 20:19 dumpBCU2KDSPext1_20240125_201933.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:19 BCUread_163261.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 364716 Jan 25 20:19 dumpBCU2KDSPext2_20240125_201933.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:19 BCUread_163265.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 986145 Jan 25 20:19 dumpBCU2KDSPext3_20240125_201933.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:19 BCUread_163269.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 11962 Jan 25 20:19 dumpBCU2KSRAM_20240125_201933.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:19 BCUread_163273.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 10738 Jan 25 20:19 dumpBCU2KSDRAM_20240125_201933.txt

-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:24 BCUread_183826.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 4147 Jan 25 20:24 dumpBCU2KDSP_20240125_202411.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:24 BCUread_183834.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 364418 Jan 25 20:24 dumpBCU2KDSPext1_20240125_202411.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:24 BCUread_183838.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 364937 Jan 25 20:24 dumpBCU2KDSPext2_20240125_202411.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:24 BCUread_183850.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 986145 Jan 25 20:24 dumpBCU2KDSPext3_20240125_202411.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:24 BCUread_183858.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 11962 Jan 25 20:24 dumpBCU2KSRAM_20240125_202411.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:24 BCUread_183862.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 10738 Jan 25 20:24 dumpBCU2KSDRAM_20240125_202411.txt

-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:32 BCUread_25742.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 4152 Jan 25 20:32 dumpBCU2KDSP_20240125_203233.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:32 BCUread_25746.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 364550 Jan 25 20:32 dumpBCU2KDSPext1_20240125_203233.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:32 BCUread_25750.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 364342 Jan 25 20:32 dumpBCU2KDSPext2_20240125_203233.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:32 BCUread_25754.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 986145 Jan 25 20:32 dumpBCU2KDSPext3_20240125_203233.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:32 BCUread_25762.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 11962 Jan 25 20:32 dumpBCU2KSRAM_20240125_203233.txt
-rw-rw-r--. 1 AOeng AOeng 0 Jan 25 20:32 BCUread_25766.202401250000.log
-rw-rw-r--. 1 AOeng AOeng 10738 Jan 25 20:32 dumpBCU2KSDRAM_20240125_203233.txt

02:33

Stop.

240125 21:23:20 std: [0.82541695633235523, 0.87991475141533504, 0.7651675882746003, 0.53617575079956548, 0.50540987725937336, 0.54850078724296936, 0.69237842750591283, 0.52774685115212538]
20240125 21:23:20 Alarm Code: 512 (Pixel means for each octant: 37.9587955182, 38.6418160598, 37.3772152194, 37.4607889823, 37.6771195145, 38.417875817, 37.3280135387, 37.4377637722)
20240125 21:23:23 mean: [52.14810231023101, 53.116031353135305, 51.390013751375143, 51.51062431243124, 51.799708470847087, 52.831207370737069, 51.306658415841589, 51.456735423542348]

WfsArbitrator _21974|ERR| 823|2024-01-25 21:23:20.631018| MAIN > OCAM Bad Frames/Slopes Error events detected during AOSet, code 512
WfsArbitrator_21974|ERR| 824|2024-01-25 21:23:20.631095| MAIN > OCAM bad frame description: Code 512 - Negative Octant
WfsArbitrator_21974|ERR| 825|2024-01-25 21:23:20.631164| MAIN > OCAM suggested action to recover: Verify that OCAM2k is at ambient temperature, then power cycle OCAM2k

only one message. OK

3:00PM

Power off.

Change SW version for night time.

-- JuanCarlosGuerra - 25 Jan 2024
Topic revision: r3 - 26 Jan 2024, JuanCarlosGuerra