Starting 09:45

Brandon compile and install a new environment version.

Currently running: test.20240116.zero-slope-firmware (soul)

Loaded new firmware.

Excel test plan:

https://docs.google.com/spreadsheets/d/1WTxT8pAMRPsS7YU_kSXqWBFzt3kcclbO5mlcD8T0xqw/edit#gid=0

Adsec will be off due to a power switch around 10am.Xianyu is taking care of the Adsecs restart.

Operate

Operate failed.

Bayse stage not power on correctly time out.

Power cycle 24v.

Turnon cube stage

Timeout to connect to the cube stage.

Change the start of cube from the operating process. This was made by Fabio to allow to complete the operation sequence.

There is consistent timeout of the cube stage.



Save dumps.

/home/AOeng/live/source/scripts

> Python bcuDumpScript.py

11:06am

Lights off.



11:08

taking a dump.

Close loop manual gain zero.

11:23

Dump bcu

11:23

Open loop

Change binning setup and check that the bcu goes well.

OK.

Fabio worked the kill all the ocam viewers after the masterdiagnostic is restarted.

Bn4 ok set to bin1.

12:01

Setup argos.

Controller off.

Restart from controller internet connection.



CLOSE LOOP TEST.

aos.info - WFS source set to: FLAOWFS

Tue Jan 16 20:03:17.435 2024 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1700.00_sd3892.fits

Close loop optmize:

1.38,0.33,0.51

TN:20240116_201624

Dump:

-rw-rw-r--. 1 AOeng AOeng 0 Jan 16 20:16 BCUread_101364.202401160000.log

-rw-rw-r--. 1 AOeng AOeng 4098 Jan 16 20:16 dumpBCU2KDSP_20240116_201654.txt

-rw-rw-r--. 1 AOeng AOeng 0 Jan 16 20:16 BCUread_101368.202401160000.log

-rw-rw-r--. 1 AOeng AOeng 364657 Jan 16 20:16 dumpBCU2KDSPext1_20240116_201654.txt

-rw-rw-r--. 1 AOeng AOeng 0 Jan 16 20:16 BCUread_101372.202401160000.log

-rw-rw-r--. 1 AOeng AOeng 364631 Jan 16 20:16 dumpBCU2KDSPext2_20240116_201654.txt

-rw-rw-r--. 1 AOeng AOeng 0 Jan 16 20:16 BCUread_101380.202401160000.log

-rw-rw-r--. 1 AOeng AOeng 986609 Jan 16 20:16 dumpBCU2KDSPext3_20240116_201654.txt

-rw-rw-r--. 1 AOeng AOeng 0 Jan 16 20:16 BCUread_101385.202401160000.log

-rw-rw-r--. 1 AOeng AOeng 11962 Jan 16 20:16 dumpBCU2KSRAM_20240116_201654.txt

-rw-rw-r--. 1 AOeng AOeng 0 Jan 16 20:16 BCUread_101389.202401160000.log

-rw-rw-r--. 1 AOeng AOeng 10738 Jan 16 20:16 dumpBCU2KSDRAM_20240116_201654.txt

Pause.

-rw-rw-r--. 1 AOeng AOeng 0 Jan 16 20:18 BCUread_108335.202401160000.log

-rw-rw-r--. 1 AOeng AOeng 4098 Jan 16 20:18 dumpBCU2KDSP_20240116_201822.txt

-rw-rw-r--. 1 AOeng AOeng 0 Jan 16 20:18 BCUread_108339.202401160000.log

-rw-rw-r--. 1 AOeng AOeng 364578 Jan 16 20:18 dumpBCU2KDSPext1_20240116_201822.txt

-rw-rw-r--. 1 AOeng AOeng 0 Jan 16 20:18 BCUread_108343.202401160000.log

-rw-rw-r--. 1 AOeng AOeng 364471 Jan 16 20:18 dumpBCU2KDSPext2_20240116_201822.txt

-rw-rw-r--. 1 AOeng AOeng 0 Jan 16 20:18 BCUread_108347.202401160000.log

-rw-rw-r--. 1 AOeng AOeng 986609 Jan 16 20:18 dumpBCU2KDSPext3_20240116_201822.txt

-rw-rw-r--. 1 AOeng AOeng 0 Jan 16 20:18 BCUread_108355.202401160000.log

-rw-rw-r--. 1 AOeng AOeng 11962 Jan 16 20:18 dumpBCU2KSRAM_20240116_201822.txt

-rw-rw-r--. 1 AOeng AOeng 0 Jan 16 20:18 BCUread_108359.202401160000.log

-rw-rw-r--. 1 AOeng AOeng 10738 Jan 16 20:18 dumpBCU2KSDRAM_20240116_201822.txt

[AOeng@soul-dxwfs 16]$




Stop

-rw-rw-r--. 1 AOeng AOeng 0 Jan 16 20:19 BCUread_112323.202401160000.log

-rw-rw-r--. 1 AOeng AOeng 4098 Jan 16 20:19 dumpBCU2KDSP_20240116_201910.txt

-rw-rw-r--. 1 AOeng AOeng 0 Jan 16 20:19 BCUread_112327.202401160000.log

-rw-rw-r--. 1 AOeng AOeng 364622 Jan 16 20:19 dumpBCU2KDSPext1_20240116_201910.txt

-rw-rw-r--. 1 AOeng AOeng 0 Jan 16 20:19 BCUread_112335.202401160000.log

-rw-rw-r--. 1 AOeng AOeng 364398 Jan 16 20:19 dumpBCU2KDSPext2_20240116_201910.txt

-rw-rw-r--. 1 AOeng AOeng 0 Jan 16 20:19 BCUread_112342.202401160000.log

-rw-rw-r--. 1 AOeng AOeng 986609 Jan 16 20:19 dumpBCU2KDSPext3_20240116_201910.txt

-rw-rw-r--. 1 AOeng AOeng 0 Jan 16 20:19 BCUread_112346.202401160000.log

-rw-rw-r--. 1 AOeng AOeng 11962 Jan 16 20:19 dumpBCU2KSRAM_20240116_201910.txt

-rw-rw-r--. 1 AOeng AOeng 0 Jan 16 20:19 BCUread_112350.202401160000.log

-rw-rw-r--. 1 AOeng AOeng 10738 Jan 16 20:19 dumpBCU2KSDRAM_20240116_201910.txt

Tue Jan 16 20:18:59.448 2024 aos.Stop{FLAO}.complete - Stop{FLAO}[3724]

Tue Jan 16 20:19:36.143 2024 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[3725] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:14,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

Tue Jan 16 20:19:36.156 2024 aos.info - WFS source set to: FLAOWFS

Tue Jan 16 20:19:36.255 2024 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1700.00_sd3892.fits

TN:_203907

Close loop

-rw-rw-r--. 1 AOeng AOeng 0 Jan 16 20:40 BCUread_58029.202401160000.log

-rw-rw-r--. 1 AOeng AOeng 4098 Jan 16 20:40 dumpBCU2KDSP_20240116_204053.txt

-rw-rw-r--. 1 AOeng AOeng 0 Jan 16 20:40 BCUread_58034.202401160000.log

-rw-rw-r--. 1 AOeng AOeng 364618 Jan 16 20:40 dumpBCU2KDSPext1_20240116_204053.txt

-rw-rw-r--. 1 AOeng AOeng 0 Jan 16 20:40 BCUread_58052.202401160000.log

-rw-rw-r--. 1 AOeng AOeng 364534 Jan 16 20:40 dumpBCU2KDSPext2_20240116_204053.txt

-rw-rw-r--. 1 AOeng AOeng 0 Jan 16 20:40 BCUread_58069.202401160000.log

-rw-rw-r--. 1 AOeng AOeng 986609 Jan 16 20:40 dumpBCU2KDSPext3_20240116_204053.txt

-rw-rw-r--. 1 AOeng AOeng 0 Jan 16 20:40 BCUread_58092.202401160000.log

-rw-rw-r--. 1 AOeng AOeng 11962 Jan 16 20:40 dumpBCU2KSRAM_20240116_204053.txt

-rw-rw-r--. 1 AOeng AOeng 0 Jan 16 20:40 BCUread_58100.202401160000.log

-rw-rw-r--. 1 AOeng AOeng 10738 Jan 16 20:40 dumpBCU2KSDRAM_20240116_204053.txt

stopAO

-rw-rw-r--. 1 AOeng AOeng 0 Jan 16 20:41 BCUread_61859.202401160000.log

-rw-rw-r--. 1 AOeng AOeng 4099 Jan 16 20:41 dumpBCU2KDSP_20240116_204139.txt

-rw-rw-r--. 1 AOeng AOeng 0 Jan 16 20:41 BCUread_61863.202401160000.log

-rw-rw-r--. 1 AOeng AOeng 364622 Jan 16 20:41 dumpBCU2KDSPext1_20240116_204139.txt

-rw-rw-r--. 1 AOeng AOeng 0 Jan 16 20:41 BCUread_61867.202401160000.log

-rw-rw-r--. 1 AOeng AOeng 364447 Jan 16 20:41 dumpBCU2KDSPext2_20240116_204139.txt

-rw-rw-r--. 1 AOeng AOeng 0 Jan 16 20:41 BCUread_61871.202401160000.log

-rw-rw-r--. 1 AOeng AOeng 986609 Jan 16 20:41 dumpBCU2KDSPext3_20240116_204139.txt

-rw-rw-r--. 1 AOeng AOeng 0 Jan 16 20:41 BCUread_61875.202401160000.log

-rw-rw-r--. 1 AOeng AOeng 11962 Jan 16 20:41 dumpBCU2KSRAM_20240116_204139.txt

-rw-rw-r--. 1 AOeng AOeng 0 Jan 16 20:41 BCUread_61879.202401160000.log

-rw-rw-r--. 1 AOeng AOeng 10738 Jan 16 20:41 dumpBCU2KSDRAM_20240116_204139.txt



1:45 stop

Switch versions.

[AOeng@soul-dxwfs scripts]$ use_soul

Usage: use_soul [version]

Currently running: test.20231115.bad-frames-phase-1 (soul

Check power on.

New steps.

37.115766| MAIN > Waiting for network connection (right box)

WfsArbitrator_108818|INF| 73|2024-01-16 20:59:38.996671| MAIN > Turning on AUX5V_POWER

WfsArbitrator_108818|INF| 74|2024-01-16 20:59:39.912956| MAIN > Turning on COP_POWER

WfsArbitrator_108818|INF| 75|2024-01-16 20:59:42.181273| MAIN > Turning on PI_POWER

WfsArbitrator_108818|INF| 76|2024-01-16 20:59:43.998773| MAIN > Power Cycle of 24V main power

WfsArbitrator_108818|INF| 77|2024-01-16 20:59:43.998814| MAIN > Turning off main

WfsArbitrator_108818|INF| 78|2024-01-16 20:59:55.618133| MAIN > Turning on main

Ocam not ilive

lopeCompCtrl2K_108367|INF| 279|2024-01-16 21:07:10.180414| MAIN > Ccd39 current binning to 1

SlopeCompCtrl2K_108367|INF| 280|2024-01-16 21:07:10.206732| MAIN > Setting tomography gain to 1256.000000

SlopeCompCtrl2K_108367|INF| 281|2024-01-16 21:07:10.206764| MAIN > Disabling ocam interface

SlopeCompCtrl2K_108367|INF| 282|2024-01-16 21:07:10.207538| MAIN > Ocam interface Disabled

SlopeCompCtrl2K_108367|INF| 283|2024-01-16 21:07:10.208214| MAIN > DSP stopped

SlopeCompCtrl2K_108367|INF| 284|2024-01-16 21:07:10.314578| MAIN > Tomography gain set to 1256.000000

SlopeCompCtrl2K_108367|INF| 285|2024-01-16 21:07:11.424967| MAIN > Setting pixel decimation to 3

SlopeCompCtrl2K_108367|INF| 286|2024-01-16 21:07:22.223514| MAIN > Frame burst started

SlopeCompCtrl2K_108367|INF| 286|2024-01-16 21:07:22.223514| MAIN > .

Change binning didn;t solve it.

Restart masterdiagnostics

Not solve

Power cycle bcu2k and reset bin.

Ocam live + one bad quadrant.

tn:_211226

01:40PM

Power off.

change version to night operations.

Test power on.

OK