Staff:

LBTO: Brandon, Juan CArlos

Observer

Details.

test plan:

https://docs.google.com/spreadsheets/d/1WTxT8pAMRPsS7YU_kSXqWBFzt3kcclbO5mlcD8T0xqw/edit#gid=2138720598

Power on WFS

12:40

TEst the badframe task and wfsarbitrator logging.

Likely we had a triangle feature and two bad quadrants, so the errors were triggered.

20240126 21:30:30 std: [0.98930677561921987, 1.0635129196238877, 80.909145783171724, 1.214635521433423, 1.1828022409020675, 81.82955398620588, 0.85308183257556114, 0.62706317758942209]
20240126 21:30:33 mean: [45.17841111111111, 45.929924999999997, 53.380713888888884, 44.706147222222214, 44.709941666666666, 52.725541666666679, 44.274591666666666, 44.536011111111108]
20240126 21:30:33 rms: [12.604675505802897, 14.969455186845293, 15.273470172932925, 12.102920026351198, 12.090101594809838, 15.345122218941217, 15.715761218874663, 11.883673294971711]
20240126 21:30:33 std: [0.98636457573356995, 1.0616419985965206, 89.053879246635546, 1.2118190585722779, 1.2060111284250226, 85.245929239527584, 0.86047732306005187, 0.62286014573761039]
20240126 21:30:36 mean: [48.948422222222213, 49.746188888888895, 57.359322222222218, 48.430208333333319, 48.43118611111111, 57.343594444444449, 47.955644444444452, 48.234669444444442]
20240126 21:30:36 rms: [13.657392771488922, 16.183289769741521, 16.590224591909205, 13.074890432849614, 13.056613321403715, 16.613467240037011, 17.126813003653524, 12.934392123948276]
20240126 21:30:36 std: [1.0680375347296329, 1.1510637528155607, 93.84596264170294, 1.3432796102555924, 1.3145874880875308, 93.814684412247445, 0.93609657696300241, 0.67859589003205167]
20240126 21:30:38 mean: [45.176752777777786, 45.927588888888877, 53.473413888888878, 44.699844444444444, 44.706652777777769, 52.651655555555564, 44.262797222222225, 44.538391666666669]
20240126 21:30:38 rms: [12.586205142169227, 14.957147673924112, 15.453724273547873, 12.121272398997219, 12.085531138194094, 15.317143671997915, 15.741465526295833, 11.851001293595168]
20240126 21:30:38 std: [0.98522671048180444, 1.0604039928298459, 89.485270528976855, 1.2329671193594955, 1.229754294492974, 84.532157814383027, 0.85211691445923476, 0.62224381758129155]
20240126 21:30:41 mean: [45.185816666666668, 45.92263333333333, 53.072449999999996, 44.718727777777779, 44.719558333333332, 52.738288888888889, 44.252322222222219, 44.543736111111109]
20240126 21:30:41 rms: [12.621279993997053, 14.941408346336241, 15.381039196248482, 12.07610270318497, 12.111889496019398, 15.347392104771183, 15.886032901398583, 11.856491214319563]
20240126 21:30:41 std: [0.98342678246400794, 1.0627904172698772, 87.277276544583984, 1.2368693999094778, 1.2172213690143854, 85.667425245218197, 0.85961660662498429, 0.62277671149295655]
...

WfsArbitrator _75565|ERR| 568|2024-01-26 20:42:10.459812| MAIN > OCAM Bad Frames/Slopes Error events detected during AOSet, code 512
WfsArbitrator_75565|ERR| 569|2024-01-26 20:42:10.459886| MAIN > OCAM bad frame description: Code 512 - Negative Octant
WfsArbitrator_75565|ERR| 570|2024-01-26 20:42:10.459935| MAIN > OCAM suggested action to recover: Verify that OCAM2k is at ambient temperature, then power cycle OCAM2k
WfsArbitrator_75565|WAR| 571|2024-01-26 20:52:04.341973| MAIN > OCAM Bad Frames/Slopes Warning events detected during AOSet, code 32
WfsArbitrator_75565|WAR| 572|2024-01-26 20:52:04.342027| MAIN > OCAM bad frame description: Code 32 - High RMS Slopes
WfsArbitrator_75565|WAR| 573|2024-01-26 20:52:04.342051| MAIN > OCAM suggested action to recover: No Action required; check Ao loop performances
WfsArbitrator_75565|ERR| 574|2024-01-26 21:05:35.639904| MAIN > OCAM Bad Frames/Slopes Error events detected during AOSet, code 512
WfsArbitrator_75565|ERR| 575|2024-01-26 21:05:35.639988| MAIN > OCAM bad frame description: Code 512 - Negative Octant
WfsArbitrator_75565|ERR| 576|2024-01-26 21:05:35.640021| MAIN > OCAM suggested action to recover: Verify that OCAM2k is at ambient temperature, then power cycle OCAM2k
WfsArbitrator_75565|WAR| 577|2024-01-26 21:10:30.992799| MAIN > OCAM Bad Frames/Slopes Warning events detected during AOSet, code 32
WfsArbitrator_75565|WAR| 578|2024-01-26 21:10:30.992859| MAIN > OCAM bad frame description: Code 32 - High RMS Slopes
WfsArbitrator_75565|WAR| 579|2024-01-26 21:10:30.992880| MAIN > OCAM suggested action to recover: No Action required; check Ao loop performances
WfsArbitrator_75565|ERR| 580|2024-01-26 21:20:50.775726| MAIN > OCAM Bad Frames/Slopes Error events detected during AOSet, code 512
WfsArbitrator_75565|ERR| 581|2024-01-26 21:20:50.775797| MAIN > OCAM bad frame description: Code 512 - Negative Octant
WfsArbitrator_75565|ERR| 582|2024-01-26 21:20:50.775838| MAIN > OCAM suggested action to recover: Verify that OCAM2k is at ambient temperature, then power cycle OCAM2

TN:20240126_212948

power off

2:27PM

-- JuanCarlosGuerra - 26 Jan 2024
Topic revision: r1 - 26 Jan 2024, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback