Staff:

LBTO: David, Andrew, Jared, Juan Carlos.

Observer: Remote INAF (shark-nir team)

Forecast.

forecast0_20231231.png

forecast1_20231231.png

Details.

Power on WFS.

Sun Dec 31 22:16:49.906 2023 aos.info - Notification requested for variable: wfsarb.L.MSG@M_LBTIWFS
  • OCAM ok
  • ccd47 OK
  • take ccd47 dark
  • saved frames:20231231-222410

04:22

Getting covered by clouds.

Running both LMIR cam and Shark-Nir.

05:32

Opening

clouds.

Collimation star.

Mon Jan 1 00:38:41.841 2024 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[2340] (aomode:ACE-AO,focst:bentGregorianCenter,instr:SHARK,wfs:LBTIWFS,sox:0[0],soy:0,rox:-0.101114[-0.101114],roy:8.49389e-08,mag:2.23,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan).

Found star in CCD47

IE=9, CA=39, temp=

Mon Jan 1 00:53:38.393 2024 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[2342] (aomode:ACE-AO,focst:bentGregorianCenter,instr:SHARK,wfs:LBTIWFS,sox:0[0],soy:0,rox:-0.118766[-0.118766],roy:4.91838e-09,mag:7.49,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

save TN:20231231_010302.

seeing 2.1

optmize manual.

seeing 1.5

TN:_010910,

modalSR:76,

sloperms 2.1

06:16

variable seeing 1.5- 2"

TN:_011615

06:18

seeing 2.1"

lower ho2 one click to have loop not skipping.->TN:_011925

seeing too variable and bad, jump to 2.5 SX loop opened,

Change target.,

close binary.0.07arcsec confirm looking at the lmir cam.

TN:013735.

change target not good for shark.

To check the gopt, the signal was very low.

seeing 2.2

loop open.

Mon Jan 1 01:43:40.443 2024 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[2352] (aomode:ACE-AO,focst:bentGregorianCenter,instr:SHARK,wfs:LBTIWFS,sox:0[0],soy:0,rox:-0.117696[-0.117696],roy:-2.32331e-07,mag:10.45,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

seeing 2

TN:_015239

06:58

variable seeing 1.8-2

TN:_015932

07:28

clouds passing

modalSR:55

variable seeing 1.5 to 2

TN:-023618

seeing 1.4 best perform 60% sloperms 1.9,gopt sig 0.19

seeing 1.4 best perf 68% slope rms 1.7,goptsig:0.23

TN:_024303

seeing 1.4, best perf 68, slperms1.8, gopt sig 02.

seeig 1.5

TN:_024728,_024525

08:00

loop open skip frames seeig up ot 1.9"

oprtimize with seeing 1.7

TN:_030427

modal55, sloperms2.4,gopt sig 0.15

08:19

seeing 1.5,slperms2.2,goptsig 0.15, modelSR60

TN:_031812

seign 1.5,sloperms1.7, gopt sig 0.22 modal SR70

TN:_032003,goptgain:1.25,0.09,0.12

TN:_032032

08:31

seeing 1.15,sloperms1.8, goptsig 0.23 modal 75

TN:_033117

TN:_035622

09:36

seeing 1.3"

TN:_043615.

09:59

SEEING 1.63, SLOPERMS3.2,GROP SIG=0.10

TN:_045911

Mon Jan 1 05:28:59.121 2024 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[2362] (aomode:ACE-AO,focst:bentGregorianCenter,instr:SHARK,wfs:LBTIWFS,sox:0[0],soy:0,rox:-0.134658[-0.134658],roy:-9.45853e-09,mag:9.61,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

seeng 1.2

TN:_054755.

seeing 1.3, sloperms=2.5, gopt sig:0.17

TN:_055013

11:11

loop opened due to skip frames

Mon Jan 1 06:08:57.004 2024 aos.info - TTF Offload request (FLAO) Z: 0.700964 0.864855 2.39616e-05
Mon Jan 1 06:08:59.353 2024 aos.info - AO loop opened, Sound=leftAOOPENED.wav
Mon Jan 1 06:08:59.353 2024 aos.info - FLAO Alert [ code:177] SkipFrame

reclosed optimized.

seeing 1.4

TN:_061253

seeing varable 1.7 to 2. start to skip frame.

gopt: 0.32,0.19,0.16

one click down ho2->0.13

loop stable.

gopt signal to 0.1,0.09.

EL 82

12:32am

skpping frame 30%. reduced one click the HO2 rate 10-15%

loop opened.

reclose,optimize, gopt

TN:_073403

modal sr 40%, sloperms 5, gopt sig 0.09

gopt :0.20,0.17,0.11

seeing 3.4,sloperms 5.5, gopt sig0.09

Tn:_075037

seeing ?, sloperms:2.5, modal sr 60 gopt sig0.15

Mon Jan 1 08:57:32.561 2024 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[2367] (aomode:ACE-AO,focst:bentGregorianCenter,instr:SHARK,wfs:LBTIWFS,sox:0[0],soy:0,rox:-0.0835345[-0.0835345],roy:6.21549e-08,mag:7.58,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

IE,14,CA19, az=, el=

gopt:1.24,0.24,0.22

seeing 1.39

3:30

1.17,modalsr,sloperms1.5,gopt sig0.26

TN:_103044

modal SR80, sloperms1.7,gopt sig:0.22,freq 1700

TN:_092542

Mon Jan 1 11:17:39.773 2024 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[2373] (aomode:ACE-AO,focst:bentGregorianCenter,instr:SHARK,wfs:LBTIWFS,sox:0[0],soy:0,rox:-0.166817[-0.166817],roy:-1.21461e-07,mag:9.53,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Jan 1 11:17:39.802 2024 aos.info - WFS source set to: LBTIWFS

IE24, CA5, EL=53

seeing.1.25,sloperms 2.5. modalSR75,gopt sig,0.20, freq 900

TN:_112941.

Chamber temperature -4.58

04:51

seeing 1.5,sloperm2.7 modalsr67 gopt sg0.16

TN:_115127

05:05

seeing 1.75, sloperms 3.2,modalsr60, gopt sig0.11

TN:_120551

05:18

loop opened.

12:18:39.689073| MAIN > Camera lens tracking: AdSec is skipping frames, camera lens not moving
WfsArbitrator_24632|INF| 7354|2024-01-01 12:18:39.872346| WFS > Executing stopLoop...

12:18:36.854711| MAIN > Skip frame detected! (41.75% of frames skipped.)
adsecarb.L.202401010002.log:AdSecArbitrator_80351|WAR| 13850|2024-01-01 12:18:38.866105| MAIN > Skip frame detected! (108.64% of frames skipped.)

reclosed/optimize/gopt.

TN:_122330

sloperms;1.7 seeng1.51 , modalsr77, goptsig0.23 freq 900

TN:_125500

06:19

seeing 1.2, sloperms1.5,modalsr80, goptsig0.26

TN:_131924

06:30

Mon Jan 1 13:30:44.090 2024 aos.info - FLAO Alert [ code:0] Error
Mon Jan 1 13:30:44.555 2024 aos.info - Updated variable adamhousekeeper.L.COIL_STATUS: 0
Mon Jan 1 13:30:44.821 2024 aos.Stop{FLAO}.started - Stop{FLAO}[2378] (msg:Preset canceled)

both adsec to Failure state.
  • Power bump.
  • OCAm set safe.
  • adsc_stop/start.
  • Check flat OK.
  • Rest SX/DX.

-- JuanCarlosGuerra - 31 Dec 2023
Topic revision: r5 - 01 Jan 2024, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback