Staff:

LBTO: Steve, Justin, Juan CArlos

Observer: Queue

Forecast.

forecast0_20231219.png

Details.

04:10

Power on SX/DX.

SX.

Ocam OK

Dx

Ocam ok

cloud cover.

Stay closed.

WfsArbitrator _59503|ERR| 44|2023-12-19 23:53:21.059621| MAIN > OCAM Bad Frames/Slopes Error events detected during Operating, code 64
WfsArbitrator_59503|ERR| 45|2023-12-19 23:53:21.059672| MAIN > OCAM bad frame description: Code 64 - Ocam Flame: noise pattern compromise pixel data
WfsArbitrator_59503|ERR| 46|2023-12-19 23:53:21.059701| MAIN > OCAM suggested action to recover: Check OCAM viewer to confirm; if required, change Bin back and forth via WFS control GUI
WfsArbitrator_59503|ERR| 47|2023-12-19 23:53:50.558111| MAIN > OCAM Bad Frames/Slopes Error events detected during Operating, code 64
WfsArbitrator_59503|ERR| 48|2023-12-19 23:53:50.558136| MAIN > OCAM bad frame description: Code 64 - Ocam Flame: noise pattern compromise pixel data
WfsArbitrator_59503|ERR| 49|2023-12-19 23:53:50.558158| MAIN > OCAM suggested action to recover: Check OCAM viewer to confirm; if required, change Bin back and forth via WFS

0231219 23:53:21 mean: [276.76093611111116, 189.36631388888887, 187.79140277777785, 267.62274166666663, 271.45925833333325, 192.76228888888886, 188.23001944444439, 268.80370555555555]
20231219 23:53:21 rms: [77.583302745327103, 58.081543712779521, 59.47142889223953, 70.758043856087099, 90.737992374090069, 65.681568893076332, 59.318626537065235, 72.347184076019346]
20231219 23:53:21 std: [480.3499765617313, 5.5619205007535593, 4.5229048397925053, 452.01231606432628, 485.34416208282067, 26.48403209436086, 5.1850673893759742, 456.63574629730306]
20231219 23:53:21 Alarm Code: 64

20231219 23:53:50 mean: [309.36805555555571, 189.77181111111111, 188.14386388888889, 300.3350638888889, 305.60068611111109, 198.93706388888887, 192.41665555555556, 303.29741111111116]
20231219 23:53:50 rms: [79.939606519580039, 59.255867933961817, 59.869739087304623, 74.476211024266277, 90.811209659993452, 66.763793183143264, 62.664841611027761, 76.931627281425733]
20231219 23:53:50 std: [571.19180435250109, 6.0045771948059317, 4.7639577576687744, 549.83909025484877, 579.46051524906295, 40.031541540382236, 20.790979657478115, 551.21496464972051]
20231219 23:53:50 Alarm Code: 64

DX

Code 32.

20231220 00:27:34 mean: [198.34480000000002, 196.05407222222229, 194.32598333333334, 195.52318333333344, 197.07501388888886, 194.64054444444434, 193.89506666666668, 195.35115000000005]
20231220 00:27:34 rms: [81.294356597091664, 76.039227888995498, 72.823978199565815, 74.208802441771624, 78.057352929493035, 75.458158490594002, 71.181208192595449, 73.588452458011432]
20231220 00:27:34 std: [5.2021585290581163, 6.4348520118810537, 6.2751429002372712, 4.7390410955776137, 4.4194672524122378, 7.2883791281153227, 5.7325279737272901, 4.1259047956391122]
20231220 00:27:34 Alarm Code: 32

TN:20231220_002858

06:09

Opening a gap in the clouds.

SH 1.9"

center pupils failed both sides same time. AdsecSX /DX went into failure.

SX:
  • WfsArbitrator _154861|INF| 105|2023-12-20 01:25:29.678985| COMMANDHANDLER > Command centerPupils (code 2039) successfully completed
  • WfsArbitrator _154861|INF| 106|2023-12-20 01:25:29.679286| WFS > Executing closeLoop...
  • WfsArbitrator _154861|INF| 107|2023-12-20 01:25:29.679330| WFS > Python command: WfsArbScripts.closeLoop(self, sensor = 'FLAOWFS', instr = 'LUCIFER')
  • WfsArbitrator _154861|INF| 108|2023-12-20 01:25:29.683283| WFS > Command returns success .
  • WfsArbitrator _154861|INF| 109|2023-12-20 01:25:29.683318| MASTDIAGN > Setting master diagnostic in closed loop mode
  • WfsArbitrator _154861|INF| 110|2023-12-20 01:26:05.764920| WFS > Executing stopLoop...
  • WfsArbitrator _154861|INF| 111|2023-12-20 01:26:05.764998| WFS > Python command: WfsArbScripts.stopLoop(self, sensor = 'FLAOWFS', instr = 'LUCIFER')
  • AOS:
  • python_26399 |DEB| 484|2023-12-20 01:25:10.998775| MAIN > UPD progr. 30 - Setting parameters for camera lens centering
  • python_26399 |DEB| 485|2023-12-20 01:25:12.085630| MAIN > UPD progr. 40 - Centering camera lens
  • python_26399 |DEB| 486|2023-12-20 01:25:29.688342| MAIN > Camera lens centering may require up to 184 seconds
  • python_26399 |ERR| 487|2023-12-20 01:25:34.910764| MAIN > Alert from AdSec [0] - Error

AdSecArbitrator _26370|INF| 846|2023-12-20 01:25:29.687142| COMMANDHANDLER > Command TTOffload (code 2029) successfully completed
AdSecArbitrator_26370|ERR| 847|2023-12-20 01:25:34.910297| ALERTHANDLER > Received an ERROR alert! Forcing Failure state.
AdSecArbitrator_26370|ERR| 848|2023-12-20 01:25:34.910363| ALERTHANDLER > Alert message: COILS DISABLED from fastdiagn.L.

fast.

fastdiagn.L.202312200000.log:fastdiagn_26316 |WAR| 3484038|2023-12-20 01:25:32.882523| MAIN > Timeout - Will emergencyReact next loop [FastDiagnostic.cpp:1090]
fastdiagn.L.202312200000.log:fastdiagn_26316 |WAR| 3484039|2023-12-20 01:25:34.883401| MAIN > Timeout - Will emergencyReact now [FastDiagnostic.cpp:1085]
fastdiagn.L.202312200000.log:fastdiagn_26316 |ERR| 3484040|2023-12-20 01:25:34.883435| FUNCTEMERGENCYSTOP > emergencyReact = 1 [Funct.cpp:95]

DX:
  • sArbitrator_59503|INF| 394|2023-12-20 01:25:14.895634| MAIN > Received cmd: centerPupils()
  • WfsArbitrator _59503|INF| 395|2023-12-20 01:25:29.452051| MASTDIAGN > Setting master diagnostic in closed loop mode
  • WfsArbitrator _59503|INF| 396|2023-12-20 01:26:07.558829| MASTDIAGN > Setting master diagnostic in open loop mode
  • AOS:
  • ython_48947 |DEB| 197|2023-12-20 01:25:29.477860| MAIN > Camera lens centering may require up to 184 seconds
  • python_48947 |INF| 198|2023-12-20 01:25:39.537529| MAIN > ... 1 equal lines suppressed
  • python_48947 |WAR| 199|2023-12-20 01:25:39.537578| MAIN > Alert from AdSec [0] - [Unexpected alert] - FAILED ACTUATOR
AdSecArbitrator _48835|WAR| 233|2023-12-20 01:25:34.583673| MAIN > Skip frame detected! (45.00% of frames skipped.)
AdSecArbitrator_48835|ERR| 234|2023-12-20 01:25:39.537083| ALERTHANDLER > Received alert: actuator 0 is not working correctly (from fastdiagn.R)

fast.

fastdiagn.R.202312200000.log:fastdiagn_48720 |INF| 15333300|2023-12-20 01:25:39.536746| NOTIFYACTFAIL > Failing actuator detected N. 0 Value: 0 on position (CHDISTAVERAGE-0000)
fastdiagn.R.202312200000.log:fastdiagn_48720 |INF| 15333301|2023-12-20 01:25:39.536836| NOTIFYACTFAIL > [FunctNotifyFailingActuator] Alert to AdSec Arbitrator succesfully sent! [Funct.cpp:235]
fastdiagn.R.202312200000.log:fastdiagn_48720 |WAR| 15333302|2023-12-20 01:25:39.536881| FUNCTWARNING > FunctWarning CHDISTAVERAGE-0023 0
fastdiagn.R.202312200000.log:fastdiagn_48720 |ERR| 15333303|2023-12-20 01:25:39.538259| FUNCTALARM > FunctAlarm MODES-0000 -0.390898

adsec stop/start.

wfs-stop/start

WfsArbitrator _108755|WAR| 1626|2023-12-20 01:59:39.291998| MAIN > OCAM bad frame description: Code 128 - Noisy Octants: Pixel RMS in external octants is high
WfsArbitrator_108755|WAR| 1627|2023-12-20 01:59:39.292005| MAIN > OCAM suggested action to recover: No action required; no impact on performance is expected
WfsArbitrator_108755|WAR| 1628|2023-12-20 01:59:41.352248| MAIN > OCAM Bad Frames/Slopes Warning events detected during LoopClosed, code 128
WfsArbitrator_108755|WAR| 1629|2023-12-20 01:59:41.352269| MAIN > OCAM bad frame description: Code 128 - Noisy Octants: Pixel RMS in external octants is high
WfsArbitrator_108755|WAR| 1630|2023-12-20 01:59:41.352281| MAIN > OCAM suggested action to recover: No action required; no impact on performance is expected

20231220 01:59:53 mean: [229.57222222222225, 231.69840000000005, 215.36837777777771, 241.84753333333342, 234.05179999999993, 238.25468888888889, 232.42615555555548, 239.26784444444442]
20231220 01:59:53 rms: [97.042594583082135, 83.327092611113301, 98.439284559397024, 80.21067489127293, 94.380028585878861, 87.278079650581716, 83.251604920597842, 81.095058772021389]
20231220 01:59:53 std: [37.791017943128026, 15.120251725872027, 9.9726242012471484, 31.490478556342119, 31.348556497796871, 12.56598961787744, 10.150358423079769, 33.14997257669939]
20231220 01:59:53 Alarm Code: 128
20231220 01:59:55 mean: [229.00226666666669, 231.70375555555555, 215.24275555555553, 241.87406666666678, 234.25435555555555, 238.53344444444443, 232.5464666666667, 239.42900000000006]
20231220 01:59:55 rms: [97.279259810658957, 83.929324312838531, 98.057155237759162, 79.972888701398119, 94.314741531047915, 87.777922221735494, 83.199010187493855, 81.467407258465514]
20231220 01:59:55 std: [36.357474419490941, 15.190725765491763, 9.9090547952738941, 31.20762856036643, 31.152941644848077, 12.653754580397536, 10.086973327507193, 33.591232145297496]
20231220 01:59:55 Alarm Code: 128
20231220 01:59:57 mean: [229.03993333333332, 231.69937777777773, 215.37495555555557, 241.89039999999989, 232.94280000000003, 238.36104444444442, 232.50339999999997, 238.53857777777768]
20231220 01:59:57 rms: [97.186577515791356, 84.032132603122008, 97.824160001457955, 80.2540172450325, 94.527942885827301, 87.712124328041085, 83.379728146823439, 81.357592486322702]
20231220 01:59:57 std: [36.82944146606026, 15.13924476642719, 9.9525915305027493, 31.253323207050865, 28.434942542511994, 12.568647814798014, 10.088653324170814, 31.314332007116779]
20231220 01:59:57 Alarm Code: 128

TN SX and DX.

SX: 20231220_015523

dx:_015301,015527

02:18UT
  • Open loop SX due to skip frames.
  • AdSecArbitrator_127231|INF| 387|2023-12-20 02:08:25.237028| COMMANDHANDLER > Command TTOffload (code 2029) successfully completed
  • AdSecArbitrator_127231|WAR| 388|2023-12-20 02:09:43.319199| MAIN > Skip frame detected! (350.00% of frames skipped.)
Reclosed.

didn not work. because the guider was driving the star.
  • - Stop guiding.
  • - set low gain TT0.5,
  • - close loop from WFS control.
  • It should grab the star and to have the four pupils illuminated.
  • Apply ho1 to 0.1,
  • apply TT hgher to get a better corrcton nof higher order.
  • At tha moment the guider is open.
  • to sync with the AO arbitrator.
  • oipen loop from WFScontrol
  • FLAOG gui. Reclosed loop
  • Restablish the gains.
  • The AO arbitrator should be sync and offset will be OK.
07:39

close shutters. clouds covering...

12:50

still closed.

ocam DX overillumination ?

TN saved:20231220_075009

02:14

No changes to open. Still cloudy. Justin released the AO for tonight

power off WFS

IT:

Update IT related to timeouts of the fast. IT#8539

New IT related to Mode 0. IT#9022

-- JuanCarlosGuerra - 19 Dec 2023
Topic revision: r5 - 22 Dec 2023, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.