Staff:

LBTO: Alessandro, Mark, Juan Carlos, Leroy.

Details.

Bayside stage Z coupling loose.

Alessandro fixing the coupling

09:18

load boardsetup internal2

with this the pupils are vignetted, it will enough for a rough rotation approach.

rotation_pupils_boardsetup.png

pupils down.

09:23

deploy argos cal unit.

Alesssandro working on the coupling of Z stage.

both screws tight.

09:44

starting to work in the rotation

first approximation to center.

really good.

Moving to get the pupil with the argos.

Freq200,

TN:20231211_171447.

Loop closed for center pupils good.

-171958

_173607 (loop closed 0.1)

with this image a rotation of 0.7

change the pupilcheckocam2.conf to separate (indivial pupl reading)

first_attempt.png

10:41

tight screws.

light on

ocam EMgain 1, freq 1000

_171818(10K)

back.

clkose loop 0.1

TN:_175818

rotation 1.2

untight and move

11:12

check

close loop TT

-181740

0.1HO1

_182203 (20K)

image 6

rotat 0.9

-182636

image 7, rot 0.84

Move_leverapprox2mm.png

11:32

ocam save EMg=1, freq=1000

light on

another change ~3mm same direction.

untight and move,

11:37

lightoff

TT

_184210

HO1

_184427

rot 0.52

11:51

light on

Ocam safe.

move same amount and direction ~3mm.

12:04

light off

ho1

_191112

error larger one pxel off. clear in the images

lunch break

12:44

lights on

ocam safe

adjustment

light off

01:03

close loop.

Opne loop 20K

TN:_200238,_200550,_2008112134

CL 0.1

201129,_201349,_201606,_201927,_202134,_202445

open loop

TN:_202720

Check loop closed.

not disturbance

optimized not issues

_204557,_204611,_204634

sloperms 0.7

Mon Dec 11 20:48:46.235 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[884] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Dec 11 20:48:46.250 2023 aos.info - WFS source set to: FLAOWFS
Mon Dec 11 20:48:46.283 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1700.00_sd3892.fits

optimize

0.92,.32,0.44

TN:_205832,_205954,_210022

sloperms 0.92

TN+luci: -210210,_210323,210433,_

tn+luci+ncpa:_210539,_210641.

dark

Pause/resume.

Mon Dec 11 21:09:48.183 2023 aos.Resume{FLAO}.complete - Resume{FLAO}[863]
Mon Dec 11 21:09:48.705 2023 aos.info - TTF offload: previous 2 requests ignored
Mon Dec 11 21:09:48.722 2023 aos.info - TTF Offload request (FLAO) Z: -0.0156929 0.213458 0.00352003
Mon Dec 11 21:09:52.421 2023 aos.info - TTF offload command end
Mon Dec 11 21:09:52.995 2023 aos.info - TTF offload: previous 3 requests ignored
Mon Dec 11 21:09:53.013 2023 aos.info - TTF Offload request (FLAO) Z: -0.874696 1.12303 0.0052599
Mon Dec 11 21:09:55.595 2023 aos.info - AO loop opened, Sound=rightAOOPENED.wav
Mon Dec 11 21:09:55.595 2023 aos.info - FLAO Alert [ code:177] SkipFrame
Mon Dec 11 21:09:55.916 2023 aos.info - TTF offload command end

reclosed.

optmize:1.5,0.28,0.44

TN+luci:211319,_211553

TN+luci+ncpa:_211647,_211902

modalplot_cl_ngle.png

TT_cl_angle.png

SR_cl_angle.png

pause/resume.

OK

Mon Dec 11 21:19:18.895 2023 aos.info - TTF offload: previous 2 requests ignored
Mon Dec 11 21:19:18.907 2023 aos.info - TTF Offload request (FLAO) Z: 0.0460265 -0.037747 2.34788e-05
Mon Dec 11 21:19:21.583 2023 aos.info - TTF offload command end
Mon Dec 11 21:19:21.898 2023 aos.info - TTF offload: previous 2 requests ignored
Mon Dec 11 21:19:21.910 2023 aos.info - TTF Offload request (FLAO) Z: 0.0342952 -0.0313926 -3.80571e-05
Mon Dec 11 21:19:24.571 2023 aos.info - TTF offload command end
Mon Dec 11 21:19:24.908 2023 aos.info - TTF offload: previous 1 requests ignored
Mon Dec 11 21:19:24.926 2023 aos.info - TTF Offload request (FLAO) Z: -0.0504536 0.00228956 -6.95581e-05
Mon Dec 11 21:19:27.584 2023 aos.info - TTF offload command end
Mon Dec 11 21:19:27.912 2023 aos.info - TTF offload: previous 2 requests ignored
Mon Dec 11 21:19:27.926 2023 aos.info - TTF Offload request (FLAO) Z: -0.0658526 0.00446348 -0.000109897
Mon Dec 11 21:19:30.596 2023 aos.info - TTF offload command end
Mon Dec 11 21:19:56.216 2023 aos.Pause{FLAO}.started - Pause{FLAO}[863]
Mon Dec 11 21:19:56.645 2023 aos.info - AO loop closed
Mon Dec 11 21:19:56.645 2023 aos.Pause{FLAO}.complete - Pause{FLAO}[863]
Mon Dec 11 21:20:06.337 2023 aos.Resume{FLAO}.started - Resume{FLAO}[863]
Mon Dec 11 21:20:06.503 2023 aos.info - AO loop closed
Mon Dec 11 21:20:06.504 2023 aos.Resume{FLAO}.complete - Resume{FLAO}[863]
Mon Dec 11 21:20:06.981 2023 aos.info - TTF offload: previous 1 requests ignored
Mon Dec 11 21:20:06.993 2023 aos.info - TTF Offload request (FLAO) Z: -0.158508 0.104963 0.000529329
Mon Dec 11 21:20:09.617 2023 aos.info - TTF offload command end
Mon Dec 11 21:20:09.978 2023 aos.info - TTF offload: previous 1 requests ignored
Mon Dec 11 21:20:09.993 2023 aos.info - TTF Offload request (FLAO) Z: 0.117211 -0.0393342 -0.000117344
Mon Dec 11 21:20:13.650 2023 aos.info - TTF offload command end
Mon Dec 11 21:20:13.985 2023 aos.info - TTF offload: previous 3 requests ignored

stopao

change to bin2

Error in bcu47

Arbitrator_71018|INF| 1284|2023-12-11 21:21:10.716155| MAIN > moveXYZ(): Focus correction (absolute): 0.000 mm
WfsArbitrator_71018|DEB| 1285|2023-12-11 21:21:10.718207| MAIN > doPresetAO(): moving FW2 to position 1.000000
WfsArbitrator_71018|INF| 1286|2023-12-11 21:21:10.752102| MAIN > Turning on PROG_BCU_47
WfsArbitrator_71018|INF| 1287|2023-12-11 21:21:10.752336| MAIN > Turning off RESET_BCU_47
WfsArbitrator_71018|ERR| 1288|2023-12-11 21:21:40.753632| MAIN > Cannot turn off RESET47-Active Low. Reason: Timeout waiting for powerboard.R.RESET_BCU_47.CUR - TIMEOUT_ERROR (-1000) GE

bcu47 reset was off.

another preset.

Mon Dec 11 21:30:17.953 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[895] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:12.7,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Dec 11 21:30:17.968 2023 aos.info - WFS source set to: FLAOWFS
Mon Dec 11 21:30:17.997 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1200.00_sd3892.fits

optimize

0.47,0.45,0.45

TN+luci+ncpa._214154,_214352,_

1.92,0.45,0.45

TN:_215905,

+ncpa_220128,_

modalSR 82, good residuals.

bin2_cl_angle.png

regorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Dec 11 22:09:11.037 2023 aos.info - WFS source set to: FLAOWFS
Mon Dec 11 22:09:11.067 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq900.00_sd3892.fits

loop stable.

Mon Dec 11 22:14:55.012 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[912] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Dec 11 22:14:55.030 2023 aos.info - WFS source set to: FLAOWFS
Mon Dec 11 22:14:55.062 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq200.00_sd3892.fits

optmze: 5.08,1.87

bin3_cl_angle.png

221904,_222448

3:20

Stop

NOte: Loop stable all the bin1 to bin3, expected performances. Not oscillation of high order modes.

-- JuanCarlosGuerra - 11 Dec 2023
I Attachment Action Size Date Who Comment
Move_leverapprox2mm.pngpng Move_leverapprox2mm.png manage 196 K 11 Dec 2023 - 18:34 JuanCarlosGuerra  
SR_cl_angle.pngpng SR_cl_angle.png manage 62 K 11 Dec 2023 - 21:15 JuanCarlosGuerra  
TT_cl_angle.pngpng TT_cl_angle.png manage 79 K 11 Dec 2023 - 21:15 JuanCarlosGuerra  
bin2_cl_angle.pngpng bin2_cl_angle.png manage 140 K 11 Dec 2023 - 22:36 JuanCarlosGuerra  
bin3_cl_angle.pngpng bin3_cl_angle.png manage 120 K 11 Dec 2023 - 22:36 JuanCarlosGuerra  
first_attempt.pngpng first_attempt.png manage 158 K 11 Dec 2023 - 18:07 JuanCarlosGuerra  
modalplot_cl_ngle.pngpng modalplot_cl_ngle.png manage 130 K 11 Dec 2023 - 21:15 JuanCarlosGuerra  
rotation_pupils_boardsetup.pngpng rotation_pupils_boardsetup.png manage 115 K 11 Dec 2023 - 16:24 JuanCarlosGuerra  
Topic revision: r2 - 11 Dec 2023, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.