Details.

Loaded version: test.20231130.bad-frames-phase-1.5

Power on WFs.

Restart system bayside stage tmeout.

Chamber temperature: 2.5C

at Dec 2 18:11:03.692 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[273] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Sat Dec 2 18:11:03.706 2023 aos.info - WFS source set to: FLAOWFS
Sat Dec 2 18:11:04.277 2023 aos.info - FLAO: WFS: loading setup for LUCIFER

Error preet.

Sat Dec 2 18:11:31.635 2023 aos.info - FLAO: WFS: configuring CCDs
Sat Dec 2 18:12:54.490 2023 aos.PresetAO{FLAO}.failed - PresetAO{FLAO}[273] - [AOException] presetAO: FATAL - Timeout waiting for pinger.R.bcu2k (-5001) TIMEOUT_ERROR
  • OCAm not live.
  • Rebin OCAM and come back live
Repeated preset.

until close loop

StartAO/StopAO

Sat Dec 2 18:20:13.075 2023 aos.Stop{FLAO}.complete - Stop{FLAO}[277]
Sat Dec 2 18:24:31.952 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[278] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Sat Dec 2 18:24:31.972 2023 aos.info - WFS source set to: FLAOWFS
Sat Dec 2 18:24:32.002 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1700.00_sd3892.fits

TN:20231202-183214.

184506,

185436,_191501,_192318,_

12:27

StopAO

Not issues during the close loop

temperaure hamber 2.8

change version:test.20231130.bad-frames-phase-1

power cycle 24.Homing bayside stages

8 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[284] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Sat Dec 2 19:36:04.938 2023 aos.info - WFS source set to: FLAOWFS
Sat Dec 2 19:36:04.970 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1700.00_sd3892.fits


Sat Dec 2 19:37:40.238 2023 aos.PresetAO{FLAO}.failed - PresetAO{FLAO}[284] - [AOException] presetAO: FATAL - Timeout error on baysidex (-5001) TIMEOUT_ERROR

int baysideX,

the Z stage not moving.

19:46:18.325778| WFS > Command returns error : Timeout error on baysidez (-5001) TIMEOUT_ERROR

w_stop/start-all

the stage Z still not moving, it apply current but it is. ot moving. the homing remain until the timeout.

power cycle the 24v and hayside stage driver

not luck

-- JuanCarlosGuerra - 02 Dec 2023