Staff.

Lbto: David, Jenny, Jared, Juan Carlos

Observer: Shark-Nir telescope control room

Forecast.

Screen Shot 2023-10-29 at 2.08.34 PM.png

Screen Shot 2023-10-29 at 2.09.16 PM.png

Details.

xwunit@lbti-sxwfs source]$ use_soul
Usage: use_soul [version]
Currently running: test.20231013.npca (soul)
Available versions in /home/sxwunit/soul:
checkout

power on 5:30PM

ocam ok.

telescope open 05:44

05:44 test preset.

Mon Oct 30 00:45:43.907 2023 aos.Stop{FLAO}.started - Stop{FLAO}[79] (msg:Starting Preset)
Mon Oct 30 00:45:43.954 2023 aos.Stop{FLAO}.complete - Stop{FLAO}[79]
Mon Oct 30 00:45:48.033 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[80] (aomode:ACE-AO,focst:bentGregorianCenter,instr:SHARK,wfs:LBTIWFS,sox:0[0],soy:0,rox:-0.210454[-0.210454],roy:-1.21092e-08,mag:2.94,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Oct 30 00:45:48.063 2023 aos.info - WFS source set to: LBTIWFS

CENTER PUPIL FAILED FIRST try.
  • center the pupil by hand and center pupil again
  • ok
  • 00:48:41.582755| MAIN > Camera lens tracking: AdSec is skipping frames, camera lens not moving
  • 00:48:42.704813| MAIN > Camera lens tracking: AdSec is skipping frames, camera lens not moving
  • 00:48:37.483492| COMMANDHANDLER > Command TTOffload (code 2029) successfully completed
    adsecarb.L.202310300002.log:AdSecArbitrator_42580|WAR| 1438|2023-10-30 00:48:40.034502| MAIN > Skip frame detected! (93.47% of frames skipped.)
    adsecarb.L.202310300002.log:AdSecArbitrator_42580|WAR| 1439|2023-10-30 00:48:41.041659| MAIN > Skip frame detected! (110.88% of frames skipped.)
    adsecarb.L.202310300002.log:AdSecArbitrator_42580|WAR| 1440|2023-10-30 00:48:41.041852| MAIN > Maximum skip frames reached: 110.88% of frames skipped. Will alert ICE clients.
    adsecarb.L.202310300002.log:AdSecArbitrator_42580|WAR| 1441|2023-10-30 00:48:42.078270| MAIN > Skip frame detected! (108.18% of frames skipped.)
    adsecarb.L.202310300002.log:AdSecArbitrator_42580|WAR| 1442|2023-10-30 00:48:42.078383| MAIN > Maximum skip frames reached: 108.18% of frames skipped. Will alert ICE clients.
    adsecarb.L.202310300002.log:AdSecArbitrator_42580|INF| 1443|2023-10-30 00:48:42.498534| MAIN > Received cmd: StopAo(1)

20231030_005648,_005759,_010258,_010313

sloperms 1.34,ModalSR 83, ratio 0.2

shark-nir pupil aligmenmt using the bright object....
_011655,_011901

Mon Oct 30 01:19:39.340 2023 aos.Stop{FLAO}.started - Stop{FLAO}[84] (msg:Starting Preset)
Mon Oct 30 01:19:39.352 2023 aos.Stop{FLAO}.complete - Stop{FLAO}[84]
Mon Oct 30 01:19:43.697 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[85] (aomode:ACE-AO,focst:bentGregorianCenter,instr:SHARK,wfs:LBTIWFS,sox:0[0],soy:0,rox:-0.46716[-0.46716],roy:3.16762e-08,mag:12.37,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Oct 30 01:19:43.726 2023 aos.info - WFS source set to: LBTIWFS

stop. Wrong target not reacheable....

adsec went rest.

back to zenith and set the shells.

Mon Oct 30 01:24:51.831 2023 aos.Stop{FLAO}.complete - Stop{FLAO}[88]
Mon Oct 30 01:24:55.692 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[89] (aomode:ACE-AO,focst:bentGregorianCenter,instr:SHARK,wfs:LBTIWFS,sox:0[0],soy:0,rox:-0.109463[-0.109463],roy:-2.0096e-08,mag:12.8,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Oct 30 01:24:55.722 2023 aos.info - WFS source set to: LBTIWFS

20231030_013233,_

sloperms3.9 sr:60 variable...ratio0.1

too variable gopt ratio...

_013544,_013744

seeing 1.4 sloperms 3.7, ratio 0.11

_014022 sloperms3.6, 0.15

_014302, sloperms4.3 seeing. 1.4, ratio 0.1, SR ~40

improved signal 13.8 sloperms2.6 seeing 1 modalSR 60, 0.17

_014817,_014833

_015629

slope 2.5 SR 60,ratio0.22 2eeing 1.2, 13.8

seeing 1.47 sloperms 3.4 SR 40,ratio 0.14

Note:

  • pupil in Y requires to apply a shift. with a fluctuation of seeing goes to -100..
_021125 sloperms 5, seeing 1.12 , ratio 0.1

sloperms3.7 ratio 0.12 seeing 1.1 modalSR40

seeing 1.5 _022219 sloperms5.2, ratio 0.07

_023525,_023543

stable seeing modalSR 65, sloperms2.5 ratio0.18-0.22 stable.....

_031334

slope zero event.

03:26:28.001709| MAIN > insert into optloopdiag_L_SLOPERMS (date_t,time_t,optloopdiag_L_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),2.74865)
DBFiller_16923 |INF| 377649|2023-10-30 03:26:28.815226| MAIN > insert into optloopdiag_L_COUNTS (date_t,time_t,optloopdiag_L_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),2280)
DBFiller_16923 |INF| 377691|2023-10-30 03:26:30.001957| MAIN > insert into optloopdiag_L_SLOPERMS (date_t,time_t,optloopdiag_L_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),2.73739)
DBFiller_16923 |INF| 377711|2023-10-30 03:26:30.861070| MAIN > insert into optloopdiag_L_COUNTS (date_t,time_t,optloopdiag_L_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),2783)
DBFiller_16923 |INF| 377762|2023-10-30 03:26:32.001924| MAIN > insert into optloopdiag_L_SLOPERMS (date_t,time_t,optloopdiag_L_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),1.42783)
DBFiller_16923 |INF| 377774|2023-10-30 03:26:32.870520| MAIN > insert into optloopdiag_L_COUNTS (date_t,time_t,optloopdiag_L_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),2783)
DBFiller_16923 |INF| 377813|2023-10-30 03:26:34.002416| MAIN > insert into optloopdiag_L_SLOPERMS (date_t,time_t,optloopdiag_L_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),0.116224)
DBFiller_16923 |INF| 377829|2023-10-30 03:26:34.880554| MAIN > insert into optloopdiag_L_COUNTS (date_t,time_t,optloopdiag_L_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),2783)

seeing:1.2 _033230,sloperms 2.38, ratio 0.22

seeing 1.57

_033724

seeing 1.45-

slope zero coincide with a seeing up to 2"

DBFiller_16923 |INF| 425407|2023-10-30 03:49:06.547423| MAIN > insert into optloopdiag_L_COUNTS (date_t,time_t,optloopdiag_L_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),2017)
DBFiller_16923 |INF| 425419|2023-10-30 03:49:07.002442| MAIN > insert into optloopdiag_L_SLOPERMS (date_t,time_t,optloopdiag_L_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),2.95435)
DBFiller_16923 |INF| 425476|2023-10-30 03:49:08.565223| MAIN > insert into optloopdiag_L_COUNTS (date_t,time_t,optloopdiag_L_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),2922)
DBFiller_16923 |INF| 425488|2023-10-30 03:49:09.002142| MAIN > insert into optloopdiag_L_SLOPERMS (date_t,time_t,optloopdiag_L_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),1.36748)
DBFiller_16923 |INF| 425535|2023-10-30 03:49:10.586828| MAIN > insert into optloopdiag_L_COUNTS (date_t,time_t,optloopdiag_L_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),2922)
DBFiller_16923 |INF| 425547|2023-10-30 03:49:11.014041| MAIN > insert into optloopdiag_L_SLOPERMS (date_t,time_t,optloopdiag_L_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),0)
DBFiller_16923 |INF| 425586|2023-10-30 03:49:12.598154| MAIN > insert into optloopdiag_L_COUNTS (date_t,time_t,optloopdiag_L_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),2922)

3:56:38.865 2023 aos.Stop{FLAO}.started - Stop{FLAO}[103] (msg:Starting Preset)
Mon Oct 30 03:56:38.889 2023 aos.Stop{FLAO}.complete - Stop{FLAO}[103]
Mon Oct 30 03:56:43.362 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[104] (aomode:ACE-AO,focst:bentGregorianCenter,instr:SHARK,wfs:LBTIWFS,sox:0[0],soy:0,rox:-0.154181[-0.154181],roy:1.34503e-07,mag:12.37,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Oct 30 03:56:43.375 2023 aos.info - WFS source set to: LBTIWFS

preset cancel. DX not found the star.

3:44.174 2023 aos.Stop{FLAO}.complete - Stop{FLAO}[106]
Mon Oct 30 04:03:48.414 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[107] (aomode:ACE-AO,focst:bentGregorianCenter,instr:SHARK,wfs:LBTIWFS,sox:0[0],soy:0,rox:-0.138381[-0.138381],roy:-1.19239e-07,mag:4.44,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Oct 30 04:03:48.444 2023 aos.info - WFS source set to: LBTIWFS

bin3,977Hz

mag 14.7

seeing 1.22, sloperms 4.4, modalSR37,ratio 15

_041321,_041415

Note

  • camera lens at Y -100 diffY-0.25
3.4 seeing 1.37,ratio:21

seeing 1.33 sloperms 3.19, ratio:0.22,modalSR 48

sloperms3.9 seeign 1.36 ratio: 0.20,modalSR40 043612,

loop open 09:43

adsecarb.L.202310300002.log:AdSecArbitrator_42580|WAR| 1857|2023-10-30 04:42:27.183622| MAIN > Skip frame detected! (10.44% of frames skipped.)
adsecarb.L.202310300002.log:AdSecArbitrator_42580|WAR| 1858|2023-10-30 04:42:28.189724| MAIN > Skip frame detected! (108.50% of frames skipped.)
adsecarb.L.202310300002.log:AdSecArbitrator_42580|WAR| 1859|2023-10-30 04:42:28.189822| MAIN > Maximum skip frames reached: 108.50% of frames skipped. Will alert ICE clients.
adsecarb.L.202310300002.log:AdSecArbitrator_42580|WAR| 1860|2023-10-30 04:42:29.196391| MAIN > Skip frame detected! (110.03% of frames skipped.)
adsecarb.L.202310300002.log:AdSecArbitrator_42580|WAR| 1861|2023-10-30 04:42:29.196525| MAIN > Maximum skip frames reached: 110.03% of frames skipped. Will alert ICE clients.
adsecarb.L.202310300002.log:AdSecArbitrator_42580|INF| 1862|2023-10-30 04:42:29.201580| MAIN > Received cmd: StopAo(1)

04:42:29.547484| MAIN > Forces out of safe range ID: # 26 #111 #138 #139 #165 #166 #167

DBFiller_16923 |INF| 537871|2023-10-30 04:42:27.002399| MAIN > insert into optloopdiag_L_SLOPERMS (date_t,time_t,optloopdiag_L_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),5.1647)
DBFiller_16923 |INF| 537919|2023-10-30 04:42:28.294610| MAIN > insert into optloopdiag_L_COUNTS (date_t,time_t,optloopdiag_L_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),1430)
DBFiller_16923 |INF| 537937|2023-10-30 04:42:29.002759| MAIN > insert into optloopdiag_L_SLOPERMS (date_t,time_t,optloopdiag_L_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),6.31836)
DBFiller_16923 |INF| 538022|2023-10-30 04:42:30.315609| MAIN > insert into optloopdiag_L_COUNTS (date_t,time_t,optloopdiag_L_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),294)

seeing 1.4,sloperms4.9 _044605,ratio:0.15

1.52,sloperms3.7-3.8 ,ratio 0.14,sr 0.42

1.6,sloperms3.9 ,_045640,ratio 0.15

1.4 sloperms 5.3 _050434,ratio0.17

1.41, sloperms4.9

10:07 change improve the sloperms from 5 to 4.5....._050806

10:09 improve the performa ces sloperms drops to 4.1

optimize again slope rms keep up to 6....

052243,

slope zero duin ght e gopt apply process.

DBFiller_16923 |INF| 641422|2023-10-30 05:31:28.001509| MAIN > insert into optloopdiag_L_SLOPERMS (date_t,time_t,optloopdiag_L_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),0.0733632)
DBFiller_16923 |INF| 641472|2023-10-30 05:31:28.668585| MAIN > insert into optloopdiag_L_COUNTS (date_t,time_t,optloopdiag_L_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),1578)
DBFiller_16923 |INF| 641523|2023-10-30 05:31:30.677484| MAIN > insert into optloopdiag_L_COUNTS (date_t,time_t,optloopdiag_L_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),1578)
DBFiller_16923 |INF| 641526|2023-10-30 05:31:30.678202| MAIN > insert into optloopdiag_L_SLOPERMS (date_t,time_t,optloopdiag_L_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),0)

sloperms:6

drop to 4.1, ratio 0.14 053623,_053640,

_054613 stable gopt, sloperms4.2

10:48PM
  • issue with bcu47 on DX side, it not reacheable. jenny power off the cabinet...
  • troubleshooting
  • not resolved.
5.1 seeing 1.45 _055918,SR35,gopt 0.15

2.30 sloperms 5.3 going up to 6, gopt 0.04

1.81 sloperms 5.6 ratio 0.10

1.68 sloperms 6.7 ratio 0.09

seeing 2.2 sloperms 7.4 ,ratio 0.08

_061450 sloprms 4.5 seeing 1.55 ratio 0.13

_061733,sloperms4.4 ratio:0.10

seeing 1.65, sloperms5.4_062642,ratio:0.12,

seeing going up 2" and slope zero

DBFiller_16923 |INF| 765915|2023-10-30 06:30:36.002909| MAIN > insert into optloopdiag_L_SLOPERMS (date_t,time_t,optloopdiag_L_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),8.86573)
DBFiller_16923 |INF| 765990|2023-10-30 06:30:38.001671| MAIN > insert into optloopdiag_L_SLOPERMS (date_t,time_t,optloopdiag_L_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),6.14853)
DBFiller_16923 |INF| 766011|2023-10-30 06:30:38.660053| MAIN > insert into optloopdiag_L_COUNTS (date_t,time_t,optloopdiag_L_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),1787)
DBFiller_16923 |INF| 766047|2023-10-30 06:30:40.000922| MAIN > insert into optloopdiag_L_SLOPERMS (date_t,time_t,optloopdiag_L_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),1.06286)
DBFiller_16923 |INF| 766085|2023-10-30 06:30:40.687085| MAIN > insert into optloopdiag_L_COUNTS (date_t,time_t,optloopdiag_L_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),1787)
DBFiller_16923 |INF| 766136|2023-10-30 06:30:42.698434| MAIN > insert into optloopdiag_L_COUNTS (date_t,time_t,optloopdiag_L_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),1787)

:31:58.756 2023 aos.Stop{FLAO}.complete - Stop{FLAO}[114]
Mon Oct 30 06:32:03.042 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[115] (aomode:ACE-AO,focst:bentGregorianCenter,instr:SHARK,wfs:LBTIWFS,sox:0[0],soy:0,rox:-0.0415515[-0.0415515],roy:2.24096e-08,mag:7.49,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Oct 30 06:32:03.056 2023 aos.info - WFS source set to: LBTIWFS

_064123 sloperms1.83, ratio0.21,

2023-10-30 06:46:43.296875| -13006 - Illegal command for state ReadyForStartAO
2023-10-30 06:46:56.898588| -13006 - Illegal command for state ReadyForStartAO
2023-10-30 06:47:36.596094| -13006 - Illegal command for state ReadyForStartAO

negative intensities.

DBFiller_16923 |INF| 799460|2023-10-30 06:46:39.787907| MAIN > insert into optloopdiag_L_COUNTS (date_t,time_t,optloopdiag_L_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),47503)
DBFiller_16923 |INF| 799472|2023-10-30 06:46:40.002227| MAIN > insert into optloopdiag_L_SLOPERMS (date_t,time_t,optloopdiag_L_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),0.619662)
DBFiller_16923 |INF| 799496|2023-10-30 06:46:41.003087| MAIN > insert into optloopdiag_L_COUNTS (date_t,time_t,optloopdiag_L_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),-1.29424e+06)

sloperms 1.3 gopt 0.3 SR 77,_065943

_070222

sloperms1.76 modalSR 77 stable,gopt 0.22, seeig ?

slope zero.

TE(),CURRENT_TIME(),45604)
DBFiller_16923 |INF| 853741|2023-10-30 07:12:42.003337| MAIN > insert into optloopdiag_L_SLOPERMS (date_t,time_t,optloopdiag_L_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),2.04085)
DBFiller_16923 |INF| 853783|2023-10-30 07:12:43.738314| MAIN > insert into optloopdiag_L_COUNTS (date_t,time_t,optloopdiag_L_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),42641)
DBFiller_16923 |INF| 853792|2023-10-30 07:12:44.004327| MAIN > insert into optloopdiag_L_SLOPERMS (date_t,time_t,optloopdiag_L_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),2.08399)
DBFiller_16923 |INF| 853892|2023-10-30 07:12:45.760110| MAIN > insert into optloopdiag_L_COUNTS (date_t,time_t,optloopdiag_L_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),44868)
DBFiller_16923 |INF| 853930|2023-10-30 07:12:46.002757| MAIN > insert into optloopdiag_L_SLOPERMS (date_t,time_t,optloopdiag_L_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),1.03226)
DBFiller_16923 |INF| 853982|2023-10-30 07:12:47.774731| MAIN > insert into optloopdiag_L_COUNTS (date_t,time_t,optloopdiag_L_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),41363)
DBFiller_16923 |INF| 853991|2023-10-30 07:12:48.004183| MAIN > insert into optloopdiag_L_SLOPERMS (date_t,time_t,optloopdiag_L_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),0)

_071641, sloperms1.67 gopt,0.25,SR.76

sloperms 1.3

slope 1.27 , ratio.0.3,_074037,_

2.33 _074738,SR 70,gopt 0.2

loop open.

N > insert into optloopdiag_L_COUNTS (date_t,time_t,optloopdiag_L_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),36501)
DBFiller_16923 |INF| 953490|2023-10-30 08:00:36.003515| MAIN > insert into optloopdiag_L_SLOPERMS (date_t,time_t,optloopdiag_L_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),2.91737)
DBFiller_16923 |INF| 953556|2023-10-30 08:00:37.315516| MAIN > insert into optloopdiag_L_COUNTS (date_t,time_t,optloopdiag_L_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),35099)
DBFiller_16923 |INF| 953565|2023-10-30 08:00:38.022064| MAIN > insert into optloopdiag_L_SLOPERMS (date_t,time_t,optloopdiag_L_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),2.96541)
D
DBFiller_16923 |INF| 953646|2023-10-30 08:00:40.003838| MAIN > insert into optloopdiag_L_SLOPERMS (date_t,time_t,optloopdiag_L_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),4.15015)

DBFiller_16923 |INF| 953712|2023-10-30 08:00:42.002982| MAIN > insert into optloopdiag_L_SLOPERMS (date_t,time_t,optloopdiag_L_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),5.31319)

DBFiller_16923 |INF| 953793|2023-10-30 08:00:44.003341| MAIN > insert into optloopdiag_L_SLOPERMS (date_t,time_t,optloopdiag_L_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),4.24884)

DBFiller_16923 |INF| 953875|2023-10-30 08:00:46.004497| MAIN > insert into optloopdiag_L_SLOPERMS (date_t,time_t,optloopdiag_L_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),1.9751)

DBFiller_16923 |INF| 953932|2023-10-30 08:00:48.002438| MAIN > insert into optloopdiag_L_SLOPERMS (date_t,time_t,optloopdiag_L_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),0.663935)

_080621 sloperms`.66 seeing 1.44, gopt 0.27

_081106,sloperms2.3, seeing 1.8-1.6 gopt0.15

-081812 gopt0.14, seeing 2

_slopersm1.77 gopt 0.24, SR 80 seeing 1.7

Mon Oct 30 08:48:49.679 2023 aos.info - Updated variable AOARB.L.AO_READY: 0
Mon Oct 30 08:48:50.504 2023 aos.info - Updated variable AOARB.L.AO_READY: 1
Mon Oct 30 08:48:50.504 2023 aos.PresetAO{FLAO}.complete - PresetAO{FLAO}[128] - dx:nan dy:nan slNull: f1:1.0 f2:2.0 freq:1700 mag:0 nBins:1 nModes:500 r0:nan snMode:0 strehl:0 ttMod:0

_085851 seeing 1.3 sloperms 1.4 0.34

_085938,_gopt 0.32,slperms 1.3

090159,sloperms1.3 seieng 1.23

_091127,sloperms 1.2 seeing 1.1,gopt0.35

_091658,sloperms1.18 gopt 0.32 seeing 1.32

seing 1.04 sloperms 1.1 _092553,gopt 0.35

negative counts.

DBFiller_16923 |INF| 1140855|2023-10-30 09:29:16.004675| MAIN > insert into optloopdiag_L_SLOPERMS (date_t,time_t,optloopdiag_L_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),1.19795)
DBFiller_16923 |INF| 1140939|2023-10-30 09:29:18.002981| MAIN > insert into optloopdiag_L_COUNTS (date_t,time_t,optloopdiag_L_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),-1.23669e+06)

note:

  • camera lens negative X-100
  • correct one pixel in X
  • pupil error diffx =0.07
_094518 seeing 1.67 sloperms 1.7 gopt

_095904, seeing 1.4 sloperms 1.57, gopt 0.23

on Oct 30 10:08:04.601 2023 aos.Stop{FLAO}.complete - Stop{FLAO}[133]
Mon Oct 30 10:08:08.287 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[134] (aomode:ACE-AO,focst:bentGregorianCenter,instr:SHARK,wfs:LBTIWFS,sox:0[0],soy:0,rox:-0.0319117[-0.0319117],roy:1.11256e-07,mag:6.95,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Oct 30 10:08:08.299 2023 aos.info - WFS source set to: LBTIWFS

seeing 1.4" sloperms 2. _101749,gopt

seeing 2.2

sloperms 2.4 gopt _0.14 _103355,

sloperms 1 seeing 1.47 gopt 0.22,_

sloperms 1.3 seeing 1.46 gopt0.2, _104056

loop open bad seeing. ~2.4

_105508, seeing 1.61 sloperms1.9 gopt0.19

04:00 seeing up to 2.55

optimize.

_111503 seeing 1.39 sloperms 1.47 gopt 0.24

04:22 seign up to 2.4 low hpo1 and 2 one click stopped the skp frames.

_112326,seeing 2.33,sloperms 3.5 gopt0.07

04:30 seeing up to 5, loop open

04:36 seeing 1.7 optimize

seeing 2.2 gopt.

4:44

seeing 3 open loop

seeing 1.7 reclosed.

30 11:47:40.853 2023 aos.info - HO offload command end
Mon Oct 30 11:47:41.294 2023 aos.info - HO offload: previous 5 requests ignored
Mon Oct 30 11:47:41.311 2023 aos.info - HO Offload request (FLAO). Z: 0 0 0 0 15.2201 -20.0159 -16.6235 15.5378 14.8369 11.7015 4.89055 -0 0 -0 -0 -0 0 0 0 -0 -0 -0
Mon Oct 30 11:47:43.353 2023 aos.info - TTF offload command end
Mon Oct 30 11:47:44.294 2023 aos.info - TTF offload: previous 4 requests ignored
Mon Oct 30 11:47:44.309 2023 aos.info - TTF Offload request (FLAO) Z: -1.07736 1.01755 0.000600634
Mon Oct 30 11:47:46.867 2023 aos.info - HO offload command end
Mon Oct 30 11:47:47.297 2023 aos.info - HO offload: previous 5 requests ignored
Mon Oct 30 11:47:47.311 2023 aos.info - HO Offload request (FLAO). Z: 0 0 0 0 -4.09157 -19.9445 -13.6372 6.31816 -2.59073 16.3109 -4.16263 -0 -0 -0 0 -0 0 0 -0 -0 -0 -0
Mon Oct 30 11:47:48.354 2023 aos.info - TTF offload command end
Mon Oct 30 11:47:49.298 2023 aos.info - TTF offload: previous 4 requests ignored
Mon Oct 30 11:47:49.313 2023 aos.info - TTF Offload request (FLAO) Z:

seeing 1.7

before the gopt applied and during_115414

seeing 2, sloperms1.75 gopt13, _115002

seeing 2, sloperms 2.2 gopt,0.15, _120016

seeing 2.0

skip frames reduce one click ho2

5:11

some stable until skip frames and loop forced to open.

seeing 2.2 close with LNgain

optimize 1.51

5:13

loop open.

optimize not gopt

sloperms2.27 seeing 1.57 gopt 0.14, _122449

sloperms 2.5 seeing 1.76 gopt 0.12 _122858

sloperms 1.9 seeing1.2 gopt0.18 _123234

sloperm 1.6 seeing 1.2 gopt0.22 -123409

sloperms1.3, seeing 1.1 gopt 0.26, modalSR80

sloperms1.68 seeing 1.04,gopt 0.21,-125453,SR~80

6:10 stopAO

close

DONE FOR TODAY... wink

-- JuanCarlosGuerra - 29 Oct 2023
Topic revision: r2 - 30 Oct 2023, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback