Staff:

LBTO: Alex, Steve, Juan Carlos

Observer: Shark-vs team (on site)

Summary.

Forecast.

Details.

Start up 3:30PM

Ocam OK

12:06am

reconfigure for shark-vis.

Fri Oct 20 07:23:19.046 2023 aos.Stop{FLAO}.complete - Stop{FLAO}[1196]
Fri Oct 20 07:23:22.801 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[1197] (aomode:ACE-AO,focst:bentGregorianCenter,instr:LBTI,wfs:LBTIWFS,sox:0[0],soy:0,rox:-0.0394902[-0.0394902],roy:2.91292e-07,mag:999,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Oct 20 07:23:22.814 2023 aos.info - WFS source set to: LBTIWFS
Fri Oct 20 07:23:22.841 2023 aos.PresetAO{FLAO}.failed - PresetAO{FLAO}[1197] - [AOException] presetAO: WARNING - RETRY: Star too faint for mode ACE-AO. Maximum magnitude is 20.5 (-5002) VALUE_OUT_OF_RANGE_ERROR

not star found in the CCD47 after spiral using the paddle.

recenter star

pointing OK

shark_lmircam_lp for fov. using the option

12: sharkvislmirhalpha (*) -42.790 -35.600

focus -22.5

for the ncpa using shark_lmircam_lp

02:00am

seeing getting worst.

event of negative counts.

loop in pause and event happens in that time the resume failed and it was necessary to cancel preset.

3:00

negative counts and loop pause, the loop was stopAO and it could be done a change of bin and restore the operations , recenter star, optimize and gopt

10:15 (4:14)

loop open executed an stopAO ? to be investigated.

Adsec reported command #145 out of range, suspicious that it had a jump, the PSF in the pyramid were all to only one top right

seeing impresive stable 0.7-0.5"

04:55

negative counts.

loop open.

chage bin -> OK

re-closed

gopt not tracking. three try not luck

repeat optimize gain.

gopt not tracking.. time out error

no working.

restart process and it not working.

WfsArbitrator_4566 |WAR| 2759|2023-10-20 11:58:25.792057| WFS > Command returns retryable error : RETRY: Cannot read current optical gain value (-5001) TIMEOUT_ERROR
WfsArbitrator_4566 |WAR| 2767|2023-10-20 11:59:35.246243| WFS > Command returns retryable error : RETRY: Cannot read current optical gain value (-5001) TIMEOUT_ERROR
WfsArbitrator_4566 |WAR| 2779|2023-10-20 12:01:10.829592| WFS > Command returns retryable error : RETRY: Cannot read current optical gain value (-5001) TIMEOUT_ERROR
WfsArbitrator_4566 |WAR| 2788|2023-10-20 12:02:19.978647| WFS > Command returns retryable error : RETRY: Cannot read current optical gain value (-5001) TIMEOUT_ERROR
WfsArbitrator_4566 |WAR| 2797|2023-10-20 12:03:43.009289| WFS > Command returns retryable error : RETRY: Cannot read current optical gain value (-5001) TIMEOUT_ERROR
WfsArbitrator_4566 |WAR| 2802|2023-10-20 12:04:13.011285| WFS > Command returns retryable error : RETRY: Cannot read current optical gain value (-5001) TIMEOUT_ERROR

Change target because it was only a few minutes left.

Gopt OK.

( to check why the gopt was not running..)

05:50 nudge.

The pause came too late. The GUI was frozen.

6:00

stop

cpontinuing with daytime..

mni ocam not live.. catched with the ocamview_log.

rewrite gopt ON

connected Soul-left

Done 9am.

-- JuanCarlosGuerra - 19 Oct 2023