summary

Close loop DX and SX to catch any slope zero events.

Details.

Dump good for SX

-rw-rw-r--. 1 sxwunit sxwunit 0 Oct 12 18:00 BCUread_32407.202310120000.log
-rw-rw-r--. 1 sxwunit sxwunit 4091 Oct 12 18:00 dumpBCU2KDSP_20231012_180003.txt
-rw-rw-r--. 1 sxwunit sxwunit 0 Oct 12 18:00 BCUread_32418.202310120000.log
-rw-rw-r--. 1 sxwunit sxwunit 364873 Oct 12 18:00 dumpBCU2KDSPext1_20231012_180003.txt
-rw-rw-r--. 1 sxwunit sxwunit 0 Oct 12 18:00 BCUread_32430.202310120000.log
-rw-rw-r--. 1 sxwunit sxwunit 364628 Oct 12 18:00 dumpBCU2KDSPext2_20231012_180003.txt
-rw-rw-r--. 1 sxwunit sxwunit 0 Oct 12 18:00 BCUread_32438.202310120000.log
-rw-rw-r--. 1 sxwunit sxwunit 986235 Oct 12 18:00 dumpBCU2KDSPext3_20231012_180003.txt
-rw-rw-r--. 1 sxwunit sxwunit 0 Oct 12 18:00 BCUread_32443.202310120000.log
-rw-rw-r--. 1 sxwunit sxwunit 11962 Oct 12 18:00 dumpBCU2KSRAM_20231012_180003.txt
-rw-rw-r--. 1 sxwunit sxwunit 0 Oct 12 18:00 BCUread_32447.202310120000.log
-rw-rw-r--. 1 sxwunit sxwunit 10738 Oct 12 18:00 dumpBCU2KSDRAM_20231012_180003.txt

Thu Oct 12 18:04:02.068 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[340] (aomode:ACE-AO,focst:bentGregorianCenter,instr:LBTI,wfs:LBTIWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Oct 12 18:04:02.084 2023 aos.info - WFS source set to: LBTIWFS
Thu Oct 12 18:04:02.131 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1700.00_sd3892.fits
Thu Oct 12 18:04:02.740 2023 aos.info - FLAO: WFS: loading setup for LBTI

dump good for DX.

-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 18:11 BCUread_28067.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 4151 Oct 12 18:11 dumpBCU2KDSP_20231012_181138.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 18:11 BCUread_28075.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 364716 Oct 12 18:11 dumpBCU2KDSPext1_20231012_181138.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 18:11 BCUread_28079.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 364663 Oct 12 18:11 dumpBCU2KDSPext2_20231012_181138.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 18:11 BCUread_28083.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 986509 Oct 12 18:11 dumpBCU2KDSPext3_20231012_181138.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 18:11 BCUread_28091.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 11962 Oct 12 18:11 dumpBCU2KSRAM_20231012_181138.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 18:11 BCUread_28095.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 10738 Oct 12 18:11 dumpBCU2KSDRAM_20231012_181138.txt

save DX:20231012_181616

saveSX:_181824,_183204

saveDX:_

11:35

dump SX and DX good.

11:57

dumpgood SX/DX

saveSX:_185736

saceDX:_185841

12:50

EVENT DX

saved dump.

-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 19:48 BCUread_5630.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 4167 Oct 12 19:48 dumpBCU2KDSP_20231012_194841.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 19:48 BCUread_5634.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 358439 Oct 12 19:48 dumpBCU2KDSPext1_20231012_194841.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 19:48 BCUread_5638.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 358443 Oct 12 19:48 dumpBCU2KDSPext2_20231012_194841.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 19:48 BCUread_5647.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 986507 Oct 12 19:48 dumpBCU2KDSPext3_20231012_194841.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 19:48 BCUread_5652.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 11962 Oct 12 19:48 dumpBCU2KSRAM_20231012_194841.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 19:48 BCUread_5656.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 10738 Oct 12 19:48 dumpBCU2KSDRAM_20231012_194841.txt
-rw-rw-rw-. 1 dxwunit dxwunit 230234 Oct 12 19:49 cameralensctrl.R.202310120000.log
-rw-r--r--. 1 dxwunit dxwunit 2834833 Oct 12 19:49 keep_up.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 19:49 BCUread_11194.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 4167 Oct 12 19:49 dumpBCU2KDSP_20231012_194927.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 19:49 BCUread_11198.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 358439 Oct 12 19:49 dumpBCU2KDSPext1_20231012_194927.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 19:49 BCUread_11202.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 358443 Oct 12 19:49 dumpBCU2KDSPext2_20231012_194927.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 19:49 BCUread_11210.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 986507 Oct 12 19:49 dumpBCU2KDSPext3_20231012_194927.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 19:49 BCUread_11214.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 11962 Oct 12 19:49 dumpBCU2KSRAM_20231012_194927.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 19:49 BCUread_11218.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 10738 Oct 12 19:49 dumpBCU2KSDRAM_20231012_194927.txt

stopAO

preset 12.7

cancel.

preset 10

stopSX

preset12.7

checkflux

close

dx dump good.

-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 19:59 BCUread_9120.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 4171 Oct 12 19:59 dumpBCU2KDSP_20231012_195923.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 19:59 BCUread_9125.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 364671 Oct 12 19:59 dumpBCU2KDSPext1_20231012_195923.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 19:59 BCUread_9134.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 364715 Oct 12 19:59 dumpBCU2KDSPext2_20231012_195923.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 19:59 BCUread_9139.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 986509 Oct 12 19:59 dumpBCU2KDSPext3_20231012_195923.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 19:59 BCUread_9147.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 11962 Oct 12 19:59 dumpBCU2KSRAM_20231012_195923.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 19:59 BCUread_9151.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 10738 Oct 12 19:59 dumpBCU2KSDRAM_20231012_195923.txt

DX ncap on/off

saveTN:_200031

Preset SX.

saved TN during NCPA on/off _200649

01:09PM

dump good.

-rw-rw-r-- 1 sxwunit sxwunit 0 Oct 12 20:09 BCUread_12270.202310120000.log
-rw-rw-r-- 1 sxwunit sxwunit 11962 Oct 12 20:09 dumpBCU2KSRAM_20231012_200905.txt
-rw-rw-r-- 1 sxwunit sxwunit 364635 Oct 12 20:09 dumpBCU2KDSPext2_20231012_200905.txt
-rw-rw-r-- 1 sxwunit sxwunit 0 Oct 12 20:09 BCUread_12278.202310120000.log
-rw-rw-r-- 1 sxwunit sxwunit 0 Oct 12 20:09 BCUread_12291.202310120000.log
-rw-rw-r-- 1 sxwunit sxwunit 0 Oct 12 20:09 BCUread_12283.202310120000.log
-rw-rw-r-- 1 sxwunit sxwunit 10738 Oct 12 20:09 dumpBCU2KSDRAM_20231012_200905.txt
-rw-rw-r-- 1 sxwunit sxwunit 0 Oct 12 20:09 BCUread_12274.202310120000.log
-rw-rw-r-- 1 sxwunit sxwunit 0 Oct 12 20:09 BCUread_12295.202310120000.log
-rw-rw-r-- 1 sxwunit sxwunit 364606 Oct 12 20:09 dumpBCU2KDSPext1_20231012_200905.txt
-rw-rw-r-- 1 sxwunit sxwunit 4094 Oct 12 20:09 dumpBCU2KDSP_20231012_200905.txt
-rw-rw-r-- 1 sxwunit sxwunit 986235 Oct 12 20:09 dumpBCU2KDSPext3_20231012_200905.txt

saved TN:
  • SX:_202439
  • DX:_202443
stopAO

SX and DX.

SX.

Oct 12 20:38 BCUread_13198.202310120000.log
-rw-rw-r-- 1 sxwunit sxwunit 4094 Oct 12 20:38 dumpBCU2KDSP_20231012_203831.txt
-rw-rw-r-- 1 sxwunit sxwunit 0 Oct 12 20:38 BCUread_13212.202310120000.log
-rw-rw-r-- 1 sxwunit sxwunit 364679 Oct 12 20:38 dumpBCU2KDSPext2_20231012_203831.txt
-rw-rw-r-- 1 sxwunit sxwunit 0 Oct 12 20:38 BCUread_13189.202310120000.log
-rw-rw-r-- 1 sxwunit sxwunit 10738 Oct 12 20:38 dumpBCU2KSDRAM_20231012_203831.txt
-rw-rw-r-- 1 sxwunit sxwunit 0 Oct 12 20:38 BCUread_13208.202310120000.log
-rw-rw-r-- 1 sxwunit sxwunit 0 Oct 12 20:38 BCUread_13184.202310120000.log
-rw-rw-r-- 1 sxwunit sxwunit 986237 Oct 12 20:38 dumpBCU2KDSPext3_20231012_203831.txt
-rw-rw-r-- 1 sxwunit sxwunit 0 Oct 12 20:38 BCUread_13194.202310120000.log
-rw-rw-r-- 1 sxwunit sxwunit 11962 Oct 12 20:38 dumpBCU2KSRAM_20231012_203831.txt
-rw-rw-r-- 1 sxwunit sxwunit 364552 Oct 12 20:38 dumpBCU2KDSPext1_20231012_203831.txt

Dx.

-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 20:38 BCUread_9329.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 4153 Oct 12 20:38 dumpBCU2KDSP_20231012_203836.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 20:38 BCUread_9333.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 364732 Oct 12 20:38 dumpBCU2KDSPext1_20231012_203836.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 20:38 BCUread_9338.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 364694 Oct 12 20:38 dumpBCU2KDSPext2_20231012_203836.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 20:38 BCUread_9342.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 986511 Oct 12 20:38 dumpBCU2KDSPext3_20231012_203836.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 20:38 BCUread_9350.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 11962 Oct 12 20:38 dumpBCU2KSRAM_20231012_203836.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 20:38 BCUread_9355.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 10738 Oct 12 20:38 dumpBCU2KSDRAM_20231012_203836.txt
-rw-rw-rw-. 1 dxwunit dxwunit 477120 Oct 12 20:39 slopecompctrl.R.202310120000.log

DX slope zero?

IT SEEMS ANOTHER ISSUE RELATED , THERE IS FOLLOW OF THE CAMERa lens and it seems a large applied TTF.


20:39:49.522601| MAIN > Camera lens tracking: moving by x= -0.7 y= 1.0 (um)
20:40:08.103267| MAIN > Camera lens tracking: moving by x= 4.4 y= 34.0 (um)
20:41:07.834262| WFS > Executing stopLoop...
------------

20:39:05.000014| MAIN > insert into optloopdiag_R_COUNTS (date_t,time_t,optloopdiag_R_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),14474)
DBFiller_651 |INF| 413581|2023-10-12 20:39:06.019747| MAIN > insert into optloopdiag_R_COUNTS (date_t,time_t,optloopdiag_R_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),14610)
DBFiller_651 |INF| 413657|2023-10-12 20:39:08.051019| MAIN > insert into optloopdiag_R_COUNTS (date_t,time_t,optloopdiag_R_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),14610)
DBFiller_651 |INF| 413723|2023-10-12 20:39:10.064507| MAIN > insert into optloopdiag_R_COUNTS (date_t,time_t,optloopdiag_R_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),14610)
DBFiller_651 |INF| 413771|2023-10-12 20:39:12.075034| MAIN > insert into optloopdiag_R_COUNTS (date_t,time_t,optloopdiag_R_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),14610)
DBFiller_651 |INF| 413872|2023-10-12 20:39:14.096367| MAIN > insert into optloopdiag_R_COUNTS (date_t,time_t,optloopdiag_R_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),14610)
DBFiller_651 |INF| 413956|2023-10-12 20:39:16.115546| MAIN > insert into optloopdiag_R_COUNTS (date_t,time_t,optloopdiag_R_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),14610)
DBFiller_651 |INF| 414004|2023-10-12 20:39:18.126739| MAIN > insert into optloopdiag_R_COUNTS (date_t,time_t,optloopdiag_R_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),14610)
DBFiller_651 |INF| 414033|2023-10-12 20:39:20.003574| MAIN > insert into optloopdiag_R_COUNTS (date_t,time_t,optloopdiag_R_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),15408)
DBFiller_651 |INF| 414087|2023-10-12 20:39:22.003184| MAIN > insert into optloopdiag_R_COUNTS (date_t,time_t,optloopdiag_R_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),13906)
DBFiller_651 |INF| 414147|2023-10-12 20:39:24.024266| MAIN > insert into optloopdiag_R_COUNTS (date_t,time_t,optloopdiag_R_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),15055)
DBFiller_651 |INF| 414262|2023-10-12 20:39:26.214416| MAIN > insert into optloopdiag_R_COUNTS (date_t,time_t,optloopdiag_R_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),15055)
DBFiller_651 |INF| 414279|2023-10-12 20:39:28.003355| MAIN > insert into optloopdiag_R_COUNTS (date_t,time_t,optloopdiag_R_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),14193)
DBFiller_651 |INF| 414327|2023-10-12 20:39:30.003783| MAIN > insert into optloopdiag_R_COUNTS (date_t,time_t,optloopdiag_R_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),13313)
DBFiller_651 |INF| 414402|2023-10-12 20:39:32.004094| MAIN > insert into optloopdiag_R_COUNTS (date_t,time_t,optloopdiag_R_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),14341)
DBFiller_651 |INF| 414455|2023-10-12 20:39:34.004592| MAIN > insert into optloopdiag_R_COUNTS (date_t,time_t,optloopdiag_R_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),11995)
DBFiller_651 |INF| 414553|2023-10-12 20:39:36.279062| MAIN > insert into optloopdiag_R_COUNTS (date_t,time_t,optloopdiag_R_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),11995)
DBFiller_651 |INF| 414585|2023-10-12 20:39:38.004302| MAIN > insert into optloopdiag_R_COUNTS (date_t,time_t,optloopdiag_R_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),9992)
DBFiller_651 |INF| 414717|2023-10-12 20:39:40.367481| MAIN > insert into optloopdiag_R_COUNTS (date_t,time_t,optloopdiag_R_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),9992)
DBFiller_651 |INF| 414808|2023-10-12 20:39:42.395024| MAIN > insert into optloopdiag_R_COUNTS (date_t,time_t,optloopdiag_R_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),9992)
DBFiller_651 |INF| 414890|2023-10-12 20:39:44.411515| MAIN > insert into optloopdiag_R_COUNTS (date_t,time_t,optloopdiag_R_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),9992)
DBFiller_651 |INF| 414976|2023-10-12 20:39:46.432737| MAIN > insert into optloopdiag_R_COUNTS (date_t,time_t,optloopdiag_R_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),9992)
DBFiller_651 |INF| 415027|2023-10-12 20:39:48.443525| MAIN > insert into optloopdiag_R_COUNTS (date_t,time_t,optloopdiag_R_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),9992)
DBFiller_651 |INF| 415096|2023-10-12 20:39:50.457726| MAIN > insert into optloopdiag_R_COUNTS (date_t,time_t,optloopdiag_R_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),9992)
DBFiller_651 |INF| 415165|2023-10-12 20:39:52.482934| MAIN > insert into optloopdiag_R_COUNTS (date_t,time_t,optloopdiag_R_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),9992)

20:39:12.002641| MAIN > insert into optloopdiag_R_SLOPERMS (date_t,time_t,optloopdiag_R_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),1.47184)
DBFiller_651 |INF| 413815|2023-10-12 20:39:14.002470| MAIN > insert into optloopdiag_R_SLOPERMS (date_t,time_t,optloopdiag_R_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),0.757197)
DBFiller_651 |INF| 413906|2023-10-12 20:39:16.003045| MAIN > insert into optloopdiag_R_SLOPERMS (date_t,time_t,optloopdiag_R_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),0.0294559)
DBFiller_651 |INF| 414007|2023-10-12 20:39:18.127311| MAIN > insert into optloopdiag_R_SLOPERMS (date_t,time_t,optloopdiag_R_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),0)
DBFiller_651 |INF| 414073|2023-10-12 20:39:20.167470| MAIN > insert into optloopdiag_R_SLOPERMS (date_t,time_t,optloopdiag_R_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),0)
DBFiller_651 |INF| 414130|2023-10-12 20:39:22.181689| MAIN > insert into optloopdiag_R_SLOPERMS (date_t,time_t,optloopdiag_R_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),0)
DBFiller_651 |INF| 414186|2023-10-12 20:39:24.196857| MAIN > insert into optloopdiag_R_SLOPERMS (date_t,time_t,optloopdiag_R_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),0)
DBFiller_651 |INF| 414265|2023-10-12 20:39:26.215105| MAIN > insert into optloopdiag_R_SLOPERMS (date_t,time_t,optloopdiag_R_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),0)
DBFiller_651 |INF| 414313|2023-10-12 20:39:28.222850| MAIN > insert into optloopdiag_R_SLOPERMS (date_t,time_t,optloopdiag_R_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),0)
DBFiller_651 |INF| 414361|2023-10-12 20:39:30.234327| MAIN > insert into optloopdiag_R_SLOPERMS (date_t,time_t,optloopdiag_R_SLOPERMS1) values (CURRENT_DATE(),CURRENT_TIME(),0)
DBFiller_651 |INF| 414436|2023-10-12 20:39:32.247785| MAIN > inse

saved dump

-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 20:40 BCUread_24524.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 4153 Oct 12 20:40 dumpBCU2KDSP_20231012_204057.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 20:40 BCUread_24528.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 358441 Oct 12 20:40 dumpBCU2KDSPext1_20231012_204057.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 20:40 BCUread_24536.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 358447 Oct 12 20:40 dumpBCU2KDSPext2_20231012_204057.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 20:40 BCUread_24540.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 986509 Oct 12 20:40 dumpBCU2KDSPext3_20231012_204057.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 20:40 BCUread_24550.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 11962 Oct 12 20:40 dumpBCU2KSRAM_20231012_204057.txt
-rw-rw-r--. 1 dxwunit dxwunit 0 Oct 12 20:40 BCUread_24554.202310120000.log
-rw-rw-r--. 1 dxwunit dxwunit 10738 Oct 12 20:40 dumpBCU2KSDRAM_20231012_204057.txt

savedTN:

SX:_205055

DX:_20055

01:55PM

saved good dump

Oct 12 20:54 dumpBCU2KSDRAM_20231012_205443.txt
-rw-rw-r-- 1 dxwunit dxwunit 0 Oct 12 20:54 BCUread_13710.202310120000.log
-rw-rw-r-- 1 dxwunit dxwunit 0 Oct 12 20:54 BCUread_13724.202310120000.log
-rw-rw-r-- 1 dxwunit dxwunit 986511 Oct 12 20:54 dumpBCU2KDSPext3_20231012_205443.txt
-rw-rw-r-- 1 dxwunit dxwunit 0 Oct 12 20:54 BCUread_13715.202310120000.log
-rw-rw-r-- 1 dxwunit dxwunit 0 Oct 12 20:54 BCUread_13696.202310120000.log
-rw-rw-r-- 1 dxwunit dxwunit 4153 Oct 12 20:54 dumpBCU2KDSP_20231012_205443.txt
-rw-rw-r-- 1 dxwunit dxwunit 0 Oct 12 20:54 BCUread_13692.202310120000.log
-rw-rw-r-- 1 dxwunit dxwunit 11962 Oct 12 20:54 dumpBCU2KSRAM_20231012_205443.txt
-rw-rw-r-- 1 dxwunit dxwunit 364658 Oct 12 20:54 dumpBCU2KDSPext1_20231012_205443.txt
-rw-rw-r-- 1 dxwunit dxwunit 0 Oct 12 20:54 BCUread_13704.202310120000.log
-rw-rw-r-- 1 dxwunit dxwunit 364629 Oct 12 20:54 dumpBCU2KDSPext2_20231012_205443.txt

2:14PM

SX:stopAO

SX preset 12.7

change bin2

ocam not live.

reset BCU through the..Bin1

OK

PresetAO

check flux.

OK.

2:21

StopDX

DXPreset mag10

2:22 saved dump bcu AOprepare.

saved a dump and the OAm got stuck. loop still closed.

\cgeck the ocam viewer log.

Open loop ocam live.

presetaAO

still shoing the ocam not live masterdiagnotic buffer.

change bin from wfscontrolgui.

masterdiagnotic process was down

restart process and preset

continous reset of the masterdiagnotic

frame sizes, etc.. not right.

only solution power cycle the BCU2K (#16) rebin 1x1 cropped.

ocam live.

ok

preset.

2:40 DX dumpdsp good..

2:55 stopAO both

preset 12.7

check flux.

2:59PM

good dump

03:10PM

StopAO

-- JuanCarlosGuerra - 12 Oct 2023
Topic revision: r2 - 13 Oct 2023, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback