10:30am

Power on

There is a tour, requested to have 30m lights on.

OCAm ok

Tue Oct 10 19:06:24.478 2023 aos.info - Doing PresetFlat(LUCIFER)
Tue Oct 10 19:06:49.354 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[369] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Oct 10 19:06:49.372 2023 aos.info - WFS source set to: FLAOWFS
Tue Oct 10 19:06:49.491 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.6_L040.0_v15.0_ovfreq1700.00_sd3892.fits

Tue Oct 10 20:26:26.703 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[373] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Oct 10 20:26:26.720 2023 aos.info - WFS source set to: FLAOWFS
Tue Oct 10 20:26:26.770 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.6_L040.0_v15.0_ovfreq1700.00_sd3892.fits

remove the daytime in: /home/AOeng/live/aoroot/conf/wfs/current/processConf

lfbg to 360 degrees.

skip frames, the camera lens moves.

the loop continues to open when it reaches 300 degrees.

the pupils starts to get off., the camera lens tracking is active.

restart the wfsarb.

Could be an issue with the re-rotator?

presetAO

camera lens positons is zero

error of share masterdiagnotc buffer.

0 20:58:31.089389| MAIN > ccd.equalize_quadrants(): nothing to do for ocam2
WfsArbitrator_56015|ERR| 138|2023-10-10 20:58:35.223311| MAIN > Reading shared buffer masterdiagnostic.L:OPTLOOPBUF (-5001) TIMEOUT_ERROR


MasterDiagnostic_34788|WAR| 29270|2023-10-10 20:55:43.311662| BCU39 > FramesDownloader BCU39: [InvalidDiagnosticPacketException] Unexpected packetId 1 for frameId 500 (instead of packetId 0 for frameId 500)
MasterDiagnostic_34788|WAR| 29271|2023-10-10 20:55:43.311680| BCU39 > FramesDownloader BCU39: packet successfully ignored !
MasterDiagnostic_34788|WAR| 29272|2023-10-10 20:55:43.311726| BCU39 > FramesDownloader BCU39: [InvalidDiagnosticPacketException] Unexpected packetId 2 for frameId 500 (instead of packetId 0 for frameId 500)
MasterDiagnostic_34788|WAR| 29273|2023-10-10 20:55:43.311742| BCU39 > FramesDownloader BCU39: packet successfully ignored !
MasterDiagnostic_34788|INF| 29274|2023-10-10 20:56:00.053885| MAIN > Setting optical loop CLOSED
MasterDiagnostic_34788|INF| 29275|2023-10-10 20:56:00.054004| MAIN > Optical loop set to 1 ...
MasterDiagnostic_34788|INF| 29276|2023-10-10 20:56:38.677457| MAIN > Setting optical loop OPEN
MasterDiagnostic_34788|INF| 29277|2023-10-10 20:56:38.677605| MAIN > Optical loop set to 0 ...
MasterDiagnostic_34788|INF| 29278|2023-10-10 20:57:46.338232| MAIN > Setting optical loop OPEN
MasterDiagnostic_34788|INF| 29279|2023-10-10 20:57:46.338364| MAIN > Optical loop set to 0 ...

restart masterdiagnotcs.

ocam not live.

restart the bcu2k

home pupil rotator.

rotation same issue with the rotation. skip frames at ~40 degrees off.

Loop open

2:19PM

restart the AOAR

bin1.

moving backward/rofwatd

OK

bin2.

  • again problem to execute a full rotation.rot 320 degrees skip frames.
  • camera lens was tracking.
  • fringes. it seems that it is not rotating the pupil rerotatlr.
restart the AOAR.

..

pupil fringes for Bin2, to checked the pupil rerotation for Bin1 also, offset maybe not correct.?

check rotation 0->pupil rerot 350.223

forward 2

3:30PM

StopAO

-- JuanCarlosGuerra - 10 Oct 2023
Topic revision: r2 - 10 Oct 2023, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.