Details.

Power on WFS

09:30am

2 16:41:57.636070| MAIN > Maximum mode index used to apply flat -> # 639

ocam ok

09:58am

close loop + dist0.75"

Stable, good correction.slopSR:85,TN:_20231002_170336,_170528

pause/resume

launched the ocamviewer from script.

>ocamview_with_log

TN:_171126

open loop

preset.

2023-10-02 17:19:04 Waiting for pixels...
2023-10-02 17:19:04 Waiting for pixels...
2023-10-02 17:19:04 Waiting for pixels...
2023-10-02 17:19:04 Waiting for pixels...
2023-10-02 17:19:04 Reading shared buffer masterdiagnostic.L:OPTLOOPBUF - TIMEOUT_ERROR

this TIMEOUT_ERROR comes from the change in the ocam conf. from 1700 to 200

change to bin2

when loop closed.

2023-10-02 17:38:42 Reading shared buffer masterdiagnostic.L:OPTLOOPBUF - TIMEOUT_ERROR
2023-10-02 17:38:42 Setting background /home/sxwunit/live/aoroot/calib/wfs/current/ocam2/backgrounds/mode3/20231002_173840.fits
2023-10-02 17:38:42 Warning: no LUT hdu found!
2023-10-02 17:38:42 Waiting for pixels...
2023-10-02 17:38:42 Waiting for pixels...
2023-10-02 17:38:42 Waiting for pixels...

check flux.

back to 1500Hz.

TN:_174340

loop open.

check.

hexapod leg#4 following error.

preset mag 12.8

Tn:-175608

-- JuanCarlosGuerra - 02 Oct 2023
Topic revision: r1 - 02 Oct 2023, JuanCarlosGuerra