Staff:

LBTO:Juan Carlos

Observer.

Summary.

Two tasks. system check on Soul-luciSX+pupil wobble check

Soul-LBTIDX close loop with "patch" slope zero running.

The first task gave an error of fastlink and the second task closed the loop and it was accumulating close loop time.

Details.

12:00

Power on Soul-LuciSX.

timeout CCD47.

repeat Operate.

sArbitrator_178367|INF| 157|2023-09-23 19:17:17.562693| MAIN > Turning on LJ47_POWER
WfsArbitrator_178367|INF| 158|2023-09-23 19:17:47.563547| MAIN > Timeout waiting for ccd47.L.STATUS - TIMEOUT_ERROR
WfsArbitrator_178367|ERR| 159|2023-09-23 19:17:47.563666| MAIN > Exception: Timeout waiting for ccd47.L.STATUS
WfsArbitrator_178367|ERR| 160|2023-09-23 19:17:47.563734| MAIN > Timeout waiting for ccd47.L.STATUS (-5001) TI

Power cycle two tmes the CCD47 power.

Connected.

Finished the power on.

Ocam OK.

Chamber temperature 11.9C

deploy argos swing arm left.

Sat Sep 23 19:35:04.099 2023 OSS:sx.swa:selectArmAR: RPC: running.
Sat Sep 23 19:35:04.325 2023 OSS:sx.swa:selectArmAR: RPC: OK, CMD: success.
Sat Sep 23 19:35:31.818 2023 OSS:sx.swa:deployArmAR: RPC: running.
Sat Sep 23 19:35:33.839 2023 OSS:sx.swa:controlARLight: RPC: running.
Sat Sep 23 19:35:34.699 2023 OSS:sx.swa:deployArmAR: RPC: OK, CMD: success.
Sat Sep 23 19:35:34.832 2023 OSS:sx.swa:controlARLight: RPC: OK, CMD: success.

OSS commands didn;t work.

Deploy using Argos interface. White light source also didn;t work with OSS.

Set flat.

23 19:45:15.643369| MAIN > Maximum mode index used to apply flat -> # 499

TEST PRESET.

Sat Sep 23 19:49:09.076 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[93] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:-0.1[-0.1],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

FOUND PSF.

hexapod positions.

ocam not live at close loop.

change binning to restart bcu2k.

ocam live.

center pupils.

wfsarb offline

WfsArbitrator _6683 |INF| 120|2023-09-23 20:02:06.563135| MAIN > Received cmd: centerPupils()
WfsArbitrator_6683 |INF| 121|2023-09-23 20:02:06.563234| COMMANDHANDLER > FSM (status: AOSet) has received command 2039 (centerPupils)
WfsArbitrator_6683 |ERR| 122|2023-09-23 20:02:06.563258| COMMANDHANDLER > wfsarb: Fsm is discarding command 2039 (centerPupils)...
WfsArbitrator_6683 |WAR| 123|2023-09-23 20:02:06.563307| MAIN > centerPupils: WARNING - wfsarb:Illegal command for state AOSet (centerPupils)
WfsArbitrator_6683 |INF| 124|2023-09-23 20:02:09.916143| WFS > Command returns success .

process wfsarb doesn;t come up.

w_stop/start_all

wfsarb...ok

presetAO from AOS.

Sat Sep 23 20:07:44.445 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[95] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:-0.1[-0.1],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

center pupil. ocam not live.

power cycle bcu2k.

Sat Sep 23 20:13:33.512 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[97] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:-0.1[-0.1],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

power cycle masterdiagnostic process.

Sat Sep 23 20:16:32.697 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[99] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:-0.1[-0.1],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

ocam not live when the loop is closed.

powerr cycle bcu2k

Sat Sep 23 20:19:36.352 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[101] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:-0.1[-0.1],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

ocam not lve in close loop.

adsc stop and software restart.

wfs stop/all_all

flat.

|2023-09-23 20:28:01.158112| MAIN > Maximum mode index used to apply flat -> # 639

Sat Sep 23 20:30:27.235 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[103] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:-0.1[-0.1],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

ocam not live in close loop.

power cycle bcu2k.

Sat Sep 23 20:35:30.206 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[105] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:-0.1[-0.1],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

ocam not live the fastlink is not working.

FASTLINK NOT COMMUNICATING.

stop here..

adsecsx rest.

Ocam rest.

moving to test lbtiDX

1:48pm

shark team needs access to chamber light on

Power on LBTI-DX.

starting slope zero test.

waiting for tour to finish and shark-vis checks. shark-vis can work with lower lights on, I can proceed wth that.

handover 3:20PM

2:36 RESTART.

SET FLAT.

09-23 21:36:31.373079| MAIN > Maximum mode index used to apply flat -> # 621

close loop OK.

no oscillation, it seems same as before.

Sat Sep 23 21:51:44.946 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[84] (aomode:ACE-AO,focst:bentGregorianCenter,instr:LBTI,wfs:LBTIWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Sat Sep 23 21:51:44.961 2023 aos.info - WFS source set to: LBTIWFS
Sat Sep 23 21:51:45.019 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1700.00_sd3892.fits
Sat Sep 23 21:51:46.138 2023 aos.info - FLAO: WFS: loading setup for LBTI

optimize.20230923_215430

2.24,0.56,0.55

gopt

TN:#20230923_215621,_215716,_215727

slopeSR:83

all good.

stopAO

Sat Sep 23 22:00:20.780 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[88] (aomode:ACE-AO,focst:bentGregorianCenter,instr:LBTI,wfs:LBTIWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Sat Sep 23 22:00:20.796 2023 aos.info - WFS source set to: LBTIWFS
Sat Sep 23 22:00:20.849 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1200.00_sd3892.fits
Sat Sep 23 22:00:21.631 2023 aos.info - FLAO: WFS: loading setup for LBTI

optimize:220223

2.21,0.56,0.55

TN:220354,_2204,220433,_220454.

sloperms:1.3

modalSR 83

stopAO ok.

error after the stopAO
WfsArbitrator_23976|DEB| 473|2023-09-23 22:10:27.447407| MAIN > arbFunc updateNcpaInternal (, 'LBTIWFS', 'LBTI', 0, 1)
WfsArbitrator_23976|DEB| 474|2023-09-23 22:10:27.535962| MAIN > arbFunc updateNcpaInternal done.
WfsArbitrator_23975|ERR| 978|2023-09-23 22:10:39.525203| MAIN > OCAM Bad Frames/Slopes Error, code 2
WfsArbitrator_23975|ERR| 979|2023-09-23 22:10:39.525265| MAIN > OCAM Error Description: Code 2 - Slopes are all 0
WfsArbitrator_23975|ERR| 980|2023-09-23 22:10:39.525310| MAIN > OCAM Suggested action to recover: Change Bin back and forth via WFS control GUI; if required, power cycle BCU2k

3:13

[dxwunit@lbti-dxwfs source]$ use_soul
Usage: use_soul [version]
Currently running: stable (soul)
Available versions in /home/dxwunit/soul:
failed.20230304
master-and-fwFix
stable
stable.20211124
stable.20221117
stable.20230403
test.20230310.ncpa-threshold
test.20230615.sc-firmware-and-ocam-monitoring
test.20230923.zero-slope-firmware
[dxwunit@lbti-dxwfs source]$

Sat Sep 23 22:18:15.298 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[92] (aomode:ACE-AO,focst:bentGregorianCenter,instr:LBTI,wfs:LBTIWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Sat Sep 23 22:18:15.312 2023 aos.info - WFS source set to: LBTIWFS
Sat Sep 23 22:18:15.371 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq500.00_sd3892.fits

stopAO. Not time to proceed.

parked argos cal unit

3:32

handover to telescope

-- JuanCarlosGuerra - 23 Sep 2023
Topic revision: r4 - 26 Sep 2023, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.