Details.

10:30am

Power on WFs

t Sep 16 17:52:42.624 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[679] (aomode:ACE-AO,focst:bentGregorianCenter,instr:LBTI,wfs:LBTIWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Sat Sep 16 17:52:42.640 2023 aos.info - WFS source set to: LBTIWFS
Sat Sep 16 17:52:42.680 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.6_L040.0_v15.0_ovfreq1700.00_sd3892.fits

set flat, error.

idl_127294 |INF| 2597|2023-09-16 17:54:13.415517| MAIN > No gap contamination found.
idl_127294 |INF| 2598|2023-09-16 17:54:13.415734| MAIN > Dust test successfully completed
idl_127294 |INF| 2599|2023-09-16 17:54:13.415895| MAIN > Update progress successfully completed (2)
idl_127294 |INF| 2600|2023-09-16 17:54:13.416041| MAIN > FSM Rip done.
AdSecArbitrator_127411|ERR| 79298|2023-09-16 17:54:13.433335| IDL > Command returns error : IDL Ramp gain error: something is not going well (mirror stuck, gain too high...)
20231609 17:54:13.4338 Alert: Warning: setFlatAo failed or syntax error occured
AdSecArbitrator_127411|INF| 79299|2023-09-16 17:54:13.433612| COMMANDHANDLER > Command execution failed: Fsm forced to Failure
AdSecArbitrator_127411|ERR| 79300|2023-09-16 17:54:13.433752| MAIN > SetFlatAo: FATAL - IDL Ramp gain error: something is not going well (mirror stuck, gain too high...)
20231609 17:54:35.6106 Alert: HighOrderOffload: HighOrderOffload vector ready
20231609 17:54:55.7723 Alert: HighOrderOffload: HighOrderOffload vector ready
20231609 17:55:15.9925 Alert: HighOrderOffload: HighOrderOffload vector ready

adsc-stop/start.

After the adsc_stop/start the adsec arbtrator gui didnl;t show the option to power on.

Adsc arbitrator off/on

The gui shows the power on options.

8:03:16.133039| MAIN > Maximum mode index used to apply flat -> # 621

Test preset OK.

Cancel preset.

at Sep 16 18:05:18.674 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[682] (aomode:ACE-AO,focst:bentGregorianCenter,instr:LBTI,wfs:LBTIWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Sat Sep 16 18:05:18.692 2023 aos.info - WFS source set to: LBTIWFS

cancel preset.

align PSF in pyramid

Sat Sep 16 18:13:03.241 2023 aos.PresetAO{FLAO}.complete - PresetAO{FLAO}[684] - dx:nan dy:nan slNull: f1:1.0 f2:1.0 freq:1700 mag:0 nBins:1 nModes:500 r0:nan snMode:0 strehl:0 ttMod:0

Optmize gain:20230916_181656

1.79,0.54,0.53

gopt

modalSR 86

TN:20230916_182147,_182207,_182226

slopes rms 1.3

Sat Sep 16 18:26:35.009 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[688] (aomode:ACE-AO,focst:bentGregorianCenter,instr:LBTI,wfs:LBTIWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:12.8,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

shutter:115

mag 12.6

ptmize:_182942

1.38,0.48,0.69

TN:_183140,_183159,_183243

modalSR 80

slopesrms:1.35

Sat Sep 16 18:37:38.751 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[692] (aomode:ACE-AO,focst:bentGregorianCenter,instr:LBTI,wfs:LBTIWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:14.6,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

shutter:95

mag 14.7

optimize:_184019

1.88,1.26,0.10

TN:_184242,_184255,_184307,_184318,_184337(+ccd47)

modalSR 50

Sat Sep 16 18:46:56.870 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[696] (aomode:ACE-AO,focst:bentGregorianCenter,instr:LBTI,wfs:LBTIWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.6,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

shutter:81

mag: 16.5

Optimize:184933

0.77,0.94,0.10

TN:185123,_185148,_185204

slopeSR10

slopesrms4.38

11:53

StopAO

12:00pm

ocam set safe

-- JuanCarlosGuerra - 16 Sep 2023
Topic revision: r1 - 16 Sep 2023, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback