Staff.

LBTO: Juan Carlos.

Summary.

  • Found the PSF wth a new hexapod positions.
  • Bin1 Close loop with and without disturbance.
  • Loop stable. Only close loop for Bin1. with Gopt on SR from slopes ~83% looking at the auxloop plot.
  • Acquire TN with disturbance for Elab analysis.

Details.

1:11PM

WFS startup.

Bayside stage timeout.
  • Power cycle 24v.
  • Init bayside stages.
  • Operate.
Set Flat from AOS.
  • 20:28:36.956523| MAIN > Maximum mode index used to apply flat -> # 621
Argos cal unit deployed from Argos Interface.

OSS reports the correct status.

Chamber temp 18.7 degrees celcius

CCD47 hung.

TV dark.

20:32:47.056597| MAIN > calibTVDarkInternal(): starting measure, 10 frames
WfsArbitrator_84032|ERR| 193|2023-09-10 20:35:39.250831| MAIN > Reading shared buffer mirrorctrl.R:TECHVIEWER_65536 (-5001) TIMEOUT_ERROR
  • Change to bin16x16, viewer back....

01:38PM

PresetaO.

OK.

No star in the CCE47.

Scanning the field moving Rx and Ry.

No star found.

Better to go hexa spiral.

Cancel preset.

Preset again.

2:05PM

hexa_spiral

IDL> @startup-onlycom
IDL> print, hexa_spiral(500e-6, 15, /app)

Break process seems a glance of some changes in the CCD47 background, it could be the defocus PSF. Adjust position to Rx=0, Ry=100

IDL> @startup-onlycom
IDL> print, hexa_spiral(500e-6, 10 /app)

Found PSF

Hexapod position:

-4.15,-3.21, 0.47 7 159,-0

Close loop process.

close loop Gopt on.

TN:20230910_215138,215255

stopAO

The application of the flat gave #548 modes.

preset+disturbance.

Sun Sep 10 21:55:23.850 2023 aos.info - Updated variable AOARB.R.RR_ENABLED: 1
Sun Sep 10 21:56:31.680 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[493] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Sun Sep 10 21:56:31.693 2023 aos.info - WFS source set to: FLAOWFS
Sun Sep 10 21:56:31.741 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1700.00_sd3892.fits

TN:_220209,_220240,_220252

Hexapod positions:

hexapod_pos_dx_afterstopao.png

3:04PM

StopAO

-- JuanCarlosGuerra - 10 Sep 2023