Summary.

Details.

Guido did some test with the thin shell prior to the work with LBTIO close loop.

09:30 am

Power on.

w_start_all

[dxwunit@lbti-dxwfs source]$ w_check

msgdrtdb running
mirrorctrl running and connected to Msgd
pinger running and connected to Msgd
slopecompctrl running and connected to Msgd
techviewctrl running and connected to Msgd
ocam2 running and connected to Msgd
ccd47 running and connected to Msgd
ttctrl running and connected to Msgd
adc1 running and connected to Msgd
adc2 running and connected to Msgd
filterwheel1 running and connected to Msgd
filterwheel2 running and connected to Msgd
mercury running and connected to Msgd
cubestage running and connected to Msgd
baysidex running and connected to Msgd
baysidey running and connected to Msgd
baysidez running and connected to Msgd
cameralensctrl running and connected to Msgd
optloopdiag running and connected to Msgd
pupilcheckocam2 running and connected to Msgd
masterdiagnostic running and connected to Msgd
housekeeperWFS NOT running
dbfiller running and connected to Msgd
wfsarb NOT running
od_gopt NOT running
gopt NOT running
[dxwunit@lbti-dxwfs source]$

try again

OK.

09:41 power on.

adsec flat.

6-18 16:44:30.339833| MAIN > Maximum mode index used to apply flat -> # 622

ocam ok

n 18 16:54:51.445 2023 aos.warning - FLAO: Error for Variable: AOException: Error writing variable - -5001: Timeout error
Sun Jun 18 16:59:04.210 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[8900] (aomode:ACE-AO,focst:bentGregorianCenter,instr:LBTI,wfs:LBTIWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:12.5,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Sun Jun 18 16:59:04.228 2023 aos.info - WFS source set to: LBTIWFS
Sun Jun 18 16:59:04.275 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq750.00_sd3892.fits

Optmize:20230618_170316

TT3.03,0.86,0.5

adsec in continous dumping/skipping.

TN:20230618_170604,_170623,_170639,_170653,_170707,_170722,_170757,_170817

Check bin2 pupils

Sun Jun 18 17:10:19.305 2023 aos.AcquireRef{FLAO}.started - AcquireRef {FLAO}[8905] Mode: Move stages, Automatic acquire

there is a diffY=1.02, camera lens +100 in Y axe.

>>> makePupils.movePupils('20220505_181921',1,0,240,3)
makePupils_fromMasks(): moving from /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode3/pupdata.txt to /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode3/20230618_171851/pupdata.txt
/bin/mv -f "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode3/pupdata.txt" "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode3/20230618_171851/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 328
out_of_pupil_slopes 2192
lines_to_add 10
residual_pixels_to_add 8
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode3 to /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode3/20230618_171851
/bin/mv -f "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode3/pup1.fits" "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode3/20230618_171851"
1"
'20230618_171851'

test shift.

shift good.

shift_b2_20230618.png

Check Bin3.

diff y around 0.35 with Y +100

>>> makePupils.movePupils('20221012_164814',1,0,240,4)
makePupils_fromMasks(): moving from /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode4/pupdata.txt to /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode4/20230618_174135/pupdata.txt
/bin/mv -f "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode4/pupdata.txt" "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode4/20230618_174135/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 148
out_of_pupil_slopes 2552
lines_to_add 11
residual_pixels_to_add 38
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode4 to /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode4/20230618_174135
/bin/mv -f "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode4/pup1.fits" "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode4/20230618_174135"
'20230618_174135'

offsetbn3X 1

test pupil.

shift_b3_20230618.png

Check Bn4.

pupil_b4_beforeshift_20230618.png

diffX +0.25 camera lens axeX +100

generated a pupil :#5 can be removed from the directory.

>>> makePupils.movePupils('20200916_173857',0,1,240,5)
makePupils_fromMasks(): moving from /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt to /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20230618_180022/pupdata.txt
/bin/mv -f "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt" "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20230618_180022/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 80
out_of_pupil_slopes 2688
lines_to_add 12
residual_pixels_to_add 12
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5 to /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20230618_180022
/bin/mv -f "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pup1.fits" "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20230618_180022"
'20230618_180022

position to much to to X+

>>> makePupils.movePupils('20200916_173857',0,-1,240,5)
makePupils_fromMasks(): moving from /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt to /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20230618_180234/pupdata.txt
/bin/mv -f "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt" "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20230618_180234/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 80
out_of_pupil_slopes 2688
lines_to_add 12
residual_pixels_to_add 12
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5 to /home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20230618_180234
/bin/mv -f "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pup1.fits" "/home/dxwunit/liv

/bin/mv -f "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pup1.fits" "/home/dxwunit/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20230618_180234"
'20230618_180234'

test '20230618_180234'

camera lens more in middle range.

shift_b4_20230618.png

mag 12.5 seeing 0.7, low flux

Sun Jun 18 18:10:09.069 2023 aos.AcquireRef{FLAO}.complete - AcquireRef {FLAO}[8911] - dx:0 dy:0 slNull: f1:1.0 f2:1.0 freq:312 mag:0 nBins:4 nModes:54 r0:nan snMode:0 strehl:0 ttMod:0
Sun Jun 18 18:10:19.060 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[8912] (aomode:ACE-AO,focst:bentGregorianCenter,instr:LBTI,wfs:LBTIWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:12.5,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Sun Jun 18 18:10:19.078 2023 aos.info - WFS source set to: LBTIWFS
Sun Jun 18 18:10:19.136 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq750.00_sd3892.fits

optimize:181250

TT 2.06,0.74,0.39

TN:_181711,_181743,_181805,_181823,_181856,_

TT residual a bit high, one click TT improved.

optimize: 182105

TT:2.62,0.74,0.47

much better performances.

TB:_182401,_182416,_182430,_182445,_182501,_182553

mag 11 seeing 0.7, low flux

Sun Jun 18 18:27:34.478 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[8916] (aomode:ACE-AO,focst:bentGregorianCenter,instr:LBTI,wfs:LBTIWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Sun Jun 18 18:27:34.494 2023 aos.info - WFS source set to: LBTIWFS
Sun Jun 18 18:27:34.548 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1200.00_sd3892.fits

optimize:

1.18,0.39,0.34

TN:183506,_183522,_183537,_183548,_183602,_183613,_183626

one click TT improve perf.

TN:_183816,_183830,_183843,_183931,_183946,_183957


mag 11 seeing 1

Sun Jun 18 18:41:05.067 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[8920] (aomode:ACE-AO,focst:bentGregorianCenter,instr:LBTI,wfs:LBTIWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Sun Jun 18 18:41:05.084 2023 aos.info - WFS source set to: LBTIWFS
Sun Jun 18 18:41:05.323 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq1200.00_sd3892.fits

Optimize:

second optimize failed second pass TT. skip frames.

third try:185025

1.18

higher TT residual.

TN:_185226,_185239,_185325,_185358

performances low, tt residual above 10mas.

understood. source low. 1.9phot/subap

]optimize.

TN:_185647,_185658,_185708,_185721,_185736,_185759,_185811

mag 11 seeing 0.7

Sun Jun 18 19:00:08.349 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[8925] (aomode:ACE-AO,focst:bentGregorianCenter,instr:LBTI,wfs:LBTIWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Sun Jun 18 19:00:08.367 2023 aos.info - WFS source set to: LBTIWFS
Sun Jun 18 19:00:08.424 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq900.00_sd3892.fits

Optimize:190201

TT 2.27,0.55,0.37

TN:_190359,_190420,_190433,_190448,_190518,_190545,_190558

1206PM

STOP

park.

ocam safe

adsec rest

-- JuanCarlosGuerra - 18 Jun 2023
Topic revision: r2 - 19 Jun 2023, JuanCarlosGuerra